Sanyo DSR-5009P 187, Set Audio Recording, Set Alarm Interleave to the desired recording pattern

Models: DSR-5009P

1 227
Download 227 pages 8.71 Kb
Page 188
Image 188

3RECORD SET

Setting audio recording

Audio can be recorded together with images during alarm recording. Note, however, that since this audio data is also stored in the recording area, the recording time for this area decreases.

6 Set “AUDIO RECORDING”.

[Settings] (‹ indicates default setting)

 

Setting

Description

 

 

 

 

 

‹OFF

Audio is not recorded.

 

 

 

 

 

 

ON

Audio is recorded.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

zAudio recording can be enabled when the recording rate is between A50 and A1 FPS.

Setting the alarm interleave

7 Set “ALARM INTERLEAVE” to the desired recording pattern.

[Settings] (‹ indicates default setting)

Setting

Description

 

 

‹ONLY

Video is recorded only from cameras with an alarm

occurring.

 

 

 

 

Recording is switched between video from a

SW

camera for which an alarm has occurred and video

 

from all connected cameras.

 

 

8 Set “REC RATE” to the desired recording rate.

[Settings] (‹ indicates default setting)

Setting

Description

 

 

A50, A25, A16.67, ‹A12.5,

 

A8.333, A6.25, A5, A4.167,

Recording is performed at the

A3.571, A3.125, A2.778,

selected recording rate (unit:

A2.5, A2.273, A1.923,

FPS). (Audio can be recorded.)

A1.667, A1.471, A1.316,

 

A1.19, A1.087, A1

 

 

 

0.5, 0.333, 0.25, 0.2, 0.1,

Recording is performed at the

selected recording rate (unit:

0.05, 0.033

FPS). (Audio cannot be recorded.)

 

 

 

The letter “A” is displayed in front of recording rates that can be set for audio recording.

zWhen only one camera is connected, recording is performed at 25 FPS even if 50 FPS is set.

zWhen two or more cameras are connected and 50 FPS is set, the actual recording rate is roughly the recording rate divided by the number of cameras. (Example: When 4 cameras are connected and the recording rate setting is 50 FPS, the actual recording rate is 12.5 FPS)

9 Set “DURATION” to the desired alarm recording duration.

[Settings] (‹ indicates default setting)

Setting

Description

5SEC, 10SEC, ‹20SEC,

Records for the set duration for

40SEC, 1MIN, 2MIN, 3MIN,

each alarm.

4MIN, 5MIN, 10MIN, 15MIN

 

 

 

 

Records while an alarm is

CC

activated (Recording continues

for five seconds even if less than

 

 

five seconds).

 

 

Setting pre-alarm recording.

Use the following procedure to set the recording conditions to be used for pre-alarm. (JP.162)

10 Set “PRE-ALARM RECORDING” to “ON” or “OFF”.

[Settings] (‹ indicates default setting)

 

Setting

Description

 

 

 

 

‹OFF

Pre-alarm recording is disabled.

 

 

 

 

 

ON

Pre-alarm recording is enabled.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

zIf “ALARM RECORDING” is set to “OFF”, the PRE-ALARM RECORDING setting is displayed as “**” and cannot be set.

11 Set “REC RATE” to the desired recording rate.

[Settings] (‹ indicates default setting)

Setting

Description

 

 

A100, A50, A25, A16.67,

 

‹A12.5, A8.333, A6.25,

Recording is performed at the

A5, A4.167, A3.571,

A3.125, A2.778, A2.5,

selected recording rate (unit:

A2.273, A1.923, A1.667,

FPS).

A1.471, A1.316, A1.19,

 

A1.087, A1

 

 

 

The letter “A” is displayed in front of recording rates that can be set for audio recording.

English

187

Page 188
Image 188
Sanyo DSR-5009P instruction manual 187, Set Audio Recording, Set Alarm Interleave to the desired recording pattern