Sanyo DSR-5009P Setting program recording, Example P-1, Program, Select Individual Camera Rate

Models: DSR-5009P

1 227
Download 227 pages 8.71 Kb
Page 86
Image 86

2RECORD SET

zWhen only one camera is connected, recording is performed at 25 FPS even if 50 or 100 FPS is set.

zWhen four cameras are connected and 100 FPS is set, recording is performed at the recording rate close to the set rate (100 FPS) divided by the number of cameras. (Example: When 8 cameras are connected and the recording rate setting is 100 FPS, the actual recording rate is 12.5 FPS)

10 Turn the shuttle dial clockwise.

“OFF” flashes.

<NORMAL REC MODE SET>

PICTURE QUALITY

: ENHANCED

PICTURE QUALITY SET

->

AUDIO RECORDING

: ON

REC RATE : A 12.5 FPS ( 156H)

REC PROGRAM GROUP

: OFF

11 Turn the jog dial to select the “REC PROGRAM GROUP” number and then turn the shuttle dial clockwise.

Example: P-1

 

<NORMAL REC MODE SET>

 

PICTURE QUALITY

: ENHANCED

 

PICTURE QUALITY SET

->

 

AUDIO RECORDING

: ON

 

REC RATE : ***** FPS ( 0H)

 

REC PROGRAM GROUP

: P-1

[Settings] (‹ indicates default setting)

 

 

 

 

Setting

Description

 

‹OFF

Video from all cameras is recorded at the

same rate.

 

 

 

 

 

P-1

Used when recording with Program No. 1.

 

 

P-2

Used when recording with Program No. 2.

 

 

P-3

Used when recording with Program No. 3.

 

 

P-4

Used when recording with Program No. 4.

 

 

 

12 Press the [EXIT/OSD] button.

The setting is completed and the display returns to the normal screen.

EXIT/OSD

Setting program recording

Use the following procedure to program the camera numbers for recording. Four programs can be set. For example, Program No. 1 could be setup to record from cameras No. 1 through No. 4 only, whereas Program No. 2 could be setup to record from cameras No. 3 through No. 6. In addition, these programs can also be used for timer recording.

zEven if audio recording is set to “ON” using the <NORMAL REC MODE SET> screen, certain settings for program recording may make audio recording impossible. Set more than one of the 16 channels to 1 FPS or greater to record audio.

On the DSR-5009P, set more than one of the nine channels.

<PROGRAM REC SET>

(1)PROGRAM : P-1

(2)

 

SELECT INDIVIDUAL CAMERA RATE (FPS)

 

01:1

02:1

03:1

04:1

 

 

05:1

06:1

07:1

08:1

 

09:1

10:1

11:1

12:1

 

13:1

14:1

15:1

16:1

NORMAL REC : 57H

(1) PROGRAM

Selects Program No. 1 through Program No. 4.

(2) SELECT INDIVIDUAL CAMERA RATE

Sets which of the connected cameras to record from. Recording rates can also be set for each camera.

Example: Setting Program No. 1 to record video only from cameras No. 1 through No. 3 at a recording rate of 5

1 Press the [MENU] button.

The MENU indicator lights up and the <MAIN MENU> is displayed.

MENU

2 Turn the jog dial to select “2.RECORD SET” and then turn the shuttle dial clockwise.

The <RECORD SET> screen is displayed.

English

85

Page 86
Image 86
Sanyo DSR-5009P instruction manual Setting program recording, Example P-1, Program, Select Individual Camera Rate