3RECORD SET

6. ALARM REC MODE SET

Use the following procedure to set the recording conditions for alarm recording.

Setting alarm recording

Set the operation patterns and recording conditions to perform alarm recording.

1 Click the button on the operation panel.

The “MAIN MENU” is displayed.

2 Click “2. RECORD SET”.

The “RECORD SET” screen is displayed.

3 Click “6. ALARM REC MODE SET”.

The “ALARM REC MODE SET” screen is displayed.

ALARM REC MODE SET

4

ALARM RECORDING

: OFF

 

5

PICTURE QUALITY

: ENHANCED

 

6

AUDIO RECORDING

: OFF

 

7

ALARM INTERLEAVE

: ONLY

 

8

REC RATE : A 12.5 FPS

, DURATION: 20 SEC

9

10

PRE-ALARM RECORDING

: ***

12

11

REC RATE : A 12.5 FPS

, DURATION: 5 SEC

13

=>(813 ALARMS CAN BE RECORDED)

 

ALARM TRIGGER

: ALARM

 

14

 

 

SAVE

 

 

 

 

4 Set “ALARM RECORDING” to the desired recording mode.

[Settings] (‹ indicates default setting)

Setting

Description

 

 

‹OFF

Alarm recording is disabled.

 

 

 

Alarm recording is always

ENABLED

performed regardless of timer

 

recording or timer settings.

 

 

AL-REC ON TIMER

Alarm recording is performed only

during timer recording.

 

 

 

 

Alarm recording is performed only

AL-REC OFF TIMER

during recording other than timer

 

recording.

 

 

 

Alarm recording is performed only in

OLY AL-RC ON TMR

the period set for timer recording

without timer recording actually

 

 

being performed.

 

 

Setting the picture quality for recording

Use the following procedure to set the picture quality for alarm recording.

5 Set “PICTURE QUALITY”.

[Settings] (‹ indicates default setting)

Setting

Description

 

 

BASIC

Basic

 

 

NORMAL

Normal

 

 

‹ENHANCED

Enhanced

 

 

FINE

Fine

 

 

SUPER FINE

Super Fine

 

 

INDIV.

Picture quality is set for each camera.

 

 

„Setting the picture quality for each camera

(1)Set “PICTURE QUALITY” to “INDIV.”.

The “ALARM REC MODE SET” screen is displayed.

ALARM REC MODE SET

 

ALARM RECORDING

 

: ENABLED

 

 

(1)

PICTURE QUALITY

 

 

: INDIV.

 

 

 

(2)

01

02

03

04

05

06

07

08

EN

EN

EN

EN

EN

EN

EN

EN

 

 

09

10

11

12

13

14

15

16

 

EN

EN

EN

EN

EN

EN

EN

EN

(3)

AUDIO RECORDING

 

: OFF

 

 

 

 

ALARM INTERLEAVE

 

: ONLY

 

 

 

 

REC RATE : A 12.5 FPS

, DURATION: 20 SEC

 

 

PRE-ALARM RECORDING

 

: ***

 

 

 

REC RATE : A 12.5 FPS

, DURATION: 5 SEC

=>(981 ALARMS CAN BE RECORDED)

ALARM TRIGGER

: ALARM

(4)

 

 

SAVE

 

(2)Set the picture quality for each camera.

(3)Set “AUDIO RECORDING”, “ALARM INTERLEAVE”, “REC RATE”, “DURATION”, “PRE-ALARM RECORDING”, “REC RATE”, “DURATION” and “ALARM TRIGGER” (Jsteps 6 to 13).

(4)Click [SAVE].

NETWORK

SETTINGS

186

English

Page 187
Image 187
Sanyo DSR-5009P instruction manual 186, Record SET Alarm REC Mode SET, Click 6. Alarm REC Mode SET, Setting alarm recording