Fortinet 5050-R manual FortiGate-5050 hardware procedures

Page 26

Using FortiSwitch-5003A and FortiSwitch-5003 boards for backplane communication

FortiGate-5050 hardware procedures

Caution: FortiGate-5000 series and FortiSwitch-5000 series modules must be protected from static discharge and physical shock. Only handle or work with FortiGate-5000 series and FortiSwitch-5000 series modules at a static-free workstation. Always wear a grounded electrostatic discharge (ESD) preventive wrist or ankle strap when handling FortiGate-5000 series or FortiSwitch-5000 series modules.

Caution: Do not operate the FortiGate-5050 chassis with open slots on the front panel or rear panel. For optimum cooling performance and safety, front panel slots must contain a FortiGate-5000 series module or an air baffle slot filler and rear panel slots must either be covered or must contain a rear transition module or slot filler. As well the removable PEM terminal block covers must be installed over the power connectors on the back of the chassis.

See the following documents for information about installing and removing the following

FortiGate-5000 series and FortiSwitch-5000 series modules:

FortiGate-5001A

FortiGate-5001A Security System Guide FortiGate-5005FA2:

FortiGate-5005FA2 Security System Guide FortiGate-5001SX:

FortiGate-5001SX Security System Guide FortiGate-5001FA2:

FortiGate-5001FA2 Security System Guide FortiSwitch-5003A

FortiSwitch-5003A System Guide FortiGate-RTM-XB2

FortiGate-RTM-XB2 System Guide FortiSwitch-5003

FortiSwitch-5003 System Guide

Using FortiSwitch-5003A and FortiSwitch-5003 boards for backplane communication

FortiSwitch-5003A boards installed in a FortiGate-5050 chassis in slot 1 or slot 2 provide fabric backplane switching for all of the FortiGate-5000 series boards installed in chassis slots 3 and above. Fabric backplane switching is most often used for data communication between FortiGate-5000 series boards in a chassis, between chassis, and between the chassis and the network.

FortiSwitch-5003A and 5003 boards installed in a FortiGate-5050 chassis in slot 1 or slot 2 provide base backplane switching for all of the FortiGate-5000 series boards installed in chassis slots 3 and above. Base backplane switching is usually used for HA heartbeat communication between FortiGate-5000 series boards in HA clusters.

For complete information about using the FortiSwitch-5003A and 5003 for backplane communications (including the FortiSwitch-5003A CLI reference), see the FortiSwitch-5003A and 5003 Fabric and Base Backplane Communication Guide.

FortiGate-5050-R Chassis Guide

2601-30000-87717-20090108http://docs.fortinet.com/ Feedback

Image 26
Contents FortiGate-5050-R FortiGate-5050-R Chassis Guide Contents Contents FortiGate-5050-R Chassis Guide FortiGate-5050 chassis Power LED FortiGate-5050 front panelFortiGate-5050 back panel RTMPhysical description of the FortiGate-5050 chassis FortiGate-5050 shelf managersFortiGate-5050 shelf alarm panel Shelf Manager fan and power controlUSER3 Shelf alarm panel telco alarms 5050SAPShelf manager command line interface CLI Connecting to the shelf manager CLI using a serial portFortiGate-5050 Shelf Alarm Panel To use the shelf manager command line interface agent Clia Power connection and configuration About data center DC powerRTN Connecting the FortiGate-5050 chassis to data center ground To connect the FortiGate-5050 chassis to data center groundFortiGate-5053 power converter tray front and back panel LEDBasic power requirements Redundant FortiGate-5050 power supplies Redundant FortiGate-5053 power converter traysRedundant FortiGate-5053 power converter trays FortiGate-5050-R Chassis Guide Red RTN to Black VDC to FortiGate-5053 Turning on FortiGate-5050 chassis power Wiring the FortiGate-5053 power converter trayAir flow Mounting the FortiGate-5050 chassisInserting 5000 series modules into a FortiGate-5050 chassis FortiGate-5050 hardware procedures Register your Fortinet product Customer service and technical supportFortinet documentation Vcci