GE EPM 5300, EPM 5200, EPM 5350 instruction manual Set Limits/Relays, Mode, REFERENCE………………81

Page 4

CHAPTER 10: PROGRAMMING GROUP 1:

 

VOLTAGE, AMP AND WATT

 

SCALE SETTINGS

55

10.1: Group 1, Function 0—Full

 

Scale Voltage Settings, Scale

 

Factor & Decimal Point

 

Placement

55

10.2: Group 1, Function 1—

 

Amperage Full Scale

58

10.3: Group 1, Function 2—Scale

 

Selection and Decimal

 

Placement for Watts

59

CHAPTER 11: PROGRAMMING GROUP 2:

 

METER CALIBRATION

63

11.1: Calibration Requirements

63

11.2: Group 2, Functions 0–8—

 

High End Calibration of Voltage

Channels, High and Low End

 

Calibration of Amperage

 

Channels

64

CHAPTER 12: GROUPS 4, 5 AND 6: SET

 

LIMITS AND RELAYS ...

67

12.1: Trip Relay

67

12.2: Time Delays & Relay Mode ....

67

12.3: Group 4, Functions 0–3—

 

LM1/LM2 Set Limits

68

12.4: Group 5, Functions 0–7—

 

LM1/LM2 Set Limits

69

12.5: Group 6, Functions 0–5—

 

LM1/LM2 Set Limits and

 

Relay Triggers for Over/Under

 

%THD Conditions

72

12.6: Limits or Relays Programming

 

Procedure

72

CHAPTER 13: PHASE REVERSAL

 

AND PHASE IMBALANCE

 

SET LIMITS/RELAYS

75

13.1: Phase Reversal and Phase

 

Imbalance

75

13.2: Trip Relay

75

13.3: Group 7, Function 0—Voltage

 

Phase Reversal Detection

76

13.4: Group 7, Function 1—

 

Percentage Voltage Phase

 

Imbalance

77

CHAPTER 14: EXITING THE PROGRAMMING

MODE

79

CHAPTER 15: PROGRAMMING QUICK

 

REFERENCE………………81

15.1: Entering the Programming

 

Mode

81

15.2: Data Entry Sequence

81

15.3: Programming Groups

81

15.4: Group 0: Global Setup

82

15.5: Group 1: Full Scale Setup

83

15.6: Group 2 Calibration

83

15.7: Group 3 Calibration Ratios

83

15.8: Group 4: Volt/Current Limits...

83

15.9: Group 5: Power Function Limits

.........................................................

84

15.10: Group 6: THD Limits

84

15.11: Group 7 Imbalance/Reversal

 

Limits

84

15.12: Group 8: DC Output

 

Calibration

84

CHAPTER 16: ETHERNET OPTION

87

16.1: Ethernet Module

 

...............................................

