Sanyo DSR-5009P instruction manual 146

Models: DSR-5009P

1 227
Download 227 pages 8.71 Kb
Page 147
Image 147

8ADVANCED MENU SET

7 When “2ND RS485/422” is selected for “PROTOCOL”, turn the jog dial to select “2ND RS485/422 PROTOCOL”, and turn the shuttle clockwise.

 

<CAMERA CONTROL SET>

 

CH PROTOCOL

ADD

CH PROTOCOL

ADD

01

SANYO COAX1

001

09

OFF

---

02

BBV COAX

---

10

OFF

---

03

PELCO COAX

---

11

OFF

---

04

2ND RS-485/422

004

12

OFF

---

05

OFF

---

13

OFF

---

06

OFF

---

14

OFF

---

07

OFF

---

15

OFF

---

08

OFF

---

16

OFF

---

2ND RS485/422 PROTOCOL : OFF

8 Turn the jog dial to select the protocol to set and then turn the shuttle dial clockwise.

 

 

<CAMERA CONTROL SET>

 

CH PROTOCOL

ADD

CH PROTOCOL

ADD

01

 

SANYO COAX1

001

09

OFF

---

02

BBV COAX

---

10

OFF

---

03

PELCO COAX

---

11

OFF

---

04

2ND RS-485/422

004

12

OFF

---

05

OFF

---

13

OFF

---

06

OFF

---

14

OFF

---

07

OFF

---

15

OFF

---

08

OFF

---

16

OFF

---

2ND RS485/422 PROTOCOL : BBV

zDATA SPEED for protocol set in “2ND RS485/422 PROTOCOL” is fixed.

Set the DATA SPEED on the camera in the following manner.

z PELCO: 2,400 bps

z KALATEL: 4,800 bps

z SENSORMATIC: 4,800 bps

z BBV: 9,600 bps

9 Press the [EXIT/OSD] button.

The setting is completed and the display returns to the normal screen.

EXIT/OSD

zCamera control address

The camera address is a fixed value and is as follows.

If a protocol other than SANYO COAX1, SANYO RS-485 or 2ND RS485/RS422 is selected, “---” is displayed for the cameral control address.

On the DSR-5009P, CH1-CH9 are available.

DVR/

Camera control

DVR/

Camera control

 

 

RS-485

RS-485

 

 

address

address

 

 

address

address

 

 

 

 

 

 

 

 

DVR1:001

CH1

001

DVR2:002

CH1

017

 

 

 

 

 

 

 

 

 

 

 

CH2

002

 

CH2

018

 

 

 

 

 

 

 

 

 

 

 

CH3

003

 

CH3

019

 

 

 

 

 

 

 

 

 

 

 

CH4

004

 

CH4

020

 

 

 

 

 

 

 

 

 

 

 

CH5

005

 

CH5

021

 

 

 

 

 

 

 

 

 

 

 

CH6

006

 

 

 

 

 

 

 

 

 

 

 

CH7

007

 

 

 

 

SETTINGS

 

 

 

 

 

 

 

 

CH8

008

 

 

 

 

 

 

 

 

 

 

 

 

 

CH9

009

DVR8:008

CH1

113

 

 

 

 

 

 

 

 

 

 

 

CH10

010

 

CH2

114

 

 

 

 

 

 

 

 

 

 

 

CH11

011

 

CH3

115

 

 

 

 

 

 

 

 

 

 

 

CH12

012

 

CH4

116

 

 

 

 

 

 

 

 

 

 

 

CH13

013

 

CH5

117

 

 

 

 

 

 

 

 

 

 

 

CH14

014

 

 

 

 

 

 

 

 

 

 

 

CH15

015

 

CH15

127

 

 

 

 

 

 

 

 

 

 

 

CH16

016

 

CH16

000*1

 

 

*1 Cannot be operated from a VSP-9000 controller.