EverFocus EFC--02-1-A Arm/Disarm the System using a Reader, Yellow LED Status System ARM Status

Page 67

Press ENT to clear the alarm. If system is currently armed user will be prompted to disarm the system first. Please refer to previous section for how to disarm the system.

Arm/Disarm the System using a Reader

The whole system can also be armed and disarmed using a keypad reader. (The reader must have an integrated keypad, and the keypad and system reader settings must be enabled on the controller in order to utilize this feature. Please refer to subsection “Reader Setting” for instructions on enabling these features.) The part number for the EverAccess keypad reader is ERK-871.

The user must first enter a command to get into the arm operation mode. (The command is introduced in step 1 below.) In the arm operation mode, the yellow LED on the ERK-871 will show the four different system modes outlined below:

Yellow LED Status

System ARM Status

OFF

Indicates that the system is disarmed

 

 

ON

Indicates that the system is armed

 

 

Flashing Slowly

Indicates that the system is in arm delay period

 

 

Flashing Quickly

Indicates that the system is armed and some alarm

 

input has triggered the alarm output.

The steps to arm or disarm the system at a keypad reader are as follows:

1. Press # 0 0 1 # followed by the 6-pin ARM PIN. Press # again

2. The reader is now in the arm operation mode.

3. If the system is in disarmed mode (the yellow LED is OFF), press 1 to arm the system. The system will enter the arm delay period (the yellow LED will slowly flash).

Note: The system will not enter the arm delay period, if an alarm input is active when the user attempts to arm the system. In other words, after

1is pressed, if the yellow LED remains off, the system cannot enter the arm delay period because an alarm input is active.

If the system is in armed mode (the yellow LED is ON) or in the arm delay period (the yellow LED is flashing slowly), press 1 to disarm the system. Then the system will enter the disarmed mode (the yellow LED will be off).

If the system is in alarm triggered mode (the yellow LED is flashing quickly), press 1 to clear the alarm. Then the system will get into the armed mode (the yellow LED will be on)

59

Image 67
Contents Flex Series Controller EFC-02-1A Instruction Guide Table of Contents Chapter Page ARM/DISARM Specifications FederalCommunication Commission Interference Statement Product Overview FeaturesParts List Controller Layout Main module Controller LayoutPage Preparing for the Installation Installation ReviewObtain a Floor Plan Preparing for the InstallationDetermining Hardware and Location Entry Card Readers Mounting the Enclosure and Controller Hardware InstallationStep Install a New Module to Controller Installing a Module to ControllerTerminal / LED Definitions Reader/Door Index ConversionMain Module Terminal Definition Terminal name Function No Terminal name Main Module LED DefinitionLED Meaning Door Module Terminal DefinitionDefinitions of the Door Module Terminals Door Module LED DefinitionTerminal Function Name Alarm Module Terminal DefinitionAlarm Module LED Definition Install and Connecting the ReadersWiegand 26 Format RS232 FormatConnection to an Electric Strike Connection to Door LockConnection to a Magnetic Lock Connection to Door SensorConnection to Alarm Input Connection to Fire & Alarm InputConnection to Request-to-Exit 14 Connecting Alarm-sensor to Controller Connection to Alarm Output16 Normally Closed Connections for Alarm Output Connection to Computer via RS232 Connecting Controller ComputerRS485 Bus Based Networking System Connection to Desktop Reader via RS485RS485 Bus Extension Two Incorrect Connections Connection to Multiple Controllers via RS485Connection to Multiple Controllers via RS485 TCP/IP Based SystemPage Connecting the Power Supply Connecting PowerConnection to Backup Battery Mount a Backup Battery optionalReset Controller Before First Use Cover PlacementPage General Operation Guideline Enter System ConfigurationMain Setting Items Display the Number of Installed ModulesDisplay the Firmware Version Enter System Setting Menu System SettingSet Date Format Auto Daylight Savings Time Set DateSet Time Set Arm PIN Set System PINErase All Events Reset All Data and Settings Card SettingEnter Card Setting Menu Delete Cards Add CardsDelete a Card by Serial Number Set Card Properties Status SettingDelete All Cards Group Setting Access Right SettingSet Card PIN Setting Anti Passback APB Setting Show Card Number Reader SettingEnter Reader Setting Menu Card ARM SettingReader to Door Allocation Keypad SettingOpen Time Setting Door SettingSystem Reader Setting Enter Door Setting MenuSet Door Hold Open Time Set Door Behavior at Fire AlarmComponents for Alarm Alarm SettingAlarm Configuration Basics Alarm Setting Menu Structure Enter Alarm Setting MenuEnter Alarm Action Setting Sub-menu Fire Alarm Enter Extended Alarm Setting Sub-menuSYS PIN Fail Zone Alarm 1~8ARM PIN Fail Expired Card AlarmRemote Alarm Unknown CardCard Anti-Passback Fail Invalid CardInvalid Door Invalid TimeDoor Forced Open Card PIN FailDoor Held Open Reader Lost Armzone SettingEnter Alarm Time Setting Sub-menu Enter Armzone Setting MenuSet Active Armzone Set ARM Delay TimeArm the System using the Controller Keypad Address SettingClear the Alarm Disarm the System using the Controller KeypadYellow LED Status System ARM Status Arm/Disarm the System using a ReaderPage Install the Software in the Control Computer Software SetupConfigure the Controller and All Other Hardware Setup the User Accounts for the SoftwareEnroll Cards Page Page Page EverAccess

EFC--02-1-A specifications

The EverFocus EFC--02-1-A is an advanced video surveillance solution designed to meet the high demands of modern security systems. This device stands out for its robust features, cutting-edge technologies, and exceptional reliability, making it ideal for a wide range of surveillance applications, from retail environments to industrial facilities.

One of the primary features of the EFC--02-1-A is its superior image quality. Equipped with high-definition video capabilities, the camera can capture crystal-clear images even in low-light conditions, thanks to its advanced low-light technology. This ensures that vital details are recorded, enhancing the overall effectiveness of surveillance efforts. The device boasts a wide dynamic range (WDR), which allows it to handle scenes with both bright and dark areas, maintaining image clarity and detail regardless of lighting variations.

The EFC--02-1-A also supports multi-streaming capabilities, enabling simultaneous transmission of multiple video streams in different resolutions. This versatility is particularly advantageous for network bandwidth management, allowing users to customize their surveillance setup according to specific requirements. The integration of advanced compression technologies such as H.265 ensures efficient use of storage while maintaining high video quality.

Durability is another hallmark of the EFC--02-1-A. The camera is designed to withstand harsh environmental conditions, featuring an IP67-rated enclosure that protects it from dust and water ingress. This weatherproof design makes it suitable for both indoor and outdoor installations, ensuring uninterrupted operation in various settings.

Moreover, the EFC--02-1-A comes equipped with smart analytics capabilities, including motion detection and face recognition technologies. These features enhance the system’s functionality by enabling automatic alerts and efficient monitoring of specific areas, thereby reducing the workload for security personnel.

Lastly, seamless integration is a core characteristic of the EFC--02-1-A. It is compatible with multiple video management systems (VMS) and can easily connect with other security devices, promoting a holistic security ecosystem. This interoperability, coupled with user-friendly operational features and remote access capabilities, positions the EverFocus EFC--02-1-A as a leading choice for organizations aiming to enhance their surveillance setups.