EverFocus EFC--02-1-A user manual Hardware Installation, Mounting the Enclosure and Controller

Page 16

Chapter

2

Hardware Installation

In this chapter, after preparing for the installation, the user is ready to begin the install. This section will describe, in general terms, how to install the hardware. Here are the following processes:

Mount the enclosure (enclosure optional) and controller

Install and connect the card readers

Connect the electric strikes or mag locks

Connect the controller to the system computer and system reader (system reader optional)

Mount a backup battery in the enclosure (optional)

Mounting the Enclosure and Controller

The controller is an essential part of the access control system. We recommend mounting it in an EverAccess EPN-871-B metal enclosure (also sometimes referred to as a panel or a can). The controller should be mounted in a location that is convenient and easily accessible, but also secure. The controller acts as the brain of the access control system and can be used to make changes to the database. When choosing a location to mount the controller, choose a clean, dry location that will allow the administrator easy access to make changes to the system, but that can be secured from the general public. The enclosure must be mounted on a sturdy wall using fasteners or anchors (to be provided by the installer). If you are using an EverAccess EPN-871-B metal enclosure there must be an AC power outlet for the enclosure in order to power the controller. (The EverAccess EPN-871-B metal enclosure uses a 24 V AC power supply with a built in 12 V DC converter.) In addition, the system computer should be near the controller, so that the controller can be connected to the PC, allowing the administrator to utilize the Flex Series software. If the system requires additional door or alarm modules, install them in the controller before mounting the controller in the enclosure or on the wall.

Please Note: If the controller screw holes due not line up properly with the enclosure some filing may be needed for adjustment.

8

Image 16
Contents Flex Series Controller EFC-02-1A Instruction Guide Table of Contents Chapter Page ARM/DISARM Specifications FederalCommunication Commission Interference Statement Features Product OverviewParts List Controller Layout Controller Layout Main modulePage Installation Review Preparing for the InstallationObtain a Floor Plan Preparing for the InstallationDetermining Hardware and Location Entry Card Readers Hardware Installation Mounting the Enclosure and ControllerStep Installing a Module to Controller Install a New Module to ControllerTerminal / LED Definitions Reader/Door Index ConversionMain Module Terminal Definition Main Module LED Definition Terminal name Function No Terminal nameDoor Module Terminal Definition LED MeaningDoor Module LED Definition Definitions of the Door Module TerminalsAlarm Module Terminal Definition Terminal Function NameInstall and Connecting the Readers Alarm Module LED DefinitionRS232 Format Wiegand 26 FormatConnection to Door Lock Connection to an Electric StrikeConnection to Door Sensor Connection to a Magnetic LockConnection to Alarm Input Connection to Fire & Alarm InputConnection to Request-to-Exit Connection to Alarm Output 14 Connecting Alarm-sensor to Controller16 Normally Closed Connections for Alarm Output Connecting Controller Computer Connection to Computer via RS232Connection to Desktop Reader via RS485 RS485 Bus Based Networking SystemRS485 Bus Extension Connection to Multiple Controllers via RS485 Two Incorrect ConnectionsTCP/IP Based System Connection to Multiple Controllers via RS485Page Connecting Power Connecting the Power SupplyConnection to Backup Battery Mount a Backup Battery optionalReset Controller Cover Placement Before First UsePage Enter System Configuration General Operation GuidelineMain Setting Items Display the Number of Installed ModulesDisplay the Firmware Version Enter System Setting Menu System SettingSet Date Format Auto Daylight Savings Time Set DateSet Time Set Arm PIN Set System PINErase All Events Reset All Data and Settings Card SettingEnter Card Setting Menu Delete Cards Add CardsDelete a Card by Serial Number Set Card Properties Status SettingDelete All Cards Group Setting Access Right SettingSet Card PIN Setting Anti Passback APB Setting Reader Setting Enter Reader Setting MenuCard ARM Setting Show Card NumberKeypad Setting Reader to Door AllocationDoor Setting System Reader SettingEnter Door Setting Menu Open Time SettingSet Door Behavior at Fire Alarm Set Door Hold Open TimeComponents for Alarm Alarm SettingAlarm Configuration Basics Enter Alarm Setting Menu Alarm Setting Menu StructureEnter Alarm Action Setting Sub-menu Enter Extended Alarm Setting Sub-menu Fire AlarmSYS PIN Fail Zone Alarm 1~8ARM PIN Fail Alarm Remote AlarmUnknown Card Expired CardInvalid Card Invalid DoorInvalid Time Card Anti-Passback FailDoor Forced Open Card PIN FailDoor Held Open Armzone Setting Enter Alarm Time Setting Sub-menuEnter Armzone Setting Menu Reader LostSet ARM Delay Time Set Active ArmzoneAddress Setting Arm the System using the Controller KeypadDisarm the System using the Controller Keypad Clear the AlarmArm/Disarm the System using a Reader Yellow LED Status System ARM StatusPage Software Setup Install the Software in the Control ComputerSetup the User Accounts for the Software Configure the Controller and All Other HardwareEnroll Cards Page Page Page EverAccess

EFC--02-1-A specifications

The EverFocus EFC--02-1-A is an advanced video surveillance solution designed to meet the high demands of modern security systems. This device stands out for its robust features, cutting-edge technologies, and exceptional reliability, making it ideal for a wide range of surveillance applications, from retail environments to industrial facilities.

One of the primary features of the EFC--02-1-A is its superior image quality. Equipped with high-definition video capabilities, the camera can capture crystal-clear images even in low-light conditions, thanks to its advanced low-light technology. This ensures that vital details are recorded, enhancing the overall effectiveness of surveillance efforts. The device boasts a wide dynamic range (WDR), which allows it to handle scenes with both bright and dark areas, maintaining image clarity and detail regardless of lighting variations.

The EFC--02-1-A also supports multi-streaming capabilities, enabling simultaneous transmission of multiple video streams in different resolutions. This versatility is particularly advantageous for network bandwidth management, allowing users to customize their surveillance setup according to specific requirements. The integration of advanced compression technologies such as H.265 ensures efficient use of storage while maintaining high video quality.

Durability is another hallmark of the EFC--02-1-A. The camera is designed to withstand harsh environmental conditions, featuring an IP67-rated enclosure that protects it from dust and water ingress. This weatherproof design makes it suitable for both indoor and outdoor installations, ensuring uninterrupted operation in various settings.

Moreover, the EFC--02-1-A comes equipped with smart analytics capabilities, including motion detection and face recognition technologies. These features enhance the system’s functionality by enabling automatic alerts and efficient monitoring of specific areas, thereby reducing the workload for security personnel.

Lastly, seamless integration is a core characteristic of the EFC--02-1-A. It is compatible with multiple video management systems (VMS) and can easily connect with other security devices, promoting a holistic security ecosystem. This interoperability, coupled with user-friendly operational features and remote access capabilities, positions the EverFocus EFC--02-1-A as a leading choice for organizations aiming to enhance their surveillance setups.