Fortinet 5050-R Physical description of the FortiGate-5050 chassis, FortiGate-5050 shelf managers

Page 8

Physical description of the FortiGate-5050 chassis

FortiGate-5050 chassis

Physical description of the FortiGate-5050 chassis

The FortiGate-5050 chassis is a 5U chassis that can be installed in a standard 19-inch rack. Table 1 describes the physical characteristics of the FortiGate-5050 chassis.

Table 1: FortiGate-5050 chassis physical description

Dimensions

8.75 x 17 x 15.5 in. (13.3 x 43.2 x 39.4 cm)

 

(H x W x D)

 

 

Shipping weight

26.75 lb. (12.1 kg)

completely assembled

 

with packaging

 

 

 

Operating environment

Temperature: 32 to 104°F (0 to 45°C)

 

 

 

Relative humidity: 5 to 85% (Non-condensing)

 

 

Storage environment

Temperature: -13 to 158 °F (-25 to 70°C)

 

 

 

Relative humidity: 5 to 95% (Non-condensing)

 

 

Power consumption

Maximum: 1,135 W

 

 

Power input

2x redundant -48VDC to -58VDC

 

 

FortiGate-5050 shelf managers

The FortiGate-5050 chassis includes one or two redundant hot-swappable shelf managers, located in the dedicated shelf manager slots on the bottom of the FortiGate-5050 front panel. The primary shelf manager is installed on the right (SMC 1) the secondary shelf manager is installed on the left (SMC 2).

The shelf managers support redundant operation with automatic switchover. If both shelf managers are operating normally, one acts as the active shelf manager and the other as the standby. Usually the primary shelf manager would be the active shelf manager and the secondary shelf manager would be the standby shelf manager. The shelf managers monitor each other and either can trigger a switchover if necessary. The active shelf manager performs all shelf manager functions. If the active shelf manager fails or is removed, the standby shelf manager takes over all shelf manager functions.

The FortiGate-5050 shelf managers control chassis power up and power down, chassis power distribution, monitor chassis operating parameters, monitor and control chassis cooling, and can signal alarms if the chassis encounters problems. All FortiGate-5000 modules installed in the chassis communicate with the shelf managers.

The FortiGate-5050 shelf managers are factory installed. In most cases users do not have to install or configure the shelf managers.

Each shelf manager has two ethernet interfaces (ETH 0 and ETH 1). You can connect to ETH 0 from the shelf manager front panel. ETH 1 connects to the FortiGate-5050 backplane.

The shelf managers detect alarm conditions and communicate alarm signals to the FortiGate-5050 shelf alarm panel. The shelf alarm panel also contains serial interfaces for connecting to the shelf managers.

The shelf managers are hot swappable. You can remove a shelf manager by opening the extraction lever until the hot swap LED starts blinking. When the hot swap LED turns solid blue you can remove the shelf manager from the FortiGate-5050 chassis.

FortiGate-5050-R Chassis Guide

801-30000-87717-20090108http://docs.fortinet.com/ Feedback

Image 8
Contents FortiGate-5050-R FortiGate-5050-R Chassis Guide Contents Contents FortiGate-5050-R Chassis Guide FortiGate-5050 chassis Power LED FortiGate-5050 front panelFortiGate-5050 back panel RTMPhysical description of the FortiGate-5050 chassis FortiGate-5050 shelf managersFortiGate-5050 shelf alarm panel Shelf Manager fan and power controlUSER3 Shelf alarm panel telco alarms 5050SAPShelf manager command line interface CLI Connecting to the shelf manager CLI using a serial portFortiGate-5050 Shelf Alarm Panel To use the shelf manager command line interface agent Clia Power connection and configuration About data center DC powerRTN Connecting the FortiGate-5050 chassis to data center ground To connect the FortiGate-5050 chassis to data center groundFortiGate-5053 power converter tray front and back panel LEDBasic power requirements Redundant FortiGate-5050 power supplies Redundant FortiGate-5053 power converter traysRedundant FortiGate-5053 power converter trays FortiGate-5050-R Chassis Guide Red RTN to Black VDC to FortiGate-5053 Turning on FortiGate-5050 chassis power Wiring the FortiGate-5053 power converter trayAir flow Mounting the FortiGate-5050 chassisInserting 5000 series modules into a FortiGate-5050 chassis FortiGate-5050 hardware procedures Register your Fortinet product Customer service and technical supportFortinet documentation Vcci