3RECORD SET

RECORD SET

1.RECORDING AREA SET

2.RECORDING CONDITIONS SET

3.NORMAL REC MODE SET

4.PROGRAM REC SET

5.TIMER SET

6.ALARM REC MODE SET

1. RECORDING AREA SET

The unit’s hard disk is separated into two independent recording areas. Furthermore, five different recording modes can be used for these two areas.

The memory capacity for each area is allocated as a percentage. (Setting units: 1%)

Recording

Recording

Recording method

area

mode

 

 

 

Normal

 

Recording is performed by

 

Manual

manual operation of the

 

recording

 

 

 

button on the operation panel.

 

 

 

Recording is performed

 

Timer

Automatic

automatically for the time

 

recording

period set with “2-5. TIMER

 

 

 

SET”.

 

 

 

 

 

Recording

 

 

Recording is performed

Alarm

Automatic

automatically when an alarm

area

recording

is detected, as set with “2-6.

 

 

 

ALARM REC MODE SET”.

 

 

 

 

 

 

 

Automatic recording of images

 

 

 

before an alarm occurs, as set

 

Pre-alarm

Automatic

with “PRE-ALARM RECORDING”

 

in “2-6. ALARM REC MODE

 

recording

 

 

 

SET”.

 

 

 

 

This function is used together

 

 

 

with alarm recording.

 

 

 

The required images are

Archive

 

 

copied from another recording

Copy

Manual

area and stored by manual

area

 

 

operation of the

button on

 

 

 

 

 

 

the operation panel.

 

 

 

 

 

 

1 Click the button on the operation panel.

The “MAIN MENU” is displayed.

2 Click “2. RECORD SET”.

The “RECORD SET” screen is displayed.

3 Click “1. RECORDING AREA SET”.

The “RECORDING AREA SET” screen is displayed.

RECORDING AREA SET

(1)

 

TOTAL CAPACITY

: 600 GB

 

 

 

INTERNAL HDD

: 300 GB

 

 

EXTERNAL HDD

: 300 GB

 

 

 

 

(2)

RECORDING AREA

: 80%

 

 

 

AREA FULL RESET

 

 

ARCHIVE AREA

: 20%

 

AREA FULL RESET

 

 

 

(3)

(1) Total capacity display

Displays the total capacity of the hard disk and the capacity of all internal and expansion hard disks.

zA maximum of six hard disks can be installed.

(2) Area-specific capacity display

Displays the capacity set by the unit for each recording area as a percentage of the total capacity.

zSetting and modification of recording area capacities cannot be made from a PC.

(3) Recording area reset

If the overwrite setting is “OFF”, recording automatically stops when the corresponding recording area becomes full. In this case, click [AREA FULL RESET] to overwrite from the beginning of each area. (Jstep 4)

Reset is not required in the following cases and, therefore, [AREA FULL RESET] is not displayed.

zWhen the overwrite setting is “ON”.

English

181

Page 182
Image 182
Sanyo DSR-5009P instruction manual 181, Click 2. Record SET, Click 1. Recording Area SET