Fortinet 5050-R manual Shelf manager command line interface CLI

Page 12

Shelf manager command line interface (CLI)

FortiGate-5050 chassis

Table 5: Telco alarm connector pin assignment

Pin

Name

Description

 

 

 

1

AMIR+

MinorReset+

 

 

 

2

AMIR-

MinorReset-

 

 

 

3

AMAR+

MajorReset+

 

 

 

4

AMAR-

MajorReset-

 

 

 

5

ACNO

CriticalAlarm - NO

 

 

 

6

ACNC

CriticalAlarm - NC

 

 

 

7

ACCOM

CriticalAlarm - COM

 

 

 

8

AMINO

MinorAlarm -NO

 

 

 

9

AMINC

MinorAlarm - NC

 

 

 

10

AMINCOM

MinorAlarm - COM

 

 

 

11

AMANO

MajorAlarm - NO

 

 

 

12

AMANC

MajorAlarm - NC

 

 

 

13

AMACOM

MajorAlarm - COM

 

 

 

14

APRCO

PwrAlarm - NO

 

 

 

15

APRCOM

PwrAlarm - COM

 

 

 

Shield

Shelf-GND

Shelf Ground

 

 

 

Shelf manager command line interface (CLI)

You can use the shelf manager CLI to communicate with the intelligent management controllers of the chassis, with boards in the chassis, and with the shelf manager itself. The CLI is an IPMI-based set of commands that can be accessed directly or through a higher-level management application or a script. Using the CLI, you can access information about the current state of the chassis including current board population, current sensor values, threshold settings, recent events, and overall chassis health.

Connecting to the shelf manager CLI using a serial port

You can connect to the shelf manager CLI by connecting the console cable supplied with your chassis to a management PC console port and to the appropriate shelf alarm panel serial port. To connect to the primary shelf manager use Serial 1. To connect to the secondary shelf manager use Serial 2.

FortiGate-5050-R Chassis Guide

1201-30000-87717-20090108http://docs.fortinet.com/ Feedback

Image 12
Contents FortiGate-5050-R FortiGate-5050-R Chassis Guide Contents Contents FortiGate-5050-R Chassis Guide FortiGate-5050 chassis Power LED FortiGate-5050 front panelFortiGate-5050 back panel RTMPhysical description of the FortiGate-5050 chassis FortiGate-5050 shelf managers FortiGate-5050 shelf alarm panel Shelf Manager fan and power controlUSER3 Shelf alarm panel telco alarms 5050SAPShelf manager command line interface CLI Connecting to the shelf manager CLI using a serial portFortiGate-5050 Shelf Alarm Panel To use the shelf manager command line interface agent Clia Power connection and configuration About data center DC powerRTN Connecting the FortiGate-5050 chassis to data center ground To connect the FortiGate-5050 chassis to data center groundFortiGate-5053 power converter tray front and back panel LEDBasic power requirements Redundant FortiGate-5050 power supplies Redundant FortiGate-5053 power converter traysRedundant FortiGate-5053 power converter trays FortiGate-5050-R Chassis Guide Red RTN to Black VDC to FortiGate-5053 Turning on FortiGate-5050 chassis power Wiring the FortiGate-5053 power converter trayMounting the FortiGate-5050 chassis Inserting 5000 series modules into a FortiGate-5050 chassisAir flow FortiGate-5050 hardware procedures Customer service and technical support Fortinet documentationRegister your Fortinet product Vcci