EverFocus EFC--02-1-A System Reader Setting, Enter Door Setting Menu, Open Time Setting

Page 53

System Reader Setting

System reader can be used to acquire the card’s serial number when controller configures the card. User can set any reader that connects to the controller as the system reader. At the following submenu:

System Reader

Setting

Press ENT to enter System Reader setting. System will show current status of all readers as shown below. Y means the reader is the system reader, N means it’s not. By default, the first reader is set as the system reader.

12345678 YNNNNNNN

Press any of the 1-8 numeric corresponding readers. Press CLR

keys to change the system reader setting of to exit.

Door Setting

Every door module controls two door relays. EFC-02 controller can control up to 8 doors in total, defined as door 1 to 8 from left to right. According to card reader setting above, users can allocate multiple readers to one single door. User can directly set door open time, door held open time and the door control at fire alarm on the controller.

Enter Door Setting Menu

Under System menu, press three times to bring up the following window:

Door Setting

Press to enter Door Setting menu. Use and to choose from different menu options. All menu options under Door Setting are introduced below:

Open Time Setting

This sets the door open time when the card is swiped or open door button is pushed. The default time is 3 seconds. The maximal door open time supported by the controller is 999 minutes and 59 seconds. The door remains open as long as the open door button is pushed down. The door open time does not count until the button is released. At the following submenu:

Open Time

Setting

45

Image 53
Contents Flex Series Controller EFC-02-1A Instruction Guide Table of Contents Chapter Page ARM/DISARM Specifications FederalCommunication Commission Interference Statement Product Overview FeaturesParts List Controller Layout Main module Controller LayoutPage Preparing for the Installation Installation ReviewDetermining Hardware and Location Preparing for the InstallationObtain a Floor Plan Entry Card Readers Mounting the Enclosure and Controller Hardware InstallationStep Install a New Module to Controller Installing a Module to ControllerMain Module Terminal Definition Reader/Door Index ConversionTerminal / LED Definitions Terminal name Function No Terminal name Main Module LED DefinitionLED Meaning Door Module Terminal DefinitionDefinitions of the Door Module Terminals Door Module LED DefinitionTerminal Function Name Alarm Module Terminal DefinitionAlarm Module LED Definition Install and Connecting the ReadersWiegand 26 Format RS232 FormatConnection to an Electric Strike Connection to Door LockConnection to a Magnetic Lock Connection to Door SensorConnection to Request-to-Exit Connection to Fire & Alarm InputConnection to Alarm Input 14 Connecting Alarm-sensor to Controller Connection to Alarm Output16 Normally Closed Connections for Alarm Output Connection to Computer via RS232 Connecting Controller ComputerRS485 Bus Based Networking System Connection to Desktop Reader via RS485RS485 Bus Extension Two Incorrect Connections Connection to Multiple Controllers via RS485Connection to Multiple Controllers via RS485 TCP/IP Based SystemPage Connecting the Power Supply Connecting PowerReset Controller Mount a Backup Battery optionalConnection to Backup Battery Before First Use Cover PlacementPage General Operation Guideline Enter System ConfigurationDisplay the Firmware Version Display the Number of Installed ModulesMain Setting Items Set Date Format System SettingEnter System Setting Menu Set Time Set DateAuto Daylight Savings Time Erase All Events Set System PINSet Arm PIN Enter Card Setting Menu Card SettingReset All Data and Settings Delete a Card by Serial Number Add CardsDelete Cards Delete All Cards Status SettingSet Card Properties Set Card PIN Setting Access Right SettingGroup Setting Anti Passback APB Setting Enter Reader Setting Menu Reader SettingCard ARM Setting Show Card NumberReader to Door Allocation Keypad SettingSystem Reader Setting Door SettingEnter Door Setting Menu Open Time SettingSet Door Hold Open Time Set Door Behavior at Fire AlarmAlarm Configuration Basics Alarm SettingComponents for Alarm Alarm Setting Menu Structure Enter Alarm Setting MenuEnter Alarm Action Setting Sub-menu Fire Alarm Enter Extended Alarm Setting Sub-menuARM PIN Fail Zone Alarm 1~8SYS PIN Fail Remote Alarm AlarmUnknown Card Expired CardInvalid Door Invalid CardInvalid Time Card Anti-Passback FailDoor Held Open Card PIN FailDoor Forced Open Enter Alarm Time Setting Sub-menu Armzone SettingEnter Armzone Setting Menu Reader LostSet Active Armzone Set ARM Delay TimeArm the System using the Controller Keypad Address SettingClear the Alarm Disarm the System using the Controller KeypadYellow LED Status System ARM Status Arm/Disarm the System using a ReaderPage Install the Software in the Control Computer Software SetupConfigure the Controller and All Other Hardware Setup the User Accounts for the SoftwareEnroll Cards Page Page Page EverAccess

EFC--02-1-A specifications

The EverFocus EFC--02-1-A is an advanced video surveillance solution designed to meet the high demands of modern security systems. This device stands out for its robust features, cutting-edge technologies, and exceptional reliability, making it ideal for a wide range of surveillance applications, from retail environments to industrial facilities.

One of the primary features of the EFC--02-1-A is its superior image quality. Equipped with high-definition video capabilities, the camera can capture crystal-clear images even in low-light conditions, thanks to its advanced low-light technology. This ensures that vital details are recorded, enhancing the overall effectiveness of surveillance efforts. The device boasts a wide dynamic range (WDR), which allows it to handle scenes with both bright and dark areas, maintaining image clarity and detail regardless of lighting variations.

The EFC--02-1-A also supports multi-streaming capabilities, enabling simultaneous transmission of multiple video streams in different resolutions. This versatility is particularly advantageous for network bandwidth management, allowing users to customize their surveillance setup according to specific requirements. The integration of advanced compression technologies such as H.265 ensures efficient use of storage while maintaining high video quality.

Durability is another hallmark of the EFC--02-1-A. The camera is designed to withstand harsh environmental conditions, featuring an IP67-rated enclosure that protects it from dust and water ingress. This weatherproof design makes it suitable for both indoor and outdoor installations, ensuring uninterrupted operation in various settings.

Moreover, the EFC--02-1-A comes equipped with smart analytics capabilities, including motion detection and face recognition technologies. These features enhance the system’s functionality by enabling automatic alerts and efficient monitoring of specific areas, thereby reducing the workload for security personnel.

Lastly, seamless integration is a core characteristic of the EFC--02-1-A. It is compatible with multiple video management systems (VMS) and can easily connect with other security devices, promoting a holistic security ecosystem. This interoperability, coupled with user-friendly operational features and remote access capabilities, positions the EverFocus EFC--02-1-A as a leading choice for organizations aiming to enhance their surveillance setups.