Juniper Networks 5000 SERIES manual Upgrading the Firmware During the Boot Process

Page 34

Chapter 3 Configuring the Device

Upgrading the Firmware During the Boot Process

1.Connect your computer to the NetScreen-5000 Series device:

a.Using a serial cable, connect the serial port on your computer to the console port on the NetScreen-5000 Series device. This connection, in combination with a terminal application, enables you to manage the NetScreen device.

b.Using an Ethernet cable, connect the network port on your computer to the management port on the NetScreen-5000 Series device. This connection enables the transfer of data between the computer, the TFTP server, and the NetScreen device.

2.Make sure that you have the new ScreenOS image file stored in the TFTP server directory on your computer. For information on obtaining the new firmware, see the NetScreen Concepts & Examples Reference Guide.

3.Run the TFTP server on your computer by double-clicking on the TFTP server application. You can minimize its window but it must be active in the background.

4.Log in to the NetScreen-5000 Series device using a terminal emulator such as HyperTerminal. See “Establishing a Terminal Emulator Connection” on page 25. Log in as the root admin or an admin with read-write privileges.

5.Power on or restart the NetScreen-5000 Series device.

6.Keep your eyes on the terminal emulator screen, then when you see “Hit any key to run loader”, press any key on your computer keyboard to interrupt the startup.

Note: If you do not interrupt the NetScreen-5000 Series device in time, it proceeds to load the firmware saved in flash memory.

7.At the Boot File Name prompt, enter the file name of the ScreenOS firmware you want to load.

8.At the Self IP Address prompt, enter the IP address of the NetScreen-5000 Series device that is used to communicate to the TFTP server.

9.At the TFTP IP Address prompt, enter the IP address of the TFTP server.

An indication that the firmware is loading successfully is the display of the series of “rtatatatatata...” running on the terminal emulator screen and a series of symbols running on the TFTP server window. When the firmware installation is complete, a message informs you of the success of the installation.

10.Answer Yes to the following question: “Program to on-board flash” ([y]/n)” Answering “yes” saves the firmware you installed to flash memory.

11.Answer Yes to the following question: “Run downloaded program? ([y]/n)”

Answering “yes” instructs the NetScreen-5000 Series device to start running the new ScreenOS firmware.

