5SCREEN SET

SCREEN SET

1.SEQUENCE SET

2.MASK SET

1. SEQUENCE SET

Use the following procedure to scroll through video from all cameras at a specified interval.

The interval for automatic selection can only be set for full screen and quad display.

1 Click the button on the operation panel.

The “MAIN MENU” is displayed.

2 Click “4. SCREEN SET”.

The “SCREEN SET” screen is displayed.

3 Click “1. SEQUENCE SET”.

The “SEQUENCE SET” screen is displayed.

SEQUENCE SET

4

FULL

:

1S

5

QUAD

:

1S

6

 

 

SAVE

 

4 Set “FULL” to the desired full-screen display interval.

[Settings] (‹ indicates default setting)

 

Setting

Description

 

 

 

 

‹1S

Display changes at a 1 second interval.

 

 

 

 

 

2S - 30S

Display changes at a 2 to 30 second interval.

 

 

 

 

 

INDIV.

Set the period for each camera.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

zThe screen changes if “INDIV.” is selected. See “Switching the main monitor and monitor 2 displays at a set time period” (following) for the next operations.

5 Set “QUAD” to the desired quad-screen display interval.

[Settings] (‹ indicates default setting)

Setting

Description

 

 

 

‹1S

 

Display changes at a 1 second interval.

 

 

 

2S

- 30S

Display changes at a 2 to 30 second interval.

 

 

 

6 Click [SAVE].

The setting is saved.

Switching the main monitor and monitor 2 displays at a set time period

1 Set “FULL” to “INDIV.” on the “SEQUENCE SET” screen.

SEQUENCE SET

1

FULL

: INDIV.

 

2

QUAD

: 1S

3MAIN/MON.2 MONITOR SET

 

TIME PERIOD

: T1 ( 00:00 - 00:00 )

 

 

 

 

 

4

CH

01

02

03

04

05

06

07

08

MAIN MONITOR 1S

1S

1S

1S

1S

1S

1S

1S

5

MON.2

1S

1S

1S

1S

1S

1S

1S

1S

CH

09

10

11

12

13

14

15

16

MAIN MONITOR 1S

1S

1S

1S

1S

1S

1S

1S

MON.2

1S

1S

1S

1S

1S

1S

1S

1S

6

 

 

SAVE

 

2 Set “QUAD” to the desired quad-screen display interval.

3 Set “TIME PERIOD” to the desired time period.

[Settings] (‹ indicates default setting)

Setting

Description

 

 

‹T1

Time period T1

 

 

T2

Time period T2

 

 

T3

Time period T3

 

 

T4

Time period T4

 

 

4 Select the switching interval for each camera on the main monitor.

On the DSR-5009P, cameras No. 01-09 are displayed.

5 Select the switching interval for each camera on monitor 2.

On the DSR-5009P, cameras No. 01-09 are displayed.

6 Click [SAVE].

The setting is saved.

zThe time period for “T1” through “T4” changes to that of “TIME PERIOD A” or “TIME PERIOD B” on the <TIME PERIOD SET> screen (JP.69).

NETWORK SETTINGS

196

English

Page 197