GarrettCom 1008 Basic AUI port, Optional PM card, BPM shown, PM Ribbon cable with 16 pin headers

Page 14
2.3Internal Connections, basic AUI Port and Port Modules

Magnum 1000 Workgroup Hubs

Installation and User Guide (04/02)

2.3Internal Connections, basic AUI Port and Port Modules

Figure 2.3a shows the internal layout of the Magnum 1008 for each of the two

rear port configuration options (see section 2.2.1). Unless otherwise specified at the time of order, the Magnum 1008 is shipped with a basic AUI port. For greater application flexibility, any of the Magnum PMs may be specified at the time of order for factory configuration. It is also possible for the rear port to be re-configured in the field by a trained technician to exchange or add Port Modules.

NOTE: When changing from the basic AUI port to a Port Module option in the field, it is necessary to have a Port Module connector cable (part number CBL-PM available as a spare part from GCI) in addition to the desired PM.

Basic AUI port

 

 

 

 

 

 

 

 

 

 

Optional PM card

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(BPM shown)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P1-RPM

P1

P1-RPM

P1

NOTE:

Use P1 for Basic AUI port Use P1-RPM for PM

PM Ribbon cable with 16 pin headers.

(Included only when PM is factory installed. May be ordered separately as part # CBL-PM)

Figure 2.3a: Model 1008 Internal Connections, Basic AUI port and Port Module

Figure 2.3b shows the internal layout of the Magnum 1016 and 1024

Workgroup Hubs. (The Model 1024 is shown in the figure, but all rear port connections are identical for the Model 1016). One rear port always has the basic AUI port in it. The bonus port slot, in the center of the chassis rear, is available for configuring any PM. For application flexibility, any of the Magnum PMs may be specified on an order for factory configuration in the bonus port slot. It is also possible for the bonus port to be re-configured in the field by a trained technician to exchange or add Port Modules.

NOTE: When adding a Port Module option to the Bonus Port slot in the field, it is necessary to have a Port Module connector cable (part # CBL-PM available as a spare part from GCI) in addition to the desired PM. See also Section 2.4.12, Special Option.

