VIDEO CONVERT

ANALOG VIDEO CONVERSION

The SR7001 is equipped to convert video signals for monitor output. Because of this, indifferent of the connection (VIDEO, S-VIDEO, COMPONENT VIDEO) between the playback device and the SR7001, listening and viewing are possible with a single higher grade cable between the MONITOR OUT terminal of the SR7001 and the monitor.

CONNECTION EXAMPLE

When a monitor is connected to the HDMI MONITOR OUT terminal of the SR7001

VIDEO

 

or S-VIDEO

 

or component

 

or HDMI

HDMI

When a monitor is connected to the COMPONENT

TEMPORARILY TURNING OFF THE SOUND

ENGLISH

VIDEO MONITOR OUT terminal of the SR7001

 

 

 

 

 

 

 

 

 

 

OK

 

 

VIDEO

 

PREV

LIP.SYNC

MUTE

 

or S-VIDEO

component

 

 

MENU

GUIDE

EXIT

 

or component

 

1

2

3

 

 

 

TEST

CH.SEL

SURR

 

 

 

7.1CH

ATT

SPK-AB

 

HDMI

 

4

5

6

 

 

DISP

OSD

SLEEP

 

 

 

7

8

9

 

UP-CONVERSION FROM ANALOG VIDEO

SIGNALS TO HDMI

The up-conversion feature of the SR7001 can output the input analog video signals (for component video signals of 480i/576i, 480p/576P, 1080i and 720p resolution, and S-Video and Video (composite) of 480i/576i resolution) to the HDMI MONITOR terminal.

Notes:

• HDMI video input is only output to the HDMI

MONITOR OUT terminal of the SR7001. If

connecting a playback device such as a DVD

player to the HDMI input jack, connect the HDMI

MONITOR OUT terminal of the SR7001 to a TV

monitor.

• This mode is unavailable for the REC out terminal.

Notes:

If the resolution of the component video signal input from the playback device is other than 480i/576i, 480p/576P, 1080i or 720p, images are not output from the HDMI MONITOR OUT terminal of the SR8001.

If the resolution of the S-Video or Video signal input from the playback device is other than 480i/576i, images are not output from the HDMI MONITOR OUT terminal of the SR7001.

When a monitor is connected to the VIDEO or S- VIDEO MONITOR OUT terminals of the SR7001

Notes:

The HDMI video signal input from the playback device is not output from the COMPONENT VIDEO MONITOR OUT terminal of the SR7001.

Notes of OSD menu system:

The setup menu can be displayed through all video out terminals (“HDMI”, “COMPONENT”, “SVIDEO” and “VIDEO”).

OSD information is output only to the VIDEO and S-VIDEO MONITOR OUT terminals.

OSD information is also output when the video conversion feature is on and the video signal input to the VIDEO or S-VIDEO input jack of the SR7001 is converted and output from the COMPONENT VIDEO or HDMI MONITOR OUT terminals.

To temporarily silence all speaker outputs such as when interrupted by a phone call, press the MUTE button on the remote.

This will interrupt the output to all speakers and the head-phone jack, but it will not affect any recording or dubbing that may be in progress.

When the system is muted, the display will show “MUTE” .

Press the MUTE button again to return to normal operation.

USING THE SLEEP TIMER

 

LIP.SYNC

 

PREV

 

MUTE

 

GUIDE

 

MENU

 

EXIT

TEST

CH.SEL

SURR

1

2

3

• This mode is unavailable for still picture, fast

forward and reverse play on video component.

• If, while attempting to use the video convert feature,

the SR7001 cannot synchronize with the display

device, “NO SIGNAL” appears on the monitor or

noise is generated, this feature cannot be used. All of

these signs are caused by equipment incompatibility;

there is nothing wrong with the SR7001.

If this occurs, set “VIDEO CONVERT” in the

VIDEO

or S-VIDEO

or component

HDMI

VIDEO

or S-VIDEO

I/P CONVERT

The video circuit of the SR7001 is equipped with an I/P conversion feature.

When this feature is on, 480i/576i analog video signals (VIDEO, S-VIDEO or COMPONENT VIDEO) input from a playback device can be converted

7.1CH

ATT

SPK-AB

4

5

6

DISP

OSD

SLEEP

7

8

9

 

THX

 

CLEAR

0

MEMO

VIDEO SETUP” menu to “DISABLE”. Next,

connect the video input signal to the display component

via the MONITOR OUT terminal under VIDEO and

the S-video input signal to the display component via

the MONITOR OUT terminal under S-VIDEO.

• The video convert feature constantly monitors

input video signals and determines whether to

convert the input signals or not. However, some

input video signals cannot be detected correctly.

If this occurs, set “VIDEO CONVERT” in the

VIDEO SETUP” menu to “DISABLE”.

• For optimal video performance, THX recommends

setting the “VIDEO CONVERT” mode “DISABLE”.

Notes:

The HDMI video signal input from the playback device is not output from the VIDEO or S-VIDEO MONITOR OUT terminals of the SR7001.

If the resolution of the component video signal input from the playback device is other than 480i/576i, it is not output from the VIDEO or S-VIDEO MONITOR OUT terminals of the SR7001.

to 480p/576p and progressively output to the COMPONENT VIDEO or HDMI MONITOR OUT terminals of the SR7001.

(For setting instructions, see page 35)

To program the SR7001 for automatic standby, press the SLEEP button on the remote.

Each press of the button will increase the time before shut down in the following sequence.

OFF 10 20 30 40

90 80 70 60 50

The sleep time will be shown for a few seconds in the display on the front panel, and it will count down until the time has elapsed.

When the programmed sleep time has elapsed, the unit will automatically turn off.

Note that the SLEEP indicator on the display will illuminate when the Sleep function is programmed. To cancel the Sleep function, press the SLEEP button until the display shows “SLEEP OFF” and the SLEEP indicator will disappear.