EverFocus EFC--02-1-A user manual Set Card Properties, Delete All Cards, Status Setting

Page 48
Press ENT

Delete All Cards

All cards can be deleted at once. At the following window:

Delete All Cards

Press ENT and system will prompt the user to confirm deletion:

Are You Sure ? [ENT] to Confirm

Press ENT again to delete all cards.

Caution: this operation will permanently delete ALL cards from the controller database.

Set Card Properties

Under the Card Setting menu, press twice to bring up the following window:

Set Card

Properties

Press ENT and system will prompt the user to enter serial number, as shown below:

Card Serial #:

________

After entering the serial number, press ENT to enter the submenu for setting card

properties. Each card has 6 properties that can be modified. Use and to choose desired properties.

Status Setting

A card can be set as enabled or disabled at the following submenu:

Status Setting

and system will show the status of current card as the figure below. Press ENT to toggle between the two statuses. Press CLR to exit without effecting any change.

Card Disabled [ENT] to Toggle

Card Enabled [ENT] to Toggle

40

Image 48
Contents Flex Series Controller EFC-02-1A Instruction Guide Table of Contents Chapter Page ARM/DISARM Specifications FederalCommunication Commission Interference Statement Features Product OverviewParts List Controller Layout Controller Layout Main modulePage Installation Review Preparing for the InstallationPreparing for the Installation Obtain a Floor PlanDetermining Hardware and Location Entry Card Readers Hardware Installation Mounting the Enclosure and ControllerStep Installing a Module to Controller Install a New Module to ControllerReader/Door Index Conversion Terminal / LED DefinitionsMain Module Terminal Definition Main Module LED Definition Terminal name Function No Terminal nameDoor Module Terminal Definition LED MeaningDoor Module LED Definition Definitions of the Door Module TerminalsAlarm Module Terminal Definition Terminal Function NameInstall and Connecting the Readers Alarm Module LED DefinitionRS232 Format Wiegand 26 FormatConnection to Door Lock Connection to an Electric StrikeConnection to Door Sensor Connection to a Magnetic LockConnection to Fire & Alarm Input Connection to Alarm InputConnection to Request-to-Exit Connection to Alarm Output 14 Connecting Alarm-sensor to Controller16 Normally Closed Connections for Alarm Output Connecting Controller Computer Connection to Computer via RS232Connection to Desktop Reader via RS485 RS485 Bus Based Networking SystemRS485 Bus Extension Connection to Multiple Controllers via RS485 Two Incorrect ConnectionsTCP/IP Based System Connection to Multiple Controllers via RS485Page Connecting Power Connecting the Power SupplyMount a Backup Battery optional Connection to Backup BatteryReset Controller Cover Placement Before First UsePage Enter System Configuration General Operation GuidelineDisplay the Number of Installed Modules Main Setting ItemsDisplay the Firmware Version System Setting Enter System Setting MenuSet Date Format Set Date Auto Daylight Savings TimeSet Time Set System PIN Set Arm PINErase All Events Card Setting Reset All Data and SettingsEnter Card Setting Menu Add Cards Delete CardsDelete a Card by Serial Number Status Setting Set Card PropertiesDelete All Cards Access Right Setting Group SettingSet Card PIN Setting Anti Passback APB Setting Reader Setting Enter Reader Setting MenuCard ARM Setting Show Card NumberKeypad Setting Reader to Door AllocationDoor Setting System Reader SettingEnter Door Setting Menu Open Time SettingSet Door Behavior at Fire Alarm Set Door Hold Open TimeAlarm Setting Components for AlarmAlarm Configuration Basics Enter Alarm Setting Menu Alarm Setting Menu StructureEnter Alarm Action Setting Sub-menu Enter Extended Alarm Setting Sub-menu Fire AlarmZone Alarm 1~8 SYS PIN FailARM PIN Fail Alarm Remote AlarmUnknown Card Expired CardInvalid Card Invalid DoorInvalid Time Card Anti-Passback FailCard PIN Fail Door Forced OpenDoor Held Open Armzone Setting Enter Alarm Time Setting Sub-menuEnter Armzone Setting Menu Reader LostSet ARM Delay Time Set Active ArmzoneAddress Setting Arm the System using the Controller KeypadDisarm the System using the Controller Keypad Clear the AlarmArm/Disarm the System using a Reader Yellow LED Status System ARM StatusPage Software Setup Install the Software in the Control ComputerSetup the User Accounts for the Software Configure the Controller and All Other HardwareEnroll Cards Page Page Page EverAccess

EFC--02-1-A specifications

The EverFocus EFC--02-1-A is an advanced video surveillance solution designed to meet the high demands of modern security systems. This device stands out for its robust features, cutting-edge technologies, and exceptional reliability, making it ideal for a wide range of surveillance applications, from retail environments to industrial facilities.

One of the primary features of the EFC--02-1-A is its superior image quality. Equipped with high-definition video capabilities, the camera can capture crystal-clear images even in low-light conditions, thanks to its advanced low-light technology. This ensures that vital details are recorded, enhancing the overall effectiveness of surveillance efforts. The device boasts a wide dynamic range (WDR), which allows it to handle scenes with both bright and dark areas, maintaining image clarity and detail regardless of lighting variations.

The EFC--02-1-A also supports multi-streaming capabilities, enabling simultaneous transmission of multiple video streams in different resolutions. This versatility is particularly advantageous for network bandwidth management, allowing users to customize their surveillance setup according to specific requirements. The integration of advanced compression technologies such as H.265 ensures efficient use of storage while maintaining high video quality.

Durability is another hallmark of the EFC--02-1-A. The camera is designed to withstand harsh environmental conditions, featuring an IP67-rated enclosure that protects it from dust and water ingress. This weatherproof design makes it suitable for both indoor and outdoor installations, ensuring uninterrupted operation in various settings.

Moreover, the EFC--02-1-A comes equipped with smart analytics capabilities, including motion detection and face recognition technologies. These features enhance the system’s functionality by enabling automatic alerts and efficient monitoring of specific areas, thereby reducing the workload for security personnel.

Lastly, seamless integration is a core characteristic of the EFC--02-1-A. It is compatible with multiple video management systems (VMS) and can easily connect with other security devices, promoting a holistic security ecosystem. This interoperability, coupled with user-friendly operational features and remote access capabilities, positions the EverFocus EFC--02-1-A as a leading choice for organizations aiming to enhance their surveillance setups.