Juniper Networks 5000 SERIES Configuring Aggregate Interfaces, Set interface string zone zonename

Page 40

Chapter 3 Configuring the Device

CONFIGURING AGGREGATE INTERFACES

The NetScreen-5000 Series device allows you to combine two or more physical ports into a single virtual port. This virtual port is known as an aggregate interface. Only Secure Port Modules (SPMs) support this feature.

On a 5000-8G SPM, you can create up to four aggregate interfaces.

On a 5000-2G24FE SPM, you can create up to five aggregate interfaces.

The 5000-8G SPM supports only certain combinations of ports for aggregate interfaces. For example, a 5000-8G SPM residing in slot 2 only supports the following port combinations:

Ethernet2/1 and Ethernet2/2

Ethernet2/3 and Ethernet2/4

Ethernet2/5 and Ethernet2/6

Ethernet2/7 and Ethernet2/8

You must assign one of the following names to the aggregate interface: aggregate1, aggregate2, aggregate3, or aggregate4.

In the following example, you combine two Gigabit Ethernet mini-GBIC ports, each running at 1 Gbps, into an aggregate interface running at 2 Gbps. The aggregate interface consists of Ethernet ports 1 and 2 on a 5000-8G SPM (residing in slot 2).

To create the aggregate interface:

1.(Optional) To see what physical ports are available on your NetScreen-5000 Series device:

get interface

2.To create an aggregate interface name:

set interface string zone zonename

where string is a legal aggregate interface name (aggregate1, aggregate2, aggregate3, or aggregate4).

For example, to create the aggregate interface name aggregate1: set interface aggregate1 zone zonename

3.To assign ports ethernet2/1 and ethernet2/2 to the aggregate1 interface name:

set interface ethernet2/1 aggregate aggregate1 set interface ethernet2/2 aggregate aggregate1

4.(Optional) To see the updated port list and details about the new aggregate interface:

