EverFocus EFC--02-1-A TCP/IP Based System, Connection to Multiple Controllers via RS485

Page 35

EverAccess

POWERCARD TX RX

8

3

2

1

1

10

10

11

11

12

12

Fig. 3.8 Connection to Multiple Controllers via RS485

TCP/IP Based System

It is also possible to network the controller via TCP/IP in order to remotely manage the controller over internet or intranet. This is accomplished using the EverAccess LAN adaptor (part number EA-LAN1) to convert RS232 /RS485 signals to TCP/IP. Fig. 3.9 diagrams this type of installation.

TCP/IP

WAN/LAN

TCP/IP

RS485

 

 

 

 

 

 

 

RS485 to TCP/IP

EverAccess

EverAccess

 

 

converter

 

 

 

 

 

Controller

Controller

Figure 3.9 Diagram for TCP/IP based System

The following is a step by step guide to setting up an EA-LAN1 network adaptor.

Step 1: Install the EA-LAN1 software on the Installation PC using the CD included with the EA-LAN1. Make sure that the installation PC is connected to the network that will be used to manage the controller.

Step 2: Connect the EA-LAN1 to the local area network using a LAN cable, and power up the EA-LAN1.

27

Image 35
Contents Flex Series Controller EFC-02-1A Instruction Guide Table of Contents Chapter Page ARM/DISARM Specifications FederalCommunication Commission Interference Statement Product Overview FeaturesParts List Controller Layout Main module Controller LayoutPage Preparing for the Installation Installation ReviewDetermining Hardware and Location Preparing for the InstallationObtain a Floor Plan Entry Card Readers Mounting the Enclosure and Controller Hardware InstallationStep Install a New Module to Controller Installing a Module to ControllerMain Module Terminal Definition Reader/Door Index ConversionTerminal / LED Definitions Terminal name Function No Terminal name Main Module LED DefinitionLED Meaning Door Module Terminal DefinitionDefinitions of the Door Module Terminals Door Module LED DefinitionTerminal Function Name Alarm Module Terminal DefinitionAlarm Module LED Definition Install and Connecting the ReadersWiegand 26 Format RS232 FormatConnection to an Electric Strike Connection to Door LockConnection to a Magnetic Lock Connection to Door SensorConnection to Request-to-Exit Connection to Fire & Alarm InputConnection to Alarm Input 14 Connecting Alarm-sensor to Controller Connection to Alarm Output16 Normally Closed Connections for Alarm Output Connection to Computer via RS232 Connecting Controller ComputerRS485 Bus Based Networking System Connection to Desktop Reader via RS485RS485 Bus Extension Two Incorrect Connections Connection to Multiple Controllers via RS485Connection to Multiple Controllers via RS485 TCP/IP Based SystemPage Connecting the Power Supply Connecting PowerReset Controller Mount a Backup Battery optionalConnection to Backup Battery Before First Use Cover PlacementPage General Operation Guideline Enter System ConfigurationDisplay the Firmware Version Display the Number of Installed ModulesMain Setting Items Set Date Format System SettingEnter System Setting Menu Set Time Set DateAuto Daylight Savings Time Erase All Events Set System PINSet Arm PIN Enter Card Setting Menu Card SettingReset All Data and Settings Delete a Card by Serial Number Add CardsDelete Cards Delete All Cards Status SettingSet Card Properties Set Card PIN Setting Access Right SettingGroup Setting Anti Passback APB Setting Show Card Number Reader SettingEnter Reader Setting Menu Card ARM SettingReader to Door Allocation Keypad SettingOpen Time Setting Door SettingSystem Reader Setting Enter Door Setting MenuSet Door Hold Open Time Set Door Behavior at Fire AlarmAlarm Configuration Basics Alarm SettingComponents for Alarm Alarm Setting Menu Structure Enter Alarm Setting MenuEnter Alarm Action Setting Sub-menu Fire Alarm Enter Extended Alarm Setting Sub-menuARM PIN Fail Zone Alarm 1~8SYS PIN Fail Expired Card AlarmRemote Alarm Unknown CardCard Anti-Passback Fail Invalid CardInvalid Door Invalid TimeDoor Held Open Card PIN FailDoor Forced Open Reader Lost Armzone SettingEnter Alarm Time Setting Sub-menu Enter Armzone Setting MenuSet Active Armzone Set ARM Delay TimeArm the System using the Controller Keypad Address SettingClear the Alarm Disarm the System using the Controller KeypadYellow LED Status System ARM Status Arm/Disarm the System using a ReaderPage Install the Software in the Control Computer Software SetupConfigure the Controller and All Other Hardware Setup the User Accounts for the SoftwareEnroll Cards Page Page Page EverAccess

EFC--02-1-A specifications

The EverFocus EFC--02-1-A is an advanced video surveillance solution designed to meet the high demands of modern security systems. This device stands out for its robust features, cutting-edge technologies, and exceptional reliability, making it ideal for a wide range of surveillance applications, from retail environments to industrial facilities.

One of the primary features of the EFC--02-1-A is its superior image quality. Equipped with high-definition video capabilities, the camera can capture crystal-clear images even in low-light conditions, thanks to its advanced low-light technology. This ensures that vital details are recorded, enhancing the overall effectiveness of surveillance efforts. The device boasts a wide dynamic range (WDR), which allows it to handle scenes with both bright and dark areas, maintaining image clarity and detail regardless of lighting variations.

The EFC--02-1-A also supports multi-streaming capabilities, enabling simultaneous transmission of multiple video streams in different resolutions. This versatility is particularly advantageous for network bandwidth management, allowing users to customize their surveillance setup according to specific requirements. The integration of advanced compression technologies such as H.265 ensures efficient use of storage while maintaining high video quality.

Durability is another hallmark of the EFC--02-1-A. The camera is designed to withstand harsh environmental conditions, featuring an IP67-rated enclosure that protects it from dust and water ingress. This weatherproof design makes it suitable for both indoor and outdoor installations, ensuring uninterrupted operation in various settings.

Moreover, the EFC--02-1-A comes equipped with smart analytics capabilities, including motion detection and face recognition technologies. These features enhance the system’s functionality by enabling automatic alerts and efficient monitoring of specific areas, thereby reducing the workload for security personnel.

Lastly, seamless integration is a core characteristic of the EFC--02-1-A. It is compatible with multiple video management systems (VMS) and can easily connect with other security devices, promoting a holistic security ecosystem. This interoperability, coupled with user-friendly operational features and remote access capabilities, positions the EverFocus EFC--02-1-A as a leading choice for organizations aiming to enhance their surveillance setups.