Set Time __:__:__

Set System PIN

A System PIN must be entered before the user can make management changes via the controller keypad. The factory default System PIN is 000000. It is recommended that the password is changed after the initial log-in for maximum security. Be sure to keep the new password; if lost the system can only be accessed after purging all stored data using CLR on the keypad.

Under the System Setting Menu, press ENT to set system PIN.

Set SYS PIN

The LCD will display the following menu.

Input:

______

Enter a new system PIN. Enter it a second time to confirm. Press ENT to set the new system PIN. Pressing CLR at any time will exit the menu without changing the system PIN.

Set Arm PIN

Arm PIN must be entered before the controller can be armed or disarmed via controller keypad. The factory default arm PIN is 000000.

Under System Setting menu, press ENT at the window below to set arm PIN.

Set ARM PIN

The LCD will display the following menu.

Input:

______

Enter a new arm PIN. Enter it a second time to confirm. Press ENT to set the new arm PIN.

Erase All Events

The controller will record all events that occur, beginning immediately upon powering on. These events can be purged by following the instructions below. If the

37

Image 45
Contents Flex Series Controller EFC-02-1A Instruction Guide Table of Contents Chapter Page ARM/DISARM Specifications FederalCommunication Commission Interference Statement Product Overview FeaturesParts List Controller Layout Main module Controller LayoutPage Preparing for the Installation Installation ReviewPreparing for the Installation Obtain a Floor PlanDetermining Hardware and Location Entry Card Readers Mounting the Enclosure and Controller Hardware InstallationStep Install a New Module to Controller Installing a Module to ControllerReader/Door Index Conversion Terminal / LED DefinitionsMain Module Terminal Definition Terminal name Function No Terminal name Main Module LED DefinitionLED Meaning Door Module Terminal DefinitionDefinitions of the Door Module Terminals Door Module LED DefinitionTerminal Function Name Alarm Module Terminal DefinitionAlarm Module LED Definition Install and Connecting the ReadersWiegand 26 Format RS232 FormatConnection to an Electric Strike Connection to Door LockConnection to a Magnetic Lock Connection to Door SensorConnection to Fire & Alarm Input Connection to Alarm InputConnection to Request-to-Exit 14 Connecting Alarm-sensor to Controller Connection to Alarm Output16 Normally Closed Connections for Alarm Output Connection to Computer via RS232 Connecting Controller ComputerRS485 Bus Based Networking System Connection to Desktop Reader via RS485RS485 Bus Extension Two Incorrect Connections Connection to Multiple Controllers via RS485Connection to Multiple Controllers via RS485 TCP/IP Based SystemPage Connecting the Power Supply Connecting PowerMount a Backup Battery optional Connection to Backup BatteryReset Controller Before First Use Cover PlacementPage General Operation Guideline Enter System ConfigurationDisplay the Number of Installed Modules Main Setting ItemsDisplay the Firmware Version System Setting Enter System Setting MenuSet Date Format Set Date Auto Daylight Savings TimeSet Time Set System PIN Set Arm PINErase All Events Card Setting Reset All Data and SettingsEnter Card Setting Menu Add Cards Delete CardsDelete a Card by Serial Number Status Setting Set Card PropertiesDelete All Cards Access Right Setting Group SettingSet Card PIN Setting Anti Passback APB Setting Enter Reader Setting Menu Reader SettingCard ARM Setting Show Card NumberReader to Door Allocation Keypad SettingSystem Reader Setting Door SettingEnter Door Setting Menu Open Time SettingSet Door Hold Open Time Set Door Behavior at Fire AlarmAlarm Setting Components for AlarmAlarm Configuration Basics Alarm Setting Menu Structure Enter Alarm Setting MenuEnter Alarm Action Setting Sub-menu Fire Alarm Enter Extended Alarm Setting Sub-menuZone Alarm 1~8 SYS PIN FailARM PIN Fail Remote Alarm AlarmUnknown Card Expired CardInvalid Door Invalid CardInvalid Time Card Anti-Passback FailCard PIN Fail Door Forced OpenDoor Held Open Enter Alarm Time Setting Sub-menu Armzone SettingEnter Armzone Setting Menu Reader LostSet Active Armzone Set ARM Delay TimeArm the System using the Controller Keypad Address SettingClear the Alarm Disarm the System using the Controller KeypadYellow LED Status System ARM Status Arm/Disarm the System using a ReaderPage Install the Software in the Control Computer Software SetupConfigure the Controller and All Other Hardware Setup the User Accounts for the SoftwareEnroll Cards Page Page Page EverAccess

EFC--02-1-A specifications

The EverFocus EFC--02-1-A is an advanced video surveillance solution designed to meet the high demands of modern security systems. This device stands out for its robust features, cutting-edge technologies, and exceptional reliability, making it ideal for a wide range of surveillance applications, from retail environments to industrial facilities.

One of the primary features of the EFC--02-1-A is its superior image quality. Equipped with high-definition video capabilities, the camera can capture crystal-clear images even in low-light conditions, thanks to its advanced low-light technology. This ensures that vital details are recorded, enhancing the overall effectiveness of surveillance efforts. The device boasts a wide dynamic range (WDR), which allows it to handle scenes with both bright and dark areas, maintaining image clarity and detail regardless of lighting variations.

The EFC--02-1-A also supports multi-streaming capabilities, enabling simultaneous transmission of multiple video streams in different resolutions. This versatility is particularly advantageous for network bandwidth management, allowing users to customize their surveillance setup according to specific requirements. The integration of advanced compression technologies such as H.265 ensures efficient use of storage while maintaining high video quality.

Durability is another hallmark of the EFC--02-1-A. The camera is designed to withstand harsh environmental conditions, featuring an IP67-rated enclosure that protects it from dust and water ingress. This weatherproof design makes it suitable for both indoor and outdoor installations, ensuring uninterrupted operation in various settings.

Moreover, the EFC--02-1-A comes equipped with smart analytics capabilities, including motion detection and face recognition technologies. These features enhance the system’s functionality by enabling automatic alerts and efficient monitoring of specific areas, thereby reducing the workload for security personnel.

Lastly, seamless integration is a core characteristic of the EFC--02-1-A. It is compatible with multiple video management systems (VMS) and can easily connect with other security devices, promoting a holistic security ecosystem. This interoperability, coupled with user-friendly operational features and remote access capabilities, positions the EverFocus EFC