Juniper Networks 5000 SERIES manual General Installation Guidelines

Page 22

Chapter 2 Installing the Device

GENERAL INSTALLATION GUIDELINES

Observing the following precautions can prevent injuries, equipment failures, and shutdowns.

Never assume that the power supply is disconnected from a power source. Always check first.

Room temperature might not be sufficient to keep equipment at acceptable temperatures without an additional circulation system. Ensure that the room in which you operate the NetScreen-5000 Series has adequate air circulation.

Do not work alone if potentially hazardous conditions exist.

Look carefully for possible hazards in your work area, such as moist floors, ungrounded power extension cables, frayed power cords, and missing safety grounds.

Important: Although you can place the NetScreen-5000 Series on a desktop for operation, NetScreen does not recommend deploying it in this manner.

Warning: To prevent abuse and intrusion by unauthorized personnel, it is extremely important to install the NetScreen device in a locked-room environment.

EQUIPMENT RACK INSTALLATION GUIDELINES

The location of the chassis and the layout of your equipment rack or wiring room are crucial for proper system operation.

Use the following guidelines while configuring your equipment rack.

Enclosed racks must have adequate ventilation. An enclosed rack should have louvered sides and a fan to provide cooling air.

When mounting a chassis in an open rack, ensure that the rack frame does not block the intake or exhaust ports. If you install the chassis on slides, check the position of the chassis when it is seated all the way into the rack.

In an enclosed rack with a ventilation fan in the top, equipment higher in the rack can draw heat from the lower devices. Always provide adequate ventilation for equipment at the bottom of the rack.

Baffles can isolate exhaust air from intake air. The best placement of the baffles depends on the airflow patterns in the rack.

You can mount the device in a standard 19-inch equipment rack. Rack mounting requires the following tools:

1 Phillips-head screwdriver

Rack-compatible screws

The included rear slide kit (for the rear and front mount method) on the NetScreen-5200

