Gefen GEF-DVIKVM-848DL user manual #LOCKEDID Function, #LOCKEDID param1, #LOEDIDTOLO Function

Page 23

RS-232 SERIAL CONTROL

#LOCKEDID Function

The #LOCKEDID function secures the Local EDID and disables the automatic loading of the downstream EDID after the Matrix is powered on.

Syntax:

#LOCKEDID param1

Parameters:

 

 

param1

Input

[0 - 1]

 

 

 

 

Value

Meaning

 

0

Disable

 

1

Enable

#LOEDIDTOLO Function

The #LOEDIDTOLO function loads an external EDID via RS-232 to any Local EDID input bank.

Syntax:

#LOEDIDTOLO param1 param2 param3

Parameters:

 

 

param1

Input

[1 - 8]

param2

EDID size

[1 - 2]

 

 

 

 

Value

Meaning

 

 

 

 

1

128 byte EDID

 

2

256 byte EDID

param3

eco

[0 - 1]

Notes:

Set param1 to a value of 0 in order to specify all inputs. When using HyperTermi- nal, param3 must be set to 1.

20

Image 23
Contents 8x8 DVI KVM Dual Link Matrix Write To Asking for AssistanceTechnical Support Technical Support HoursContents How It Works IntroductionGefenPRO GefenPRO 8x8 DVI KVM Dual Link MatrixOperation Notes Package Includes FeaturesFeatures Front Panel Panel LayoutControl Buttons Panel DescriptionsBack Panel 1110 1 2 3 RS-232 Serial Port Back PanelHow to Operate the GefenPRO 8x8 DVI KVM Dual Link Matrix Connecting the 8X8 DVI KVM Dual Link MatrixHow to Connect the GefenPRO 8x8 DVI KVM Dual Link Matrix Displaying the Firmware Version Displaying the Bootloader VersionFront Panel Display Main DisplayRouting Sources Displaying the Routing StatusMonitor and Source Selection Buttons 1 Remote Control UnitEmpty Battery Slot IR Remote InstallationInstalling the RMT-16IR Battery Setting the IR Remote Control Channel IR Remote ConfigurationIR Remote Control Key Mapping Using the IR Remote Control UnitEdid Management EDID. What is it and what is it used for?3 2 3 4 RS-232 Serial ControlFunctions Syntax RS-232 Features#EDIDDSTOBA param1 param2 #EDIDDSTOLO Function#EDIDDSTOLO param1 param2 param3...param9 #EDIDDSTOBA Function#EDIDDETOLO param1 param2 param3...param9 #EDIDBATOLO Function#EDIDBATOLO param1 param2 param3...param9 #EDIDDETOLO Function#LOEDIDTOLO param1 param2 param3 #LOCKEDID Function#LOCKEDID param1 #LOEDIDTOLO Function#PRBAEDID Function #PRDSEDID Function#PRLOEDID Function #PRWEBADD Function #PREDIDST Function#SIPADD param1 param2 param3 param4 #RSTIP Function#SIPADD Function #SGATEWAY param1 param2 param3 param4 #SNETMASK Function#SNETMASK param1 param2 param3 param4 #SGATEWAY Function#SPORT param1 #ACTIVEBOLO Function #FADEFAULT Function#MASKOUT param1 param2 #LOCKPOWER Function#LOCKPOWER param1 #MASKOUT Function#STBYMODE param1 #RMTIRADD Function#RMTIRADD param1 #STBYMODE FunctionParam1 Commands Command DescriptionCommand Param1 param2Syntax Parameters None View Matrix Status IP ControlCopy Edid Edid Lock State Manage EdidManage Edid Set Input to Default Edid Manage Edid Copy Edid Manage Edid Edid Lock State Masking IP Configuration Power Management Backup / Restore========================================================= Firmware UpdateFirmware Update Procedure Programming Completed Successfully Waiting for the file to be sent ... press ‘a’ to abortRack Mount Safety Information Specifications Product Registration WarrantyLicensing Page Rev A6 Nordhoff St., Chatsworth CA