3INSTALLATION AND CONNECTIONS

Connecting SENSOR ALARM OUT terminals

The SENSOR ALARM OUT terminals are used to relay alarm signals whenever one of the digital video recorder’s motion sensors is triggered. Normally in an open condition, a terminal adopts a low condition when a sensor for the corresponding camera number has been triggered.

1K

 

Rated value of terminals

 

 

z Maximum current: 25 mA

 

 

z Maximum voltage: 25 V

 

 

Connecting control terminals

The connections for a remote control circuit are shown below. This digital video recorder can be remotely controlled when a remote-control circuit similar to that shown here is connected to the remote-input control terminals.

REMOTE

C R1 R2

R1

 

R2

(Whenoperated(When combined

 

independently) with R2 FUNC key)

 

SW 1

:Camera 1:INDEX+

SW 17 :REC/STOP

SW 2

:Camera 2:INDEX-

SW 18 :PLAY/STOP

SW 3

:Camera 3:AUTO FOCUS

SW 19 :STILL

SW 4

:Camera 4 :Automaticselection display

SW 20 :SEARCH

SW 5

:Camera 5:Monitor2

SW 21 :SHIFT (Doubles with R1)

SW 6

:Camera 6:Plus display

SW 22 :PLAY

SW 7

:Camera 7:QUAD

SW 23 :REC

SW 8

:Camera 8:MULTI

SW 24 :MENU

SW 9

:Camera 9:MENU RESET

SW 25 :MENU EXIT(EXIT)

SW 10

:Camera 10:Not used

SW 26 : +

SW 11

:Camera 11:PAN left

SW 27 : -

SW 12

:Camera 12:PAN right

SW 28 : +

SW 13

:Camera 13:TILT down

SW 29 : -

SW 14

:Camera 14:TILT up

SW 30 :ZOOM

SW 15

:Camera 15:ZOOM wide

SW 31 :COPY

SW 16

:Camera 16:ZOOM tele

SW 32 :TIMER

zUse a resistance of 1/10 ohms or more and with a D ranking (Precision within ±0.5%).

zThe remote control cable should be no more than 5 m long. * The DSR-5009P can operate up to nine cameras.

Connecting the power cord

1 After all other connections are made, make sure the voltage is 120 V-240 V AC and then insert the power plug into the wall outlet.

There is no power switch. The display indicators flash, and after a few moments, the monitor screen displays the camera video.

120 V-240 V AC (50/60 Hz)

*

* Attach the core clamp

 

 

(large) to the power cord.

zWhen turning the power on for the first time

“PLEASE SET THE CLOCK” is displayed on the monitor screen. Set the clock. (JP.20)

zIf the clock is already set

The operation display area is displayed.

Operation

01-01-05 00:00:00

EN A

display area

 

 

02

zIf the ERROR indicator starts flashing

The digital video recorder has a self-diagnostic function to find malfunctions. If a malfunction occurs while the power is on, the ERROR indicator flashes in a cycle to indicate the malfunction.

If the ERROR indicator flashes, contact a Sanyo service center.

When flashing at 4Hz (Four times per second):

The hard disk is checked automatically when the power is turned on. The POWER indicator flashing indicates that a malfunction has been found on the hard disk and the hard disk must be replaced or initialized. If you need to save video stored on the disk, contact a Sanyo service center.

When flashing at 1Hz (Once per second): A fan malfunction has occurred.

zThe power cord’s ground terminal is not provided for enhanced safety; rather, it is used to reduce the level of interference when the digital video recorder is connected to analog devices.