3RECORD SET

AREA FULL RESET

If “OVERWRITE” is set to “OFF” for recording conditions, recording automatically stops when the recording areas become full. In this case, AREA FULL RESET can be used to overwrite previous recordings.

4 Click [AREA FULL RESET] under

“RECORDING AREA”.

To perform AREA FULL RESET for the archive area, click [AREA FULL RESET] under “ARCHIVE AREA”.

zWhen AREA FULL RESET is performed for “RECORDING AREA”, the recordings in the recording area are overwritten.

zWhen AREA FULL RESET is performed for “ARCHIVE AREA”, the recordings in the archive area are overwritten.

2. RECORDING CONDITIONS SET

Use the following procedure to set the permission for overwriting to recording areas or the remaining-space warning level.

Setting overwriting permission for recording areas

When the recording areas become full, this setting dictates whether recording stops or continues by overwriting the recorded images currently stored on the hard disk.

1 Click the button on the operation panel.

The “MAIN MENU” is displayed.

2 Click “2. RECORD SET”.

The “RECORD SET” screen is displayed.

3 Click “2. RECORDING CONDITIONS SET”.

The “RECORDING CONDITIONS SET” screen is displayed.

RECORDING CONDITIONS SET

4

 

 

RECORDING AREA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OVERWRITE

:

 

ON

 

 

 

 

 

 

ARCHIVE AREA

 

 

 

 

 

 

 

 

 

MODE

: MANUAL COPY

5

 

 

REMAINING DISK WARNING

:

 

 

%

 

 

 

 

 

1

 

 

6

 

 

AUTO DELETE

:

 

 

 

 

7

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SAVE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 Set “OVERWRITE” for the “RECORDING AREA” to “ON” or “OFF”.

[Settings] (‹ indicates default setting)

Setting

Description

OFF

Recording stops when a recording area becomes

full.

 

 

 

 

When a recording area becomes full, overwriting

‹ON

from the beginning of this area starts

 

automatically.

 

 

Setting the remaining-space warning level

When the overwrite setting for a recording area is “OFF”, the unit can issue a warning as soon as the remaining space reaches a specific level. (JP.189)

Use the following procedure to set the level at which the warning is issued.

5 Set “REMAINING DISK WARNING” to the desired remaining-space warning level.

[Settings] (‹ indicates default setting)

Setting

Description

‹1 - 10

Remaining-space warning level can be set from

1% to 10%.

 

 

 

Setting AUTO DELETE

Use the following procedure to set the storage period for recorded data. When the set period expires, the corresponding data is automatically deleted.

6 Set “AUTO DELETE” to the desired storage period.

[Settings] (‹ indicates default setting)

Setting

Description

 

 

‹OFF

Auto delete is disabled.

 

 

1 - 99

Set the storage period for recorded data from “1

DAYS

DAY” to “99 DAYS” (full days).

 

 

7 Click [SAVE].

The setting is saved.

NETWORK SETTINGS

 

182

English

Page 183
Image 183
Sanyo DSR-5009P instruction manual 182, Recording Conditions SET