GE ZBTSD manual Entelli-Switch 250 User Setup System Info, View System Data

Page 20

Entelli-Switch 250 User Setup - System Info

View System Data

Enter six digit access code

(The factory assigned six-digit access code is located on the back of the controller)

1

42

3

6

Engine Start Relay (De-Energized)

Network Communications (Option)

WARNING

1Controller Inputs must be relay Isolated.

A2

A1

RELAY

14

11

12

(-)

(+)

 

 

 

 

 

 

 

 

 

 

COM

J2

Customer

J2-3

InputN.O N.C

*

1

2

3

4

PROG 1

PROG 2

GRD (Input Sink)

LS OUT

Voltage

To

J2/J4

Inputs

5

6

7

NIA OUT

ELEV. PRE. OUT

ALARM OUT

2Controller Outputs have Limited Source Capacity. Use only GE Zenith-specified Output Modules.

11

14

12

A1

8

STE OUT

9

10

MOTOR DISC. OUT

 

 

 

R1

(+)

21

24

22

 

A2

 

(-)

 

 

 

 

11

12

13

14

15

16

TMS IN

INHIB.>S1

INHIB.>S2

LS IN

Output

 

 

 

 

 

Contacts

 

 

 

 

 

11

14

12

21

24

22

 

R1 Output

 

 

R1 Output

 

J4

*

*

Input and output availability

Contact Rating: 10A @ 250 VAC or 30 VDC

 

 

subject to factory configuration.

 

1

2

3+12v (Output Source)

4LN OUT

5L4 OUT

6

L3 OUT

Lithium Battery

Exerciser Battery

7

L2 OUT

 

Replacement-K-4100 (BR2032)

8

L1 OUT

 

Service Life-10 Years

 

† During normal operation

9

YN IN

 

 

10

YE IN

User Access Code

Default-121212

11

TSNL IN

 

 

12

Q2/TSL IN

PRODUCT INFORMATION

www.geindustrial.com

13

S12 IN

24-Hour Service

(773)299-6600

14

S5 IN

 

 

Entelli-Switch MX250TM

Figure 11

18

ZBTS / ZBTSD Operation and Maintenance Manual (71R-4000A)

GE Zenith Controls

 

Image 20 Contents
GE Zenith Controls Introduction Authorized ServiceTable of Contents Safety Equipment Inspection and StorageFinal Equipment Inspection MountingEngine Start Control Connections InstallationPower Connections Installation cont’d IInitial EnergizationInitial Energization cont’d R E T E S TInstallation cont’d Entelli-Switch 250 Controller Entelli-Switch 250 ControllerEntelli-Switch 250 Controller cont’d LCD & KeypadUser Setting for Voltage & Frequency Standard 3-Phase Sensing on 3 and 4 Pole Units SourceAccessory Group Packages Stds Exes Cons Sens Spes PsgsCalibrate Accessory DefinitionsA62 Accessory Definitions cont’d R50 S12PS13P S14How to Set the System Clock UMDCDT One Event Timer Exerciser Load / No-LoadCDP Clock Exerciser Load / No-Load Clock ExerciserEntelli-Switch 250 User Setup CFG Menu Turn options on or OFF via keypad through the CFG menuEntelli-Switch 250 User Setup SET Menu Change adjustable values through the SET menuEntelli-Switch 250 User Setup System Info View System DataTesting ATS TestingDelayed Transition Standard TransitionTimer Designations as they appear in the SET menu Sequence of OperationSequence of Operation cont’d Bypass-Isolation Operation100-400 AMP Automatic600-1200 AMP 1600-4000 AMP Controls Power Supply CPS Standard and Delay TransitionDelayed Transition CPS Schematic Controls Power Supply CPS cont’dStandard Transition CPS Schematic Troubleshooting and Diagnostics General TroubleshootingMaintenance and Testing Inspection and CleaningTesting ServicingPage GE Zenith Controls