FortiGate-5050 front panel

FortiGate-5050 chassis

FortiGate-5050 front panel

Figure 1 shows the front of a FortiGate-5050 chassis. Two FortiSwitch-5003 boards are installed in slots 1 and 2. Three FortiGate-5001SX boards are installed in slots 3, 4, and 5.

The FortiGate-5050 primary and secondary Shelf Managers and the Shelf Alarm Panel (SAP) are also visible. The factory installed shelf alarm panel displays alarms, provides a telco alarm interface, and also provides serial connections to the shelf managers. The factory installed shelf managers provide power distribution, cooling, alarms, and shelf status for the FortiGate-5050 chassis. For more information about these components, see “FortiGate-5050 shelf alarm panel” on page 9 and “FortiGate-5050 shelf managers” on page 8.

Figure 1: FortiGate-5050 front panel with FortiGate-5001SX and FortiSwitch-5003 boards installed

FortiGate-5001SX

boards

slots 3, 4,

and 5

FortiSwitch-5003

boards

slots 1 and 2

5

CONSOLE

USB

1

2

3

4

5

6

7

8

 

PWR ACC

 

 

 

 

 

 

 

 

STA

IPM

4

CONSOLE

USB

1

2

3

4

5

6

7

8

 

PWR ACC

 

 

 

 

 

 

 

 

STA

IPM

3

 

CONSOLE

USB

 

1

2

3

 

 

4

 

 

 

5

 

 

6

 

 

7

 

8

Hot-swappable

PWR ACC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STA IPM

 

MANAGEMENT

TE H O

 

SR 2 3 2

Z R E 0

Z R E 1

Z R E 2

 

 

 

 

 

 

 

 

 

 

CLK OK

EXT INT FLT FLT

HOT SWAP

 

 

cooling fan tray

2

SYSTEM CONSOLE

E2 E1

14 15

12 13

10 11

8 9

6 7

4 5

2 3

0 1

ZRE

RESET

LEDMODE

POWER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power LED

1

MANAGEMENT

ET H O

SYSTEM

CONSOLE

RS 2 3 2

RZ E 0

RZ E 1

RZ E 2

E2 E1

14 15

12 13

10 11

8 9

6 7

4 5

2 3

0 1

ZRE

CLK OK

EXT INT FLT FLT

SWAPHOT

RESET

LED MODE

SMC

2

5000SM

ETH1

link/Act

ETH0

10/100

link/Act

 

10/100

Service

ETH0

 

STATUS

Hot Swap

 

5050SAP

 

5000SM

ETH0

Service

 

STATUS

Hot Swap

SMC

 

 

 

ETH0 ETH1

10/100

 

RESET

SERIAL

ALARM

SERIAL

link/Act

RESET

10/100

1

1

2

link/Act

 

 

 

 

 

 

 

 

 

 

 

 

 

Secondary

 

ESD socket

Shelf Alarm

Primary

Shelf Manager

Panel (SAP)

Shelf Manager

(SMC 2)

 

(SMC 1)

Also visible on the front of the FortiGate-5050:

The location of the hot swappable FortiGate-5050 cooling fan tray behind panel.

Power LED.

ESD socket, used for connecting an ESD wrist or ankle band when working with the chassis.

Caution: Do not operate the FortiGate-5050 chassis with open slots on the front panel. For optimum cooling performance and safety, the slots must contain a FortiGate-5000 series board or an air baffle slot filler. As well the removable power supply panel must be installed over the power connectors on the back of the chassis.

FortiGate-5050-R Chassis Guide

601-30000-87717-20090108http://docs.fortinet.com/ Feedback

Image 6
Contents FortiGate-5050-R FortiGate-5050-R Chassis Guide Contents Contents FortiGate-5050-R Chassis Guide FortiGate-5050 chassis Power LED FortiGate-5050 front panelFortiGate-5050 back panel RTMPhysical description of the FortiGate-5050 chassis FortiGate-5050 shelf managersFortiGate-5050 shelf alarm panel Shelf Manager fan and power controlUSER3 Shelf alarm panel telco alarms 5050SAPShelf manager command line interface CLI Connecting to the shelf manager CLI using a serial portFortiGate-5050 Shelf Alarm Panel To use the shelf manager command line interface agent Clia Power connection and configuration About data center DC powerRTN Connecting the FortiGate-5050 chassis to data center ground To connect the FortiGate-5050 chassis to data center groundFortiGate-5053 power converter tray front and back panel LEDBasic power requirements Redundant FortiGate-5050 power supplies Redundant FortiGate-5053 power converter traysRedundant FortiGate-5053 power converter trays FortiGate-5050-R Chassis Guide Red RTN to Black VDC to FortiGate-5053 Turning on FortiGate-5050 chassis power Wiring the FortiGate-5053 power converter trayMounting the FortiGate-5050 chassis Inserting 5000 series modules into a FortiGate-5050 chassisAir flow FortiGate-5050 hardware procedures Customer service and technical support Fortinet documentationRegister your Fortinet product Vcci