EverFocus EFC--02-1-A user manual Disarm the System using the Controller Keypad, Clear the Alarm

Page 66

System Disarmed [ENT] to Arm

Press ENT to arm all active arm zones. The following message is displayed:

System Armed [ENT] to Disarm

Press CLR to exit. The controller will wait for the period of time defined as “alarm delay” and then arm all active arm zones.

Disarm the System using the Controller Keypad

In order to utilize this function, the user must have the ARM PIN and the card must be logged in as ARM enabled. Assume the system is in armed status. The user swipes the card to enter the door. The controller will disarm all active arm zones in arm delay time. For example, if the system is in armed status and a card is presented, the controller will disarm all active arm zones for the amount of time assigned as the arm delay. During this time, no alarm outputs will be generated even if an alarm input is triggered.

Similar to the procedure to arm the system, press ARM on the keypad. Enter the ARM password and press ENT to confirm. After the password is verified the current system ARM status will be displayed as shown below:

System Armed [ENT] to Disarm

Press ENT to disarm all active arm zones. The following message is displayed:

System Disarmed [ENT] to Arm

Press CLR to exit.

Clear the Alarm

When system is generating an active, ongoing alarm output, follow the procedure below to clear the alarm.

At the window showing system time, press ARM on the keypad. Enter the ARM password and press ENT to confirm. After password is verified the following menu window appears:

Reset Alarm? [ENT] to Reset

58

Image 66
Contents Flex Series Controller EFC-02-1A Instruction Guide Table of Contents Chapter Page ARM/DISARM Specifications FederalCommunication Commission Interference Statement Features Product OverviewParts List Controller Layout Controller Layout Main modulePage Installation Review Preparing for the InstallationPreparing for the Installation Obtain a Floor PlanDetermining Hardware and Location Entry Card Readers Hardware Installation Mounting the Enclosure and ControllerStep Installing a Module to Controller Install a New Module to ControllerReader/Door Index Conversion Terminal / LED DefinitionsMain Module Terminal Definition Main Module LED Definition Terminal name Function No Terminal nameDoor Module Terminal Definition LED MeaningDoor Module LED Definition Definitions of the Door Module TerminalsAlarm Module Terminal Definition Terminal Function NameInstall and Connecting the Readers Alarm Module LED DefinitionRS232 Format Wiegand 26 FormatConnection to Door Lock Connection to an Electric StrikeConnection to Door Sensor Connection to a Magnetic LockConnection to Fire & Alarm Input Connection to Alarm InputConnection to Request-to-Exit Connection to Alarm Output 14 Connecting Alarm-sensor to Controller16 Normally Closed Connections for Alarm Output Connecting Controller Computer Connection to Computer via RS232Connection to Desktop Reader via RS485 RS485 Bus Based Networking SystemRS485 Bus Extension Connection to Multiple Controllers via RS485 Two Incorrect ConnectionsTCP/IP Based System Connection to Multiple Controllers via RS485Page Connecting Power Connecting the Power SupplyMount a Backup Battery optional Connection to Backup BatteryReset Controller Cover Placement Before First UsePage Enter System Configuration General Operation GuidelineDisplay the Number of Installed Modules Main Setting ItemsDisplay the Firmware Version System Setting Enter System Setting MenuSet Date Format Set Date Auto Daylight Savings TimeSet Time Set System PIN Set Arm PINErase All Events Card Setting Reset All Data and SettingsEnter Card Setting Menu Add Cards Delete CardsDelete a Card by Serial Number Status Setting Set Card PropertiesDelete All Cards Access Right Setting Group SettingSet Card PIN Setting Anti Passback APB Setting Card ARM Setting Reader SettingEnter Reader Setting Menu Show Card NumberKeypad Setting Reader to Door AllocationEnter Door Setting Menu Door SettingSystem Reader Setting Open Time SettingSet Door Behavior at Fire Alarm Set Door Hold Open TimeAlarm Setting Components for AlarmAlarm Configuration Basics Enter Alarm Setting Menu Alarm Setting Menu StructureEnter Alarm Action Setting Sub-menu Enter Extended Alarm Setting Sub-menu Fire AlarmZone Alarm 1~8 SYS PIN FailARM PIN Fail Unknown Card AlarmRemote Alarm Expired CardInvalid Time Invalid CardInvalid Door Card Anti-Passback FailCard PIN Fail Door Forced OpenDoor Held Open Enter Armzone Setting Menu Armzone SettingEnter Alarm Time Setting Sub-menu Reader LostSet ARM Delay Time Set Active ArmzoneAddress Setting Arm the System using the Controller KeypadDisarm the System using the Controller Keypad Clear the AlarmArm/Disarm the System using a Reader Yellow LED Status System ARM StatusPage Software Setup Install the Software in the Control ComputerSetup the User Accounts for the Software Configure the Controller and All Other HardwareEnroll Cards Page Page Page EverAccess

EFC--02-1-A specifications

The EverFocus EFC--02-1-A is an advanced video surveillance solution designed to meet the high demands of modern security systems. This device stands out for its robust features, cutting-edge technologies, and exceptional reliability, making it ideal for a wide range of surveillance applications, from retail environments to industrial facilities.

One of the primary features of the EFC--02-1-A is its superior image quality. Equipped with high-definition video capabilities, the camera can capture crystal-clear images even in low-light conditions, thanks to its advanced low-light technology. This ensures that vital details are recorded, enhancing the overall effectiveness of surveillance efforts. The device boasts a wide dynamic range (WDR), which allows it to handle scenes with both bright and dark areas, maintaining image clarity and detail regardless of lighting variations.

The EFC--02-1-A also supports multi-streaming capabilities, enabling simultaneous transmission of multiple video streams in different resolutions. This versatility is particularly advantageous for network bandwidth management, allowing users to customize their surveillance setup according to specific requirements. The integration of advanced compression technologies such as H.265 ensures efficient use of storage while maintaining high video quality.

Durability is another hallmark of the EFC--02-1-A. The camera is designed to withstand harsh environmental conditions, featuring an IP67-rated enclosure that protects it from dust and water ingress. This weatherproof design makes it suitable for both indoor and outdoor installations, ensuring uninterrupted operation in various settings.

Moreover, the EFC--02-1-A comes equipped with smart analytics capabilities, including motion detection and face recognition technologies. These features enhance the system’s functionality by enabling automatic alerts and efficient monitoring of specific areas, thereby reducing the workload for security personnel.

Lastly, seamless integration is a core characteristic of the EFC--02-1-A. It is compatible with multiple video management systems (VMS) and can easily connect with other security devices, promoting a holistic security ecosystem. This interoperability, coupled with user-friendly operational features and remote access capabilities, positions the EverFocus EFC--02-1-A as a leading choice for organizations aiming to enhance their surveillance setups.