2RECORD SET

7 Turn the jog dial to select the mode value and then turn the shuttle dial clockwise.

When “AUTO ALARM COPY” is selected, the <WARNING> screen is displayed.

 

<WARNING>

 

REC RATE SETTING IN THE MENU WILL BE

 

AUTOMATICALLY ADJUSTED.

 

ARCHIVE AREA INITIALIZE!

 

ARE YOU SURE ?

 

NO

 

CHANGE:JOG SET:SHUTTLE

[Settings] (‹ indicates default setting)

 

 

Setting

Description

‹MANUAL COPY

Manually copy recording images (JP.50).

 

 

AUTO ALARM

Automatically copy alarm recordings to the

COPY

archive area.

 

 

When “AUTO ALARM COPY” is changed to “MANUAL COPY” the following <WARNING> screen is displayed.

<WARNING>

AREA FULL RESET

ARCHIVE AREA

ARE YOU SURE ?

NO

MOVE:JOG SELECT:SHUTTLE

If “MANUAL COPY” is unchanged, the cursor moves to “REMAINING DISK WARNING”. Proceed to step 9.

8 To initialize, select “YES” with the jog dial and turn the shuttle dial clockwise.

To not initialize, select “NO” and turn the shuttle dial clockwise.

9 Turn the shuttle dial clockwise.

“1%” flashes.

<RECORDING CONDITIONS SET>

RECORDING AREA

 

OVERWRITE

: ON

ARCHIVE AREA

 

MODE

: MANUAL COPY

REMAINING DISK WARNING

: 1 %

AUTO DELETE

: OFF

10 Turn the jog dial to select the “REMAINING DISK WARNING” setting and then turn the shuttle dial clockwise.

The remaining capacity can be set anywhere between 1% (default setting) and 10%.

<RECORDING CONDITIONS SET>

RECORDING AREA

 

 

OVERWRITE

: ON

ARCHIVE AREA

 

 

MODE

: MANUAL COPY

REMAINING DISK WARNING

: 1 %

 

 

 

AUTO DELETE

: OFF

 

11 Press the [EXIT/OSD] button.

The setting is completed and the display returns to the normal screen.

EXIT/OSD

The FULL indicator flashes when the remaining capacity for the recording areas reaches the specified percentage value. When the FULL indicator flashes or the recording areas become full, use overwrite permission. (JP.79)

FULL indicator

Remaining

Operation displaycapacity display

01-01-05 00:00:00 REC 5% EN A ALARM 0000000

02

English

81

Page 82
Image 82
Sanyo DSR-5009P instruction manual 01-01-05 000000 REC 5% EN a Alarm, ‹MANUAL Copy, Auto Alarm