87

16.2: Ethernet Option Setup

88

16.3: Default IP Address…………….89

16.4: AutoIP…………………………..89

16.5: Setting the IP Address………..89

16.6: Network Configuration………..90

16.7: Configuration Parameters…….91

GE Multilin

EPM 5000 series Advanced Power Meters

iv

Image 4
Contents Digital Multifunction Power Monitors EPM 5200, 5300Page Table of Contents Mode SET LIMITS/RELAYSREFERENCE………………81 Chapter AC Power Measurement Single Phase SystemThree-Phase System Relationship between apparent, real Reactive powerConsumption, Demand and Poor Power Factor Poly Phase System 1 Delta, 2 WyeSinusoidal Waveform a sin ω ⋅ t Waveform and HarmonicsTotal Harmonic Distortion THD Chapter Mechanical Installation Diagram 2.1 Standard installationPort Chapter Electrical Installation Connecting the Current CircuitCT Connection Helpful Debugging ToolsConnecting the Voltage Circuit Connection to the Main Power SupplyElectrical Connection Installation Control Power Option Suffix CurrentList of Connection Diagrams 2L1 IV. Three-Phase Four-Wire Wye with Direct Voltage and CTs Three Phase Four-Wire Wye with CT and PTsLine Back View LoadVI. Single Phase with CT and PT Connection EPM 5300P-SVII. Dual-Phase with CTs and PTs VIII. Three-Phase Four-Wire WYE with 2.5 ElementEPM 5300P Relay Overview Relay, Protection and Pulse OutputRelays & 1 KYZ Pulse Output -NL Option Decimal Point Placement Change in Level KW/MW Standard Rate Table for WattsKYZ Pulse Outputs NL2 Option Voltage9999.0 Units W Hour 999.9 99.99 KYZ Relay Connection for -NL2 OptionChapter Communication Installation RS-232CRS-485 Connection for DB-9 FemaleRS-485 Hookup Diagram 2 wire Half Duplex RS-485 Hookup Diagram 2 wire Half Duplex Closed Loop RS-485 Hookup Diagram 2 wire Half Duplex Detail View RS-485 Hookup Diagram 4 wire Full Duplex RS-485 Hookup Diagram 4 wire Full Duplex Detail View Bottom View ShownNetwork of Instruments and Long Distance Communication ComputerModem Connected to Computer Originate Modem Programming the ModemDebugging Communication Problems Communication Installation Power A, B, C Chapter OverviewAccessing Voltage and Current Phases Accessing the Power FunctionsAccessing %THD Functions Viewing Individual Phase Indication for Power Functions StepResetting Values Unprotected Reset Protected ResetResetting Hour Readings Accessing the LM1/LM2 Set LimitsVoltage Phase Reversal and Imbalance Phase Reversal Phase ImbalanceThis display Press and hold down Indicates a VoltageAccess Modes Appears, confirming a successful print commandPrint Operating Data Press and hold Press Amps until a AppearsStep Press and hold PHASE/NEXT Press Amps until 4 appears Accessing Firmware Version/LED TestPrint Programming Data Step General Procedure Switch PacksChapter Programming Overview Groups Functions PacksProgramming Mode Data Entry Standard Numeric Data EntryChapter EPM 5200PEPM 5300P vs. EPM 5200P vs. EPM 5350P Feature 5300P 5200P 5350P5300P 5200P 5350P Chapter Entering Programming Mode Checksum Error-Protective Self-Checking AlgorithmsPassword Entry Entering Programming ModeEntering Programming Mode Chapter Programming Group 0 Global Meter Setup Group 0, Function 0-The Integration IntervalFunction FunctionGroup 0, Function 1-The Meter Address Group 0, Function 2-BAUD Rate Group 0, Function 3-System Configuration Group Function PackPack Switch Feature Segment Position Down +PFOpen Delta System Installation Programming Modbus Plus CapabilityPrinting Option Disabling PreventsGroup 0, Function 3-Programming Procedure To change the System Configuration Switch SettingsRelay Mode Switch DescriptionSwitch C Description DefinitionsGroup 0-FUNCTION Number Description Programming Steps04.P Controls Relay 05.P Controls Relay 2 and 3 if NL4 To change the Relay Mode to either Fail-safe or Reset Group and Function Number Description To change Time Delays To program RelayGroup 0, Function 6-KYZ Parameter Selection Parameter DescriptionSelection KYZ Pulse KYZ Pulse Value 06PValue PER PER Watt Hour FSW=9.999Situation 3 FSW=99.99 Situation 4 FSW=9.999Group 0, Function 7-Number of Phases Standard Factory SET-UP is THREE-PHASE FOUR-WIREFormulas Group and Function NumberTo change the Full Scale Settings Voltage Full ScalePress Volts to move decimal point Press Amps to store Group 1, Function 1-Amperage Full Scale CT T YPE Full ScaleStep Press Amps to begin Data Entry Sequence FSV=480 FSA=1000 a FSW one phase=480 V ⋅ 1000 a Example 2 480/120 PT, 1000/5 CTExample 3 14.4 KV/120, 1000/5 CT FSV=14.40 KV FSA=1000 aTo change the scale factor setting for wattage Programming Group Chapter Programming Group 2-METER Calibration Calibration RequirementsHigh End Calibration-Volts AN, BN, CN High End Calibration-Amps A, B, CVoltage Range Input Source Group 2 Value To change the calibration high end-Functions 0For Amps Low End Function Press MAX/MIN/LIMITS to end calibration procedure Time Delays & Relay Mode Chapter Groups 4, 5 and 6-SET Limits and RelaysExample of LM1/LM2 SET Limits Trip RelayGroup 4, Functions 0-3-LM1/LM2 Set Limits Group 4 Programming Format for Limit ConditionGroup 5, Functions 0-7-LM1/LM2 Set Limits There are 3 Switches to SET with Limits Digit Up Digit Down 0120LM1 LM2 Switch Value LED ABOVE/BELOW Relay Programming Group 6, LM1/LM2 Set LimitsLimits or Relays Programming Procedure LM1 LED LM2 LED Switch Level ABOVE/BELOW RelayDigit Up Digit Down 012.0 Digit Down Digit Up 009.0Press Amps once to Disable the Limit Follow this step for Disabling LimitsSee to Exit Phase Reversal and Phase Imbalance ∃TRIP Relay 1 %TRIP Relay 2 &LEVEL ∋ENABLE/DISABLEGroup 7, Function 0-Voltage Phase Reversal Detection Voltage Phase Reversal DetectionVoltage Phase Imbalance To change the phase reversal settingGroup 7, Function 1-Percentage Voltage Phase Imbalance To change the percentage voltage phase imbalanceSee to Exit Chapter Exiting Programming Mode Exiting Programming Mode Entering the Programming Mode Chapter Programming Quick ReferenceData Entry Sequence Programming GroupsGroup 0-Global Meter Setup Reserved SwitchesGroup 1 Full Scale Setup Group 2 CalibrationGroup 3 Calibration Ratios Group 4 Volt/Current LimitsGroup 5 Power Function Limits Group 6 THD LimitsGroup 7 Imbalance/Reversal Limits Group 8 DC output CalibrationKEY Designations Programming Quick Reference Chapter Ethernet Option Ethernet ModuleEthernet Option Setup Description LED FunctionsDefault IP Address Setting the IP AddressNetwork Port Login AutoIPARP on Windows Network ConfigurationTelnet to Port Configuration Parameters Baud RateGE Multilin