Collisions: When carrier is detected simultaneously on multiple ports, a jam pattern is generated on each port to create a collision condition. When a collision signal from one port is detected, it generates a jam pattern to the other ports.

Magnum 1000 Workgroup Hubs

Installation and User Guide (04/02)

Collisions: When carrier is detected simultaneously on multiple ports, a jam pattern is generated on each port to create a collision condition. When a collision signal from one port is detected, it generates a jam pattern to the other ports.

Partitioning and Re-Connection:Magnum 1000 Hubs will automatically partition any port where 32 consecutive collisions occur or after 6.5 milliseconds (msec) of continuous transmissions. Network integrity is checked every 800 msec and segment re-connection occurs after one 512-bit packet is transmitted without an error.

Fragment Extension: Magnum 1000 Hubs will automatically add bits to a received data packet of less than 96 bits (a "fragment") so that the minimum output packet to the other port is 96 bits long.

Preamble Regeneration: Magnum 1000 Hubs will add bits to the preamble so that the output packet contains a minimum of a 64-bit preamble.

Status LEDs: Each Magnum 1000 Workgroup Hub is designed with front panel LEDs to allow for quick visual assessment of the operational condition of the hub and the network. Each Magnum 1000 Hub is equipped with PWR, ACT, and LINK LEDs. Bonus Port RPMs are also equipped with status LEDs (see Section 2.4).

PWR LED: Illuminates GREEN to indicate proper operation of the internal power supply.

ACT LED: Illuminates GREEN to indicate “activity”, i.e., that the hub is processing network packets. Normally flashes to indicate data traffic.

LINK LEDs: Illuminates GREEN when connectivity is established between the hub and the attached device. Each RJ-45 port is represented by its own LINK LED. LINK should always be on during normal operation. LINK is OFF if connectivity or power is lost anywhere along the segment.

www . GarrettCom . com

29

Image 35
Contents www . GarrettCom . com Models 1008, 1016 andInstallation and User Guide Magnum Workgroup Hubs “Ten Series”Installation and User Guide 04/02 Workgroup Hubs Installation and User GuideMagnum 1008, 1016 and and optional 48VDC, 24VDC &125VDC-powered modelsFax 510 GarrettCom, Inc47823 Westinghouse Drive Fremont, CA Phone 510Page APPENDIX B OPTIONAL 48V POWER SUPPLY, ADDENDUMTABLE OF CONTENTS Revisions Personal Hubs, 10Mb series Personal Switches, 10/100MbThe Magnum Line Stackable Hubs, SNMP OptionalNetwork Standards 1.0 SPECIFICATIONS 1.1 Technical Specifications PerformanceConnectors Switches1.2 Specifications - Repeater Port Modules RPMs Power Supply InternalFor 48VDC power input option, see Appendix B Agency Approvals Warranty1.4 Ordering Information Magnum 1000 Workgroup HubsMagnum Magnum Magnum 2.2 Product Description - Magnum 1000-series Workgroup Hubs 2.0 INTRODUCTION 2.1 Inspecting the Package and ProductFigure 2.2.1a Front view - Magnum 1008 Workgroup Hub 2.2.1 Magnum 1008 Workgroup Hub115 - 230 VAC Installation and User Guide 04/02AC Power Magnum 1000 Workgroup HubsFigure 2.2.2c Rear view - Magnum 1016 and 1024 Workgroup Hubs Configurable Bonus PortFigure 2.2.2b Front view - Magnum 1024 Workgroup Hub RPM-FST ShownPM Ribbon cable with 16 pin headers Basic AUI portOptional PM card BPM shownFigure 2.4a Magnum RPM Cards RPM-BNC, RPM-AUI Magnum 1000 Workgroup Hubs Installation and User Guide 04/022.4 Bonus Port Configuration Options - RPMs and BPMs Bonus port for optional Basic AUI port PM card BPM shownApprox. 2 inches 5.1 cm Figure 2.4c Physical Dimensions of Magnum Port ModulesApprox. 3 inches 7.6 cm Approx2.4.2 RPM-AUI 2.4.1 RPM-BNC2.4.3 RPM-DTE JUMPER ACROSS RPM-FST Fiber ST, Twist-lock ConnectorConnector 2.4.4not used 2.4.6 RPM-SMF Single-mode FiberMagnum RPM-SMF Magnum RPM-TP 2.4.7 RPM-TP Twisted PairMagnum BPM-AUI 2.4.8 BPM-BNCMagnum BPM-BNC 2.4.9 BPM-AUI2.4.11 BPM-TP 2.4.10 BPM-FSTMagnum BPM-FST 2.4.12 Special Option -- Second Bonus Port Models 1016 and Workgroup connectivity into a larger network 2.5 Features and Benefits Low cost, stand-alone 10BASE-T connectivityLEDs Simplify Network Installation and Maintenance Internal Universal Power Supply with Auto-rangingBNC Segment RPM-BNC Server 1024 Figure 2.6a Magnum 1000 Workgroup Hub in stand-alone configurationMagnum 1000 Workgroup Hub 2.6 ApplicationsFiber BPM 10161008 1024Rack-mount Brackets 3.2 Powering the Magnum 1000 Workgroup Hub 3.0 INSTALLATIONinstallation requires a installed in any standard 19 inch rackIEEE Standard 3.3.1 Connecting Twisted Pair RJ-45, Unshielded or Shielded3.3 Ethernet Media Connections Media3.3.2 Connecting ThickNet 10BASE5 AUI Table 3.3.2 AUI Pin Assignments 3.3.3 Connecting ThinNet 10BASE2 BNC3.3.4 Connecting Drop Cable 10BASE5 DTE 3.3.5 Connecting Fiber Optic 10BASE-FL and FOIRL ST-type, “Twist-Lockassociated ports at each end of the fiber optic segment 3.3.6 Connecting Fiber Optic SMA-type, Screw-on3.3.7 Connecting Single-Mode Fiber Optic SMF at regular intervals you must use the color-coded strand on the3.3.9 Rack-mounting OPB Optical Power Budget = PTmin - PRminRack-mounting purpose. The brackets are more popular inTELCO Industry and consider as a standard forCollisions When carrier is detected simultaneously on multiple ports, a jam pattern is generated on each port to create a collision condition. When a collision signal from one port is detected, it generates a jam pattern to the other ports Figure 4.2b Internal Packet Filtered 4.2 Magnum 1000’s with BPM Local Bridge FunctionalityPacket Forwarded Table 4.2 BPM Functionality MaintenanceFigure 4.2c External Packet ForwardedFigure 4.2e Local Segment Isolation with a Bridge Port Module BPM 4.3 Power Requirements5.1 Before Calling for Assistance 5.0 TROUBLESHOOTING5.3 Return Material Authorization RMA Procedure 5.2 When Calling for Assistance5.4 Shipping and Packaging Information APPENDIX A WARRANTY INFORMATIONNo Problem Found GarrettCom, Inc 213 Hammond Ave Fremont, CA Attn. Customer ServicePower Supply Internal 24 VDC Option APPENDIX B Internal DC Power Supply OptionB1.0 SPECIFICATIONS - FOR MAGNUM 1000 WORKGROUP HUBS Power Supply Internal -48 VDC OptionBlock on Magnum 1000’s-48VDC B4.0 INSTALLATIONB3.0 APPLICATIONS Figure B4.1 -48VDC TerminalB5.0 OPERATION B7.0 TROUBLESHOOTINGThe GND can be hooked at the last B4.1 UL Requirements