GarrettCom 1016 Magnum 1000 Workgroup Hubs, Installation and User Guide 04/02, AC Power, LEDs

Page 12
Magnum 1000 Workgroup Hubs

Magnum 1000 Workgroup Hubs

Installation and User Guide (04/02)

 

AC Power

 

 

 

 

 

 

115 - 230 VAC

Basic AUI Port

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 2.2.1b: Rear view - Magnum 1008 Workgroup Hub with the basic AUI port

As an alternative to the basic AUI port, it is possible (at the time of initial order) to replace the basic AUI rear port with any Magnum Port Module (PM). (See Figure 2.2.1c). This option gives the Magnum 1008 great flexibility to easily conform to any standard Ethernet media environment. When configured with a Repeater Port Module (RPM), the rear port can be used for direct connection to any standard Ethernet media. With a Bridge Port Module (BPM), the rear port is used to bridge-isolate the Magnum 1008 from the rest of the network, increasing bandwidth for both the local users and the rest of the network. Refer to Section 2.4 for Magnum Port Module information. (NOTE: The Magnum 1008’s basic AUI port is NOT an RPM-AUI, it is

simply an AUI port without any

AC Power

Port Module

LEDs).

115 - 230 VAC

(RPM-FST shown)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 2.2.1c: Rear view - Magnum 1008 Workgroup Hub configured with PM

2.2.2Magnum 1016 and 1024 Workgroup Hubs

The Magnum 1016 Workgroup Hub is equipped with 16 front-mounted, shielded RJ-45 ports, 1 rear-mounted basic AUI port and 1 rear Bonus Port slot (see Figure 2.2.2a). The left-most front RJ-45 port (port 1) is equipped with a slide switch to allow cascading or an up-link without a crossover cable.

Magnum 1016

Workgroup Hub

Installation and User Guide (04/02) GARRETT

1

2

3

4

5

6

7

8

 

9

10

11

12

13

14

15

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 2.2.2a: Front view - Magnum 1016 Workgroup Hub

The Magnum 1024 Workgroup Hub is equipped with 24 front-mounted, shielded RJ-45 ports, 1 rear-mounted AUI port and 1 rear Bonus Port slot (see Figure 2.2.2b).