get interface

get interface aggregate1

32

User’s Guide

Image 40
Contents NETSCREEN-5000 Series Copyright Notice Language Contents Language Contents Table of Contents Servicing the Device Index Table of Contents Viii Preface Guide OrganizationSet admin user name1 password xyz Command Line Interface CLI ConventionsJuniper Networks Netscreen Publications Overview1 NetScreen-5400 NetScreen-5200NETSCREEN-5000 Series Power Supplies NetScreen-5400 Power Recommendations NetScreen-5200 Power RecommendationsDC Power Supply AC Power Supply FAN ModulesNETSCREEN-5000 Modules Management Modules5000-M Management Module 5000-M2 Management Module NetScreen-5000 ModulesSecure Port Modules 5000-8G SPM5000-2G24FE SPM Overview User’s Guide Installing the Device General Installation Guidelines Equipment Rack Installation GuidelinesNetScreen-5200 Front and Rear Mount Mounting the NETSCREEN-5000 SeriesNetScreen-5200 Mid-Mount NetScreen-5400 Front MountInstalling and Connecting the AC Power Supply Installing and Wiring a DC Power Supply48V COMThumbscrew Power Connecting the NETSCREEN-5000 Series to a Router or Switch Establishing AN HA ConnectionInstalling the Device User’s Guide Configuring the Device Route Mode Transparent ModeOperational Modes NetScreen-5200 Interfaces NETSCREEN-5000 InterfacesConfigurable Interfaces NetScreen-5400 InterfacesPerforming Initial Connection and Configuration Establishing a Terminal Emulator ConnectionUpgrading the Firmware During the Boot Process Changing Your Admin Name and Password Setting Port and Interface IP AddressesViewing Current Interface Settings Setting the IP Address of the Management InterfaceSetting the IP Address for the Trust Zone Interface Setting the IP Address for the Untrust Zone InterfaceConfiguring the Device for Telnet and Webui Sessions Starting a Console Session Using TelnetAllowing Outbound Traffic Establishing a GUI Management Session Starting a Console Session Using DialupTelnet Http//10.100.2.183 Configuring the Chassis AlarmGet chassis Set interface string zone zonename Configuring Aggregate InterfacesGet interface Get interface aggregate1 Using CLI Commands to Reset the Device Following CLI command unset admin device-resetPress the y key Following message appears Servicing the Device Replacing a DC Power Supply Removing and Reseating ModulesReplacing AN AC Power Supply Replacing the FAN TrayConnecting and Disconnecting Gigabit Ethernet Cables Removing and Installing a MINI-GBIC Transceiver Servicing the Device User’s Guide Specifications Electrical Specification Environmental SpecificationNETSCREEN-5200 Attributes NETSCREEN-5400 AttributesSafety Certifications ConnectorsNebs Certifications EMI CertificationsAppendix a Specifications User’s Guide Port Descriptions and LED Status B Module Port Descriptions MGTModule LED Descriptions Interpreting Status LEDs for the Management ModulesStatus LED States Interpreting Status LEDs for the Secure Port Module Interpreting Ethernet Port Status LEDs for All ModulesInterpreting Power Supply LED Status for the NetScreen-5200 Interpreting Power Supply LED Status for the NetScreen-5400Power Supply Leds Single SPM InstalledFAN LED Index User’s Guide Table des matières Chapitre Entretien de l’unité Index 103 Table des matières Xii Manuel de l’utilisateur Préface Organisation DU ManuelSet admin user nom1 password xyz Publications Juniper Networks NetscreenPrésentation générale Unité NetScreen-5400 Unité NetScreen-5200Série DE Produits NETSCREEN-5000 Blocs D’ALIMENTATION Bloc d’alimentation CC DELBloc d’alimentation CA Modules DE VentilationModules NETSCREEN-5000 Modules de gestionModule de gestion 5000-M Module de gestion 5000-M2 Modules NetScreen-5000Modules de ports sécurisés SPM 5000-8GSPM 5000-2G24FE Chapitre 1 Présentation générale Manuel de l’utilisateur Installation de l’unité Instructions D’INSTALLATION Générales Instructions D’INSTALLATION DE LA Baie DE ÉquipementMontage avant et arrière de l’unité NetScreen-5200 Montage DE L’UNITÉ DE LA Série NETSCREEN-5000Montage à mi-hauteur de l’unité NetScreen-5200 Montage frontal de l’unité NetScreen-5400Installation ET Connexion DU Bloc Dalimentation CA Installation ET Raccordement D’UN Bloc ’ALIMENTATION CDCOM Établissement D’UNE Connexion HA Chapitre 2 Installation de l’unité Manuel de l’utilisateur Configuration de l’unité Mode Route Mode TransparentModes DE Fonctionnement Interfaces NetScreen-5200 Interfaces NETSCREEN-5000Interfaces configurables Interfaces NetScreen-5400Exécution DE LA Connexion ET DE LA Configuration Initiales Établissement d’une connexion d’émulateur de terminalChapitre 3 Configuration de l’unité Configuration des adresses IP de port et d’interface Configuration de l’adresse IP de l’interface de gestionAffichage des paramètres d’interface actuels Set interface mgt ip adrip/masqueSet interface ethernet2/2 ip adrip/masque Get interface mgtGet interface ethernet2/2 Autorisation du trafic sortant Démarrage d’une session de console à l’aide de TelnetSet interface ethernet2/3 ip adrip/masque Telnet Configuration DE L’ALARME DE Châssis Configuration D’INTERFACES Agrégées Set interface chaîne zone nomdelazoneSérie de produits NetScreen-5000 Appuyez sur la touche y Le message suivant s’affiche Entretien de l’unité Retrait ET Réinstallation DES Modules Remplacement D’UN Bloc D’ALIMENTATION CCRemplacement D’UN Bloc D’ALIMENTATION CA Remplacement DU Bloc DE VentilationConnexion ET Déconnexion DES Câbles Gigabit Ethernet Retrait ET Installation D’UN Transmetteur MINI-GBIC Chapitre 4 Entretien de l’unité Manuel de l’utilisateur SpécificationsA Attributs DE L’UNITÉ NETSCREEN-5200 Attributs DE L’UNITÉ NETSCREEN-5400Spécifications Électriques Spécifications EnvironnementalesCertifications Nebs Certifications DE ConformitéCertifications EMI ConnecteursAnnexe a Spécifications Manuel de l’utilisateur Série de produits NetScreen-5000 Description DES Ports DES Modules Description DES DEL DES Modules Interprétation des DEL d’état des modules de gestionEtats DES DEL D’ÉTAT Interprétation des DEL d’état des modules de ports sécurisés Un seul SPM installé DEL DES Blocs D’ALIMENTATIONDEL DE Ventilation FAN Nombres 104 Manuel de l’utilisateur