www . GarrettCom . com

8

Image 14
Contents Magnum Workgroup Hubs “Ten Series” Models 1008, 1016 andInstallation and User Guide www . GarrettCom . comand optional 48VDC, 24VDC &125VDC-powered models Workgroup Hubs Installation and User GuideMagnum 1008, 1016 and Installation and User Guide 04/02Phone 510 GarrettCom, Inc47823 Westinghouse Drive Fremont, CA Fax 510Page APPENDIX B OPTIONAL 48V POWER SUPPLY, ADDENDUMTABLE OF CONTENTS Revisions Stackable Hubs, SNMP Optional Personal Switches, 10/100MbThe Magnum Line Personal Hubs, 10Mb seriesSwitches 1.0 SPECIFICATIONS 1.1 Technical Specifications PerformanceConnectors Network StandardsWarranty Power Supply InternalFor 48VDC power input option, see Appendix B Agency Approvals 1.2 Specifications - Repeater Port Modules RPMs1.4 Ordering Information Magnum 1000 Workgroup HubsMagnum Magnum Magnum 2.0 INTRODUCTION 2.1 Inspecting the Package and Product 2.2 Product Description - Magnum 1000-series Workgroup Hubs2.2.1 Magnum 1008 Workgroup Hub Figure 2.2.1a Front view - Magnum 1008 Workgroup HubMagnum 1000 Workgroup Hubs Installation and User Guide 04/02AC Power 115 - 230 VACRPM-FST Shown Configurable Bonus PortFigure 2.2.2b Front view - Magnum 1024 Workgroup Hub Figure 2.2.2c Rear view - Magnum 1016 and 1024 Workgroup HubsBPM shown Basic AUI portOptional PM card PM Ribbon cable with 16 pin headersBonus port for optional Basic AUI port PM card BPM shown Magnum 1000 Workgroup Hubs Installation and User Guide 04/022.4 Bonus Port Configuration Options - RPMs and BPMs Figure 2.4a Magnum RPM Cards RPM-BNC, RPM-AUIApprox Figure 2.4c Physical Dimensions of Magnum Port ModulesApprox. 3 inches 7.6 cm Approx. 2 inches 5.1 cm2.4.1 RPM-BNC 2.4.2 RPM-AUI2.4.3 RPM-DTE 2.4.4 RPM-FST Fiber ST, Twist-lock ConnectorConnector JUMPER ACROSSnot used 2.4.6 RPM-SMF Single-mode FiberMagnum RPM-SMF 2.4.7 RPM-TP Twisted Pair Magnum RPM-TP2.4.9 BPM-AUI 2.4.8 BPM-BNCMagnum BPM-BNC Magnum BPM-AUI2.4.11 BPM-TP 2.4.10 BPM-FSTMagnum BPM-FST 2.4.12 Special Option -- Second Bonus Port Models 1016 and Internal Universal Power Supply with Auto-ranging 2.5 Features and Benefits Low cost, stand-alone 10BASE-T connectivityLEDs Simplify Network Installation and Maintenance Workgroup connectivity into a larger network2.6 Applications Figure 2.6a Magnum 1000 Workgroup Hub in stand-alone configurationMagnum 1000 Workgroup Hub BNC Segment RPM-BNC Server 10241024 10161008 Fiber BPMinstalled in any standard 19 inch rack 3.0 INSTALLATIONinstallation requires a Rack-mount Brackets 3.2 Powering the Magnum 1000 Workgroup HubMedia 3.3.1 Connecting Twisted Pair RJ-45, Unshielded or Shielded3.3 Ethernet Media Connections IEEE Standard3.3.2 Connecting ThickNet 10BASE5 AUI 3.3.5 Connecting Fiber Optic 10BASE-FL and FOIRL ST-type, “Twist-Lock 3.3.3 Connecting ThinNet 10BASE2 BNC3.3.4 Connecting Drop Cable 10BASE5 DTE Table 3.3.2 AUI Pin Assignmentsat regular intervals you must use the color-coded strand on the 3.3.6 Connecting Fiber Optic SMA-type, Screw-on3.3.7 Connecting Single-Mode Fiber Optic SMF associated ports at each end of the fiber optic segmentOPB Optical Power Budget = PTmin - PRmin 3.3.9 Rack-mountingconsider as a standard for brackets are more popular inTELCO Industry and Rack-mounting purpose. TheCollisions When carrier is detected simultaneously on multiple ports, a jam pattern is generated on each port to create a collision condition. When a collision signal from one port is detected, it generates a jam pattern to the other ports Figure 4.2b Internal Packet Filtered 4.2 Magnum 1000’s with BPM Local Bridge FunctionalityPacket Forwarded Forwarded MaintenanceFigure 4.2c External Packet Table 4.2 BPM Functionality4.3 Power Requirements Figure 4.2e Local Segment Isolation with a Bridge Port Module BPM5.0 TROUBLESHOOTING 5.1 Before Calling for Assistance5.2 When Calling for Assistance 5.3 Return Material Authorization RMA ProcedureGarrettCom, Inc 213 Hammond Ave Fremont, CA Attn. Customer Service APPENDIX A WARRANTY INFORMATIONNo Problem Found 5.4 Shipping and Packaging InformationPower Supply Internal -48 VDC Option APPENDIX B Internal DC Power Supply OptionB1.0 SPECIFICATIONS - FOR MAGNUM 1000 WORKGROUP HUBS Power Supply Internal 24 VDC OptionFigure B4.1 -48VDC Terminal B4.0 INSTALLATIONB3.0 APPLICATIONS Block on Magnum 1000’s-48VDCB4.1 UL Requirements B7.0 TROUBLESHOOTINGThe GND can be hooked at the last B5.0 OPERATION