3GENERAL SET

Setting RS-232C and RS-485

Set when connected to a PC through the rear panel RS-232C terminal or when connected to a system controller through the RS-485 terminal (A, B).

To perform PPP settings (modem), set to RS-485.

The DATA SPEED setting is for the RS-485. Set the PPP dialing speed in “BAUD RATE” in the <PPP SET> screen.

1 Press the [MENU] button.

The MENU indicator lights up and the <MAIN MENU> is displayed.

MENU

2 Turn the jog dial to select “3.GENERAL

SET” and then turn the shuttle dial clockwise.

The <GENERAL SET> screen is displayed.

3 Turn the jog dial to select “4.RS-232C/ RS-485 SET” and then turn the shuttle dial clockwise.

The <RS-232C/RS-485 SET> screen is displayed.

<RS-232C/RS-485

SET>

CONTROL

:

RS-485

DATA SPEED

:

19200

STATUS INFO

:

OFF

ALARM INFO

:

OFF

ADDRESS

:

001

4 Turn the shuttle dial clockwise.

“RS-485” flashes.

<RS-232C/RS-485 SET>

CONTROL

: RS-485

DATA SPEED

: 19200

STATUS INFO

: OFF

ALARM INFO

: OFF

ADDRESS

: 001

5 Turn the jog dial to select “RS-232C” or “RS-485” and then turn the shuttle dial clockwise.

The cursor moves to “DATA SPEED”.

<RS-232C/RS-485 SET>

CONTROL

: RS-485

DATA SPEED

: 19200

STATUS INFO

: OFF

ALARM INFO

: OFF

ADDRESS

: 001

[Settings] (‹ indicates default setting)

Setting

Description

Camera control (SANYO + other companies’) from the DVR unit enabled

Camera control (SANYO + other companies’)

‹RS-485 from the network enabled

Camera control (SANYO + other companies’) from the controller enabled

PC connected to RS-232C cannot be used

Camera control (other companies’) from the DVR unit enabled

Camera control (other companies’) from the RS-232C network enabled

Controller cannot be used

The DVR operations from a PC connected to RS-232C are enabled

6 Turn the shuttle dial clockwise.

“19200” flashes.

<RS-232C/RS-485 SET>

CONTROL

: RS-485

DATA SPEED

: 19200

STATUS INFO

: OFF

ALARM INFO

: OFF

ADDRESS

: 001

7 Turn the jog dial to select the “DATA SPEED” setting and then turn the shuttle dial clockwise.

Settings are complete if “RS-232C” is selected for “CONTROL”. Press the [EXIT/OSD] button.

If “RS-485” is selected, proceed to the next step.

<RS-232C/RS-485 SET>

CONTROL

: RS-485

DATA SPEED

: 19200

 

 

STATUS INFO

: OFF

ALARM INFO

: OFF

ADDRESS

: 001

[Settings] (‹ indicates default setting)

Setting

Description

 

2400, 4800, 9600, ‹19200

Sets the data speed.

 

 

 

 

English

115