Fortinet 5050-R manual To use the shelf manager command line interface agent Clia

Page 14

Shelf manager command line interface (CLI)

FortiGate-5050 chassis

2Enter and confirm a new password for the root account.

The password should be between 5 and 8 characters long and should include a combination of upper and lower case letters and numbers.

You can use the passwd command to change the root account password at any time.

You can also use the passwd command to remove the root account. Enter the passwd command and when prompted for a password, press enter to add a blank password.

To use the shelf manager command line interface agent (CLIA)

Once you have logged into the shelf manager CLI you use the Command Line Interface Agent (CLIA) to enter shelf manager commands. Usually you do this from the Linux command line by entering clia followed by the required CLIA command verb and parameters. The CLIA executable connects to the main Shelf Manager software process, passes the command information to it and retrieves the results.

For example, you can enter the following command to list the most commonly used CLIA commands:

clia help

You can also the help command to get more information about specific CLIA commands. For example, use the following command display help for the shelf pwrreorder command:

clia help shelf pwrreorder

Pigeon Point Shelf Manager Command Line Interpreter

Change the order of FRU Activation and Power Descriptors instead of <addr> <fru_id> user may use:

board <N> shm <N>

power_supply <N> (valid in 2.x systems only) fan_tray <N>

PwrReorder <addr1> <fru_id1> before/after <addr2> <fru_id2>

FortiGate-5050-R Chassis Guide

1401-30000-87717-20090108http://docs.fortinet.com/ Feedback

Image 14
Contents FortiGate-5050-R FortiGate-5050-R Chassis Guide Contents Contents FortiGate-5050-R Chassis Guide FortiGate-5050 chassis Power LED FortiGate-5050 front panelFortiGate-5050 back panel RTMPhysical description of the FortiGate-5050 chassis FortiGate-5050 shelf managersFortiGate-5050 shelf alarm panel Shelf Manager fan and power controlUSER3 Shelf alarm panel telco alarms 5050SAPShelf manager command line interface CLI Connecting to the shelf manager CLI using a serial portFortiGate-5050 Shelf Alarm Panel To use the shelf manager command line interface agent Clia Power connection and configuration About data center DC powerRTN Connecting the FortiGate-5050 chassis to data center ground To connect the FortiGate-5050 chassis to data center groundFortiGate-5053 power converter tray front and back panel LEDBasic power requirements Redundant FortiGate-5050 power supplies Redundant FortiGate-5053 power converter traysRedundant FortiGate-5053 power converter trays FortiGate-5050-R Chassis Guide Red RTN to Black VDC to FortiGate-5053 Turning on FortiGate-5050 chassis power Wiring the FortiGate-5053 power converter trayAir flow Mounting the FortiGate-5050 chassisInserting 5000 series modules into a FortiGate-5050 chassis FortiGate-5050 hardware procedures Register your Fortinet product Customer service and technical supportFortinet documentation Vcci