www . GarrettCom . com

6

Image 12
Contents Models 1008, 1016 and Installation and User GuideMagnum Workgroup Hubs “Ten Series” www . GarrettCom . comWorkgroup Hubs Installation and User Guide Magnum 1008, 1016 andand optional 48VDC, 24VDC &125VDC-powered models Installation and User Guide 04/02GarrettCom, Inc 47823 Westinghouse Drive Fremont, CAPhone 510 Fax 510APPENDIX B OPTIONAL 48V POWER SUPPLY, ADDENDUM TABLE OF CONTENTSPage Revisions Personal Switches, 10/100Mb The Magnum LineStackable Hubs, SNMP Optional Personal Hubs, 10Mb series1.0 SPECIFICATIONS 1.1 Technical Specifications Performance ConnectorsSwitches Network StandardsPower Supply Internal For 48VDC power input option, see Appendix B Agency ApprovalsWarranty 1.2 Specifications - Repeater Port Modules RPMsMagnum 1000 Workgroup Hubs Magnum Magnum Magnum1.4 Ordering Information 2.0 INTRODUCTION 2.1 Inspecting the Package and Product 2.2 Product Description - Magnum 1000-series Workgroup Hubs2.2.1 Magnum 1008 Workgroup Hub Figure 2.2.1a Front view - Magnum 1008 Workgroup HubInstallation and User Guide 04/02 AC PowerMagnum 1000 Workgroup Hubs 115 - 230 VACConfigurable Bonus Port Figure 2.2.2b Front view - Magnum 1024 Workgroup HubRPM-FST Shown Figure 2.2.2c Rear view - Magnum 1016 and 1024 Workgroup HubsBasic AUI port Optional PM cardBPM shown PM Ribbon cable with 16 pin headersMagnum 1000 Workgroup Hubs Installation and User Guide 04/02 2.4 Bonus Port Configuration Options - RPMs and BPMsBonus port for optional Basic AUI port PM card BPM shown Figure 2.4a Magnum RPM Cards RPM-BNC, RPM-AUIFigure 2.4c Physical Dimensions of Magnum Port Modules Approx. 3 inches 7.6 cmApprox Approx. 2 inches 5.1 cm2.4.1 RPM-BNC 2.4.2 RPM-AUI2.4.3 RPM-DTE RPM-FST Fiber ST, Twist-lock Connector Connector2.4.4 JUMPER ACROSS2.4.6 RPM-SMF Single-mode Fiber Magnum RPM-SMFnot used 2.4.7 RPM-TP Twisted Pair Magnum RPM-TP2.4.8 BPM-BNC Magnum BPM-BNC2.4.9 BPM-AUI Magnum BPM-AUI2.4.10 BPM-FST Magnum BPM-FST2.4.11 BPM-TP 2.4.12 Special Option -- Second Bonus Port Models 1016 and 2.5 Features and Benefits Low cost, stand-alone 10BASE-T connectivity LEDs Simplify Network Installation and MaintenanceInternal Universal Power Supply with Auto-ranging Workgroup connectivity into a larger networkFigure 2.6a Magnum 1000 Workgroup Hub in stand-alone configuration Magnum 1000 Workgroup Hub2.6 Applications BNC Segment RPM-BNC Server 10241016 10081024 Fiber BPM3.0 INSTALLATION installation requires ainstalled in any standard 19 inch rack Rack-mount Brackets 3.2 Powering the Magnum 1000 Workgroup Hub3.3.1 Connecting Twisted Pair RJ-45, Unshielded or Shielded 3.3 Ethernet Media ConnectionsMedia IEEE Standard3.3.2 Connecting ThickNet 10BASE5 AUI 3.3.3 Connecting ThinNet 10BASE2 BNC 3.3.4 Connecting Drop Cable 10BASE5 DTE3.3.5 Connecting Fiber Optic 10BASE-FL and FOIRL ST-type, “Twist-Lock Table 3.3.2 AUI Pin Assignments3.3.6 Connecting Fiber Optic SMA-type, Screw-on 3.3.7 Connecting Single-Mode Fiber Optic SMFat regular intervals you must use the color-coded strand on the associated ports at each end of the fiber optic segmentOPB Optical Power Budget = PTmin - PRmin 3.3.9 Rack-mountingbrackets are more popular in TELCO Industry andconsider as a standard for Rack-mounting purpose. TheCollisions When carrier is detected simultaneously on multiple ports, a jam pattern is generated on each port to create a collision condition. When a collision signal from one port is detected, it generates a jam pattern to the other ports 4.2 Magnum 1000’s with BPM Local Bridge Functionality Packet ForwardedFigure 4.2b Internal Packet Filtered Maintenance Figure 4.2c External PacketForwarded Table 4.2 BPM Functionality4.3 Power Requirements Figure 4.2e Local Segment Isolation with a Bridge Port Module BPM5.0 TROUBLESHOOTING 5.1 Before Calling for Assistance5.2 When Calling for Assistance 5.3 Return Material Authorization RMA ProcedureAPPENDIX A WARRANTY INFORMATION No Problem FoundGarrettCom, Inc 213 Hammond Ave Fremont, CA Attn. Customer Service 5.4 Shipping and Packaging InformationAPPENDIX B Internal DC Power Supply Option B1.0 SPECIFICATIONS - FOR MAGNUM 1000 WORKGROUP HUBSPower Supply Internal -48 VDC Option Power Supply Internal 24 VDC OptionB4.0 INSTALLATION B3.0 APPLICATIONSFigure B4.1 -48VDC Terminal Block on Magnum 1000’s-48VDCB7.0 TROUBLESHOOTING The GND can be hooked at the lastB4.1 UL Requirements B5.0 OPERATION