EverFocus EFC--02-1-A user manual Enter Extended Alarm Setting Sub-menu, Fire Alarm

Page 58

Alarm output configuration for all events under this menu follows the similar style in the above example.

Note: in the above example all 4 door modules are installed. In case less than 4 door modules are installed, positions corresponding to uninstalled modules are replaced with minus sign ‘-’, as shown below:

Invalid Card

RNNNNNNN-NN

The figure shows the case where 3 door modules are installed. Alarm output status on the main module is stilled configured by pressing numeric key 9,0.

Enter Extended Alarm Setting Sub-menu

Under Alarm Setting menu, press once to bring up the following window:

Extended Alarm

Setting

Press ENT to enter Extended Alarm Setting submenu. The first submenu is for fire

alarm outputs. Use and to choose from different alarm menus for different events. Alarm output configuration for all events is basically the same. As an example, alarm output configuration for invalid card event is introduced below. The figure below shows the menu interface:

Invalid Card

NNNNNNNN

The upper line indicates the card to be configured, i.e., invalid card. The first 8 characters of the lower line are alarm output status of this event on the alarm module. Y indicates there is alarm output (relay energized) and N indicates there is no alarm output (relay not energized).

In the above example, alarm output relays on all alarm modules will not be energized and no alarm outputs will be generated due to the invalid card event.

In this menu, press numeric key 1~8 to toggle the alarm output status of this event on the alarm module between Y and N. Alarm output configuration for all events under this menu follows the similar style in the above example.

In what follows, definitions of all events and configuration methods are introduced.

Fire Alarm

For correspondence between fire alarm and doors, please refer to “connection to fire alarm input” in chapter 4. In case of fire alarm input, controller will generate fire

50

Image 58
Contents Flex Series Controller EFC-02-1A Instruction Guide Table of Contents Chapter Page ARM/DISARM Specifications FederalCommunication Commission Interference Statement Features Product OverviewParts List Controller Layout Controller Layout Main modulePage Installation Review Preparing for the InstallationObtain a Floor Plan Preparing for the InstallationDetermining Hardware and Location Entry Card Readers Hardware Installation Mounting the Enclosure and ControllerStep Installing a Module to Controller Install a New Module to ControllerTerminal / LED Definitions Reader/Door Index ConversionMain Module Terminal Definition Main Module LED Definition Terminal name Function No Terminal nameDoor Module Terminal Definition LED MeaningDoor Module LED Definition Definitions of the Door Module TerminalsAlarm Module Terminal Definition Terminal Function NameInstall and Connecting the Readers Alarm Module LED DefinitionRS232 Format Wiegand 26 FormatConnection to Door Lock Connection to an Electric StrikeConnection to Door Sensor Connection to a Magnetic LockConnection to Alarm Input Connection to Fire & Alarm InputConnection to Request-to-Exit Connection to Alarm Output 14 Connecting Alarm-sensor to Controller16 Normally Closed Connections for Alarm Output Connecting Controller Computer Connection to Computer via RS232Connection to Desktop Reader via RS485 RS485 Bus Based Networking SystemRS485 Bus Extension Connection to Multiple Controllers via RS485 Two Incorrect ConnectionsTCP/IP Based System Connection to Multiple Controllers via RS485Page Connecting Power Connecting the Power SupplyConnection to Backup Battery Mount a Backup Battery optionalReset Controller Cover Placement Before First UsePage Enter System Configuration General Operation GuidelineMain Setting Items Display the Number of Installed ModulesDisplay the Firmware Version Enter System Setting Menu System SettingSet Date Format Auto Daylight Savings Time Set DateSet Time Set Arm PIN Set System PINErase All Events Reset All Data and Settings Card SettingEnter Card Setting Menu Delete Cards Add CardsDelete a Card by Serial Number Set Card Properties Status SettingDelete All Cards Group Setting Access Right SettingSet Card PIN Setting Anti Passback APB Setting Card ARM Setting Reader SettingEnter Reader Setting Menu Show Card NumberKeypad Setting Reader to Door AllocationEnter Door Setting Menu Door SettingSystem Reader Setting Open Time SettingSet Door Behavior at Fire Alarm Set Door Hold Open TimeComponents for Alarm Alarm SettingAlarm Configuration Basics Enter Alarm Setting Menu Alarm Setting Menu StructureEnter Alarm Action Setting Sub-menu Enter Extended Alarm Setting Sub-menu Fire AlarmSYS PIN Fail Zone Alarm 1~8ARM PIN Fail Unknown Card AlarmRemote Alarm Expired CardInvalid Time Invalid CardInvalid Door Card Anti-Passback FailDoor Forced Open Card PIN FailDoor Held Open Enter Armzone Setting Menu Armzone SettingEnter Alarm Time Setting Sub-menu Reader LostSet ARM Delay Time Set Active ArmzoneAddress Setting Arm the System using the Controller KeypadDisarm the System using the Controller Keypad Clear the AlarmArm/Disarm the System using a Reader Yellow LED Status System ARM StatusPage Software Setup Install the Software in the Control ComputerSetup the User Accounts for the Software Configure the Controller and All Other HardwareEnroll Cards Page Page Page EverAccess

EFC--02-1-A specifications

The EverFocus EFC--02-1-A is an advanced video surveillance solution designed to meet the high demands of modern security systems. This device stands out for its robust features, cutting-edge technologies, and exceptional reliability, making it ideal for a wide range of surveillance applications, from retail environments to industrial facilities.

One of the primary features of the EFC--02-1-A is its superior image quality. Equipped with high-definition video capabilities, the camera can capture crystal-clear images even in low-light conditions, thanks to its advanced low-light technology. This ensures that vital details are recorded, enhancing the overall effectiveness of surveillance efforts. The device boasts a wide dynamic range (WDR), which allows it to handle scenes with both bright and dark areas, maintaining image clarity and detail regardless of lighting variations.

The EFC--02-1-A also supports multi-streaming capabilities, enabling simultaneous transmission of multiple video streams in different resolutions. This versatility is particularly advantageous for network bandwidth management, allowing users to customize their surveillance setup according to specific requirements. The integration of advanced compression technologies such as H.265 ensures efficient use of storage while maintaining high video quality.

Durability is another hallmark of the EFC--02-1-A. The camera is designed to withstand harsh environmental conditions, featuring an IP67-rated enclosure that protects it from dust and water ingress. This weatherproof design makes it suitable for both indoor and outdoor installations, ensuring uninterrupted operation in various settings.

Moreover, the EFC--02-1-A comes equipped with smart analytics capabilities, including motion detection and face recognition technologies. These features enhance the system’s functionality by enabling automatic alerts and efficient monitoring of specific areas, thereby reducing the workload for security personnel.

Lastly, seamless integration is a core characteristic of the EFC--02-1-A. It is compatible with multiple video management systems (VMS) and can easily connect with other security devices, promoting a holistic security ecosystem. This interoperability, coupled with user-friendly operational features and remote access capabilities, positions the EverFocus EFC--02-1-A as a leading choice for organizations aiming to enhance their surveillance setups.