8ADVANCED MENU SET

Setting ROI

Set the Region of Interest (ROI) to enable recording at different picture qualities, only of areas preset on the monitor. Enables recording at high picture qualities for areas where motion is detected.

This function allows you to raise the quality level for the preset ROI or lower the quality level for unnecessary areas without changing the image size each time.

Setting the ROI

There are three static areas in the ROI. The static areas are fixed and preset.

Perform the following settings.

zQUALITY: Set for each of the three static areas in the ROI.

zACTIVE ROI: Set each of the three static areas to always activate or activate only when motion is detected.

zEFFECTIVE MODE: Set to perform normal recording or alarm recording.

zAREA/SENSITIVITY: Set delay for time period, sensitivity, and triggering finish.

zRefer to “Setting ROI areas” (JP.142) for static area settings.

zIf ROI settings overlap, the settings from the previous row are prioritized.

1 Press the [MENU] button.

The MENU indicator lights up and the <MAIN MENU> is displayed.

MENU

2 Turn the jog dial to select “8.ADVANCED MENU SET” and then turn the shuttle dial clockwise.

The <ADVANCED MENU SET> screen is displayed.

3 Turn the jog dial to select “1.ROI SET” and then turn the shuttle dial clockwise.

The <ROI SET> screen is displayed.

 

 

 

<ROI SET>

 

CH-01

 

 

QUALITY

ACTIVE ROI

STATIC AREA 1

:

OFF

OFF

STATIC AREA 2

:

OFF

OFF

STATIC AREA 3

:

OFF

OFF

EFFECTIVE REC MODE : NORMAL REC

AREA/SENSITIVITY SET ---->

4 Turn the shuttle dial clockwise.

The camera number flashes.

 

 

<ROI SET>

 

CH-01

 

QUALITY

ACTIVE ROI

STATIC AREA 1

:

OFF

OFF

STATIC AREA 2

:

OFF

OFF

STATIC AREA 3

:

OFF

OFF

EFFECTIVE REC MODE : NORMAL REC

AREA/SENSITIVITY SET ---->

5 Turn the jog dial to select the camera number for the camera to set ROI for and turn the shuttle dial clockwise.

The cursor moves to “QUALITY” and “ACTIVE ROI” in “STATIC AREA 1”.

6 Turn the shuttle dial clockwise.

“OFF” flashes for “QUALITY” in “STATIC AREA 1”.

 

 

<ROI SET>

 

CH-01

 

QUALITY

ACTIVE ROI

STATIC AREA 1

:

OFF

OFF

STATIC AREA 2

:

OFF

OFF

STATIC AREA 3

:

OFF

OFF

EFFECTIVE REC MODE : NORMAL REC

AREA/SENSITIVITY SET ---->