Front-mount brackets

14

User’s Guide

Image 22
Contents NETSCREEN-5000 Series Copyright Notice Language Contents Language Contents Table of Contents Servicing the Device Index Table of Contents Viii Preface Guide OrganizationSet admin user name1 password xyz Command Line Interface CLI ConventionsJuniper Networks Netscreen Publications Overview1 NetScreen-5400 NetScreen-5200NETSCREEN-5000 Series Power Supplies NetScreen-5400 Power Recommendations NetScreen-5200 Power RecommendationsDC Power Supply AC Power Supply FAN ModulesNETSCREEN-5000 Modules Management Modules5000-M Management Module 5000-M2 Management Module NetScreen-5000 ModulesSecure Port Modules 5000-8G SPM 5000-2G24FE SPM Overview User’s Guide Installing the Device General Installation Guidelines Equipment Rack Installation GuidelinesNetScreen-5200 Front and Rear Mount Mounting the NETSCREEN-5000 SeriesNetScreen-5200 Mid-Mount NetScreen-5400 Front MountInstalling and Connecting the AC Power Supply Installing and Wiring a DC Power Supply48V COMThumbscrew Power Connecting the NETSCREEN-5000 Series to a Router or Switch Establishing AN HA ConnectionInstalling the Device User’s Guide Configuring the Device Route Mode Transparent ModeOperational Modes NetScreen-5200 Interfaces NETSCREEN-5000 InterfacesConfigurable Interfaces NetScreen-5400 InterfacesPerforming Initial Connection and Configuration Establishing a Terminal Emulator ConnectionUpgrading the Firmware During the Boot Process Viewing Current Interface Settings Changing Your Admin Name and PasswordSetting Port and Interface IP Addresses Setting the IP Address of the Management InterfaceSetting the IP Address for the Trust Zone Interface Setting the IP Address for the Untrust Zone InterfaceConfiguring the Device for Telnet and Webui Sessions Starting a Console Session Using TelnetAllowing Outbound Traffic Establishing a GUI Management Session Starting a Console Session Using DialupTelnet Http//10.100.2.183 Configuring the Chassis AlarmGet chassis Set interface string zone zonename Configuring Aggregate InterfacesGet interface Get interface aggregate1 Using CLI Commands to Reset the Device Following CLI command unset admin device-resetPress the y key Following message appears Servicing the Device Replacing a DC Power Supply Removing and Reseating ModulesReplacing AN AC Power Supply Replacing the FAN TrayConnecting and Disconnecting Gigabit Ethernet Cables Removing and Installing a MINI-GBIC Transceiver Servicing the Device User’s Guide Specifications NETSCREEN-5200 Attributes Electrical SpecificationEnvironmental Specification NETSCREEN-5400 AttributesNebs Certifications Safety CertificationsConnectors EMI CertificationsAppendix a Specifications User’s Guide Port Descriptions and LED Status B Module Port Descriptions MGTModule LED Descriptions Interpreting Status LEDs for the Management ModulesStatus LED States Interpreting Status LEDs for the Secure Port Module Interpreting Ethernet Port Status LEDs for All ModulesPower Supply Leds Interpreting Power Supply LED Status for the NetScreen-5200Interpreting Power Supply LED Status for the NetScreen-5400 Single SPM InstalledFAN LED Index User’s Guide Table des matières Chapitre Entretien de l’unité Index 103 Table des matières Xii Manuel de l’utilisateur Préface Organisation DU ManuelSet admin user nom1 password xyz Publications Juniper Networks NetscreenPrésentation générale Unité NetScreen-5400 Unité NetScreen-5200Série DE Produits NETSCREEN-5000 Blocs D’ALIMENTATION Bloc d’alimentation CC DELBloc d’alimentation CA Modules DE VentilationModules NETSCREEN-5000 Modules de gestionModule de gestion 5000-M Module de gestion 5000-M2 Modules NetScreen-5000Modules de ports sécurisés SPM 5000-8GSPM 5000-2G24FE Chapitre 1 Présentation générale Manuel de l’utilisateur Installation de l’unité Instructions D’INSTALLATION Générales Instructions D’INSTALLATION DE LA Baie DE ÉquipementMontage avant et arrière de l’unité NetScreen-5200 Montage DE L’UNITÉ DE LA Série NETSCREEN-5000Montage à mi-hauteur de l’unité NetScreen-5200 Montage frontal de l’unité NetScreen-5400Installation ET Connexion DU Bloc Dalimentation CA Installation ET Raccordement D’UN Bloc ’ALIMENTATION CDCOM Établissement D’UNE Connexion HA Chapitre 2 Installation de l’unité Manuel de l’utilisateur Configuration de l’unité Mode Route Mode TransparentModes DE Fonctionnement Interfaces NetScreen-5200 Interfaces NETSCREEN-5000Interfaces configurables Interfaces NetScreen-5400Exécution DE LA Connexion ET DE LA Configuration Initiales Établissement d’une connexion d’émulateur de terminalChapitre 3 Configuration de l’unité Affichage des paramètres d’interface actuels Configuration des adresses IP de port et d’interfaceConfiguration de l’adresse IP de l’interface de gestion Set interface mgt ip adrip/masqueSet interface ethernet2/2 ip adrip/masque Get interface mgtGet interface ethernet2/2 Autorisation du trafic sortant Démarrage d’une session de console à l’aide de TelnetSet interface ethernet2/3 ip adrip/masque Telnet Configuration DE L’ALARME DE Châssis Configuration D’INTERFACES Agrégées Set interface chaîne zone nomdelazoneSérie de produits NetScreen-5000 Appuyez sur la touche y Le message suivant s’affiche Entretien de l’unité Retrait ET Réinstallation DES Modules Remplacement D’UN Bloc D’ALIMENTATION CCRemplacement D’UN Bloc D’ALIMENTATION CA Remplacement DU Bloc DE VentilationConnexion ET Déconnexion DES Câbles Gigabit Ethernet Retrait ET Installation D’UN Transmetteur MINI-GBIC Chapitre 4 Entretien de l’unité Manuel de l’utilisateur SpécificationsA Spécifications Électriques Attributs DE L’UNITÉ NETSCREEN-5200Attributs DE L’UNITÉ NETSCREEN-5400 Spécifications EnvironnementalesCertifications EMI Certifications NebsCertifications DE Conformité ConnecteursAnnexe a Spécifications Manuel de l’utilisateur Série de produits NetScreen-5000 Description DES Ports DES Modules Description DES DEL DES Modules Interprétation des DEL d’état des modules de gestionEtats DES DEL D’ÉTAT Interprétation des DEL d’état des modules de ports sécurisés Un seul SPM installé DEL DES Blocs D’ALIMENTATIONDEL DE Ventilation FAN Nombres 104 Manuel de l’utilisateur