FortiGate-5050 front panel
Figure 7 shows the front of a FortiGate-5050 chassis. Two FortiSwitch-5003 boards are installed in slots 1 and 2. Three FortiGate-5001SX boards are installed in slots 3, 4, and 5.
The FortiGate-5050 primary Shelf Manager is also visible. The factory-installed shelf managers provide power distribution, cooling, alarms, shelf status, and a telco alarm interface for the FortiGate-5050 chassis.
Figure 7: FortiGate-5050 front panel with FortiGate-5001SX and FortiSwitch-5003 boards installed
FortiGate-5001SX
boards
slots 3, 4,
and 5
FortiSwitch-5003
boards
slots 1 and 2
5 | CONSOLE | USB | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
|
PWR ACC |
|
|
|
|
|
|
|
| STA | IPM | |
|
|
|
|
|
|
|
|
|
|
|
4 | CONSOLE | USB | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
|
PWR ACC |
|
|
|
|
|
|
|
| STA | IPM | |
|
|
|
|
|
|
|
|
|
|
|
3 | CONSOLE | USB | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
|
PWR ACC |
|
|
|
|
|
|
|
| STA | IPM | |
|
|
|
|
|
|
|
|
|
|
|
2 | MANAGEMENT | TE H O | SYSTEM | CONSOLE | SR 2 3 2 | RZ E 0 | RZ E 1 | RZ E 2 | E2 E1 | 14 15 | 12 13 | 10 11 | 8 9 | 6 7 | 4 5 | 2 3 | 0 1 | ZRE | CLK OK | EXT INT FLT FLT | HOT SWAP | RESET | LEDMODE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| POWER |
1 | MANAGEMENT | ET H O | SYSTEM | CONSOLE | RS 2 3 2 | RZ E 0 | RZ E 1 | RZ E 2 | E2 E1 | 14 15 | 12 13 | 10 11 | 8 9 | 6 7 | 4 5 | 2 3 | 0 1 | ZRE | CLK OK | EXT INT FLT FLT | SWAPHOT | RESET | LED MODE |
ShMC |
| Critical |
|
| Hot Swap | ShMC |
2 |
| Major |
|
| 1 | |
Alarm | Minor |
|
| Status | ||
Alarm | Console | Ethernet |
| |||
| Reset |
|
|
|
Power LED
ESD socket | |
Shelf Manager |
|
Also visible on the front of the
•Electrostatic discharge (ESD) socket, used for connecting an ESD wrist or ankle band when working with the chassis.
•The location of the hot swappable
•Power LED.
Caution: Do not operate the
FortiGate-5050 back panel
Figure 8 shows the back panel of a FortiGate-5050 chassis. The back panel includes two redundant -48V to - 58V DC power input connectors labelled Input A and Input B. The power input connectors provide redundant DC power connections for the FortiGate-5050 chassis and distribute DC power to the fan tray and the FortiGate-5000 series boards installed in the FortiGate-5050 chassis. Each power input connector includes a 24 Amp circuit breaker that also functions as an on/off switch for the power input connector.
If you require redundant power you should connect both power input connectors to DC power. If redundant power is not required, you should connect power input connector A to DC power. When operating, the power input connectors are covered with clear protection plates.
FortiGate-5000 Series Introduction
2801-30000-83466-20090108http://docs.fortinet.com/ • Feedback