1INITIAL SET

Timer period settings

Example 1: Setting periods using TIME PERIOD A and

TIME PERIOD B

4 Turn the jog dial to select “TIME PERIOD A” and then turn the shuttle dial clockwise.

“00:” for T-1 flashes (indicating the hour).

zTIME PERIOD A T-1=6:00T-2=11:30T-3=13:30T-4=18:00

zTIME PERIOD B T-1=6:00T-2=8:00T-3=14:30T-4=20:00

 

<TIME PERIOD SET>

 

 

TIME PERIOD

T-1

T-2

T-3

T-4

 

TIME PERIOD A

00:00

00:00

00:00

00:00

 

TIME PERIOD B

00:00

00:00

00:00

00:00

SELECT TIME PERIOD

 

 

 

 

SEQUENCE

 

TIME PERIOD A

 

 

MASK

 

TIME PERIOD A

 

 

MOTION/ROI SENSOR

TIME PERIOD A

 

<TIME PERIOD SET>

[KEY]

TIME PERIOD

T-1

T-2

T-3

T-4

TIME PERIOD A

00:00

00:00

00:00

00:00

TIME PERIOD B

00:00

00:00

00:00

00:00

SELECT TIME PERIOD

5 Set the time for T-1.

(1) Turn the jog dial to select “06” and then turn the shuttle

dial clockwise.

1 Press the [MENU] button.

The MENU indicator lights up and the <MAIN MENU> is displayed.

MENU

2 Turn the jog dial to select “1.INITIAL SET” and then turn the shuttle dial clockwise.

The <INITIAL SET> screen is displayed.

3 Turn the jog dial to select “5.TIME PERIOD SET” and then turn the shuttle dial clockwise.

The <TIME PERIOD SET> screen is displayed.

 

<TIME PERIOD SET>

 

TIME PERIOD

T-1

T-2

T-3

T-4

 

 

 

 

 

 

 

TIME PERIOD A

00:00

00:00

00:00

00:00

 

TIME PERIOD B

00:00

00:00

00:00

00:00

SELECT TIME PERIOD

 

 

 

 

SEQUENCE

 

TIME PERIOD A

 

 

MASK

 

TIME PERIOD A

 

 

MOTION/ROI SENSOR

TIME PERIOD A

 

For both TIME PERIOD A and TIME PERIOD B, all settings are “00:00” by default setting.

“:00” for T-1 flashes (indicating the minutes).

(2) Turn the shuttle dial clockwise.

“00:” for T-2 flashes (indicating the hour).

6 Set the time for T-2.

(1)Turn the jog dial to select “11” and then turn the shuttle dial clockwise.

“:00” for T-2 flashes (indicating the minutes).

<TIME PERIOD SET>

[KEY]

TIME PERIOD

T-1

T-2

T-3

T-4

TIME PERIOD A

06:00

11:00

00:00

00:00

TIME PERIOD B

00:00

00:00

00:00

00:00

(2)Turn the jog dial to select “30” and then turn the shuttle dial clockwise.

“00:” for T-3 flashes (indicating the hour).

7 Use the same procedure to set the hour and minutes for T-3 and T-4.

8 Use the same procedure to set the hour and minutes for T-1 to T-4 in TIME PERIOD B.

zSettings for T-1 through T-4 cannot be made in such a way that they extend over two days (i.e., include midnight). If “00:00” (midnight) must be set, this should be done using T-1.

Any setting of “00:00” for T-2 through T-4 is skipped.

Example: T-1

T-2

T-3

T-4

06:00

12:00

18:00

00:00

In the above example, T-4 (00:00) is skipped and T-3 operates between 18:00 and 06:00.

zFurthermore, when T-1 through T-4 are all set to “00:00”, all but T-1 are ignored and T-1 operates from midnight to midnight the next day.

English