26

User’s Guide

Image 34
Contents NETSCREEN-5000 Series Copyright Notice Language Contents Language Contents Table of Contents Servicing the Device Index Table of Contents Viii Preface Guide OrganizationSet admin user name1 password xyz Command Line Interface CLI ConventionsJuniper Networks Netscreen Publications Overview1 NetScreen-5400 NetScreen-5200NETSCREEN-5000 Series Power Supplies NetScreen-5400 Power Recommendations NetScreen-5200 Power RecommendationsDC Power Supply AC Power Supply FAN ModulesNETSCREEN-5000 Modules Management Modules5000-M Management Module 5000-M2 Management Module NetScreen-5000 ModulesSecure Port Modules 5000-8G SPM5000-2G24FE SPM Overview User’s Guide Installing the Device General Installation Guidelines Equipment Rack Installation GuidelinesNetScreen-5200 Front and Rear Mount Mounting the NETSCREEN-5000 SeriesNetScreen-5200 Mid-Mount NetScreen-5400 Front MountInstalling and Connecting the AC Power Supply Installing and Wiring a DC Power Supply48V COMThumbscrew Power Connecting the NETSCREEN-5000 Series to a Router or Switch Establishing AN HA ConnectionInstalling the Device User’s Guide Configuring the Device Route Mode Transparent ModeOperational Modes NetScreen-5200 Interfaces NETSCREEN-5000 InterfacesConfigurable Interfaces NetScreen-5400 InterfacesPerforming Initial Connection and Configuration Establishing a Terminal Emulator ConnectionUpgrading the Firmware During the Boot Process Viewing Current Interface Settings Changing Your Admin Name and PasswordSetting Port and Interface IP Addresses Setting the IP Address of the Management InterfaceSetting the IP Address for the Trust Zone Interface Setting the IP Address for the Untrust Zone InterfaceConfiguring the Device for Telnet and Webui Sessions Starting a Console Session Using TelnetAllowing Outbound Traffic Establishing a GUI Management Session Starting a Console Session Using DialupTelnet Http//10.100.2.183 Configuring the Chassis AlarmGet chassis Set interface string zone zonename Configuring Aggregate InterfacesGet interface Get interface aggregate1 Using CLI Commands to Reset the Device Following CLI command unset admin device-resetPress the y key Following message appears Servicing the Device Replacing a DC Power Supply Removing and Reseating ModulesReplacing AN AC Power Supply Replacing the FAN TrayConnecting and Disconnecting Gigabit Ethernet Cables Removing and Installing a MINI-GBIC Transceiver Servicing the Device User’s Guide Specifications NETSCREEN-5200 Attributes Electrical SpecificationEnvironmental Specification NETSCREEN-5400 AttributesNebs Certifications Safety CertificationsConnectors EMI CertificationsAppendix a Specifications User’s Guide Port Descriptions and LED Status B Module Port Descriptions MGTModule LED Descriptions Interpreting Status LEDs for the Management ModulesStatus LED States Interpreting Status LEDs for the Secure Port Module Interpreting Ethernet Port Status LEDs for All ModulesPower Supply Leds Interpreting Power Supply LED Status for the NetScreen-5200Interpreting Power Supply LED Status for the NetScreen-5400 Single SPM InstalledFAN LED Index User’s Guide Table des matières Chapitre Entretien de l’unité Index 103 Table des matières Xii Manuel de l’utilisateur Préface Organisation DU ManuelSet admin user nom1 password xyz Publications Juniper Networks NetscreenPrésentation générale Unité NetScreen-5400 Unité NetScreen-5200Série DE Produits NETSCREEN-5000 Blocs D’ALIMENTATION Bloc d’alimentation CC DELBloc d’alimentation CA Modules DE VentilationModules NETSCREEN-5000 Modules de gestionModule de gestion 5000-M Module de gestion 5000-M2 Modules NetScreen-5000Modules de ports sécurisés SPM 5000-8GSPM 5000-2G24FE Chapitre 1 Présentation générale Manuel de l’utilisateur Installation de l’unité Instructions D’INSTALLATION Générales Instructions D’INSTALLATION DE LA Baie DE ÉquipementMontage avant et arrière de l’unité NetScreen-5200 Montage DE L’UNITÉ DE LA Série NETSCREEN-5000Montage à mi-hauteur de l’unité NetScreen-5200 Montage frontal de l’unité NetScreen-5400Installation ET Connexion DU Bloc Dalimentation CA Installation ET Raccordement D’UN Bloc ’ALIMENTATION CDCOM Établissement D’UNE Connexion HA Chapitre 2 Installation de l’unité Manuel de l’utilisateur Configuration de l’unité Mode Route Mode TransparentModes DE Fonctionnement Interfaces NetScreen-5200 Interfaces NETSCREEN-5000Interfaces configurables Interfaces NetScreen-5400Exécution DE LA Connexion ET DE LA Configuration Initiales Établissement d’une connexion d’émulateur de terminalChapitre 3 Configuration de l’unité Affichage des paramètres d’interface actuels Configuration des adresses IP de port et d’interfaceConfiguration de l’adresse IP de l’interface de gestion Set interface mgt ip adrip/masqueSet interface ethernet2/2 ip adrip/masque Get interface mgtGet interface ethernet2/2 Autorisation du trafic sortant Démarrage d’une session de console à l’aide de TelnetSet interface ethernet2/3 ip adrip/masque Telnet Configuration DE L’ALARME DE Châssis Configuration D’INTERFACES Agrégées Set interface chaîne zone nomdelazoneSérie de produits NetScreen-5000 Appuyez sur la touche y Le message suivant s’affiche Entretien de l’unité Retrait ET Réinstallation DES Modules Remplacement D’UN Bloc D’ALIMENTATION CCRemplacement D’UN Bloc D’ALIMENTATION CA Remplacement DU Bloc DE VentilationConnexion ET Déconnexion DES Câbles Gigabit Ethernet Retrait ET Installation D’UN Transmetteur MINI-GBIC Chapitre 4 Entretien de l’unité Manuel de l’utilisateur SpécificationsA Spécifications Électriques Attributs DE L’UNITÉ NETSCREEN-5200Attributs DE L’UNITÉ NETSCREEN-5400 Spécifications EnvironnementalesCertifications EMI Certifications NebsCertifications DE Conformité ConnecteursAnnexe a Spécifications Manuel de l’utilisateur Série de produits NetScreen-5000 Description DES Ports DES Modules Description DES DEL DES Modules Interprétation des DEL d’état des modules de gestionEtats DES DEL D’ÉTAT Interprétation des DEL d’état des modules de ports sécurisés Un seul SPM installé DEL DES Blocs D’ALIMENTATIONDEL DE Ventilation FAN Nombres 104 Manuel de l’utilisateur