Sanyo DSR-5009P instruction manual Recording, Alarm recording, Pre-alarm recording

Models: DSR-5009P

1 227
Download 227 pages 8.71 Kb
Page 31
Image 31

3RECORDING

FULL indicator

Alarm recording

Use the following procedure to record alarm video when an alarm signal is detected.

1 Set alarm recording. (JP.93)

2 When an alarm signal is detected

zWhen an alarm signal is detected, “ALARM” flashes in the operation display and alarm recording starts (indicated by “REC”.)

zWhenever an alarm occurs, the number of alarms indicated in the operation display is incremented.

01-01-05 00:00:00 REC REPEAT EN A ALARM 0000001

Counts the number of

 

alarms.

 

Displays up to

 

9999999.

 

After 9999999, the

 

counter returns to

 

0000000 and

 

resumes counting

02

from 1.

zIf an alarm occurs during normal recording or timer recording, recording ends.

zA maximum of 1,000,000 alarm recordings can be made on one hard disk. The number of maximum recordings can be increased to 6,000,000 by expanding the optional hard disk. However, the maximum number of recordings is affected by set recording conditions. Be sure to check the menu settings and display content.

3 End alarm recording.

When the alarm duration has expired (default setting: 20 seconds), both “REC” and “ALARM” stop flashing on the operation display and recording stops.

zBe sure to set the time when using the digital video recorder for the first time. Recording is not possible until the time is set. (JP.20)

zWhen alarm recording total exceeds 1,000,000 and “OVERWRITE” on the <RECORDING CONDITIONS SET> screen (JP.80) is set to “ON”, older recordings are overwritten even if the hard disk has remaining memory capacity.

Alarm recording is not performed when “OFF” is set.

zWhen “OVERWRITE” on the <RECORDING CONDITIONS SET> screen is set to “OFF” and the space remaining in the recording area becomes insufficient, the FULL indicator begins to flash. If recording is continued beyond this point, the recording area becomes full and recording stops. Perform AREA FULL RESET to enable recording. (JP.79)

Pre-alarm recording

Use the following procedure to record video immediately before the occurrence of an alarm.

1 Set pre-alarm recording. (JP.96)

“PRE” appears in the operation display. Pre-alarm recording starts (without the “REC” symbol being displayed).

2 If an alarm is detected

Pre-alarm recording is automatically ended and alarm recording starts.

z“PRE” disappears from the operation display and “ALARM” begins to flash.

01-01-05 00:00:00 REC REPEAT EN A ALARM 0000001

02

zWhen recording for the first time, the default settings are used. The image quality and recording rate can be changed. (JP.97)

zWhen “OVERWRITE” on the <RECORDING CONDITIONS SET> screen is set to “OFF” and the space remaining in the recording area becomes insufficient, the FULL indicator begins to flash. If recording is continued beyond this point, the recording area becomes full and recording stops. Perform AREA FULL RESET to enable recording. (JP.79)

OPERATION

30

English

Page 31
Image 31
Sanyo DSR-5009P instruction manual Recording, Alarm recording, Pre-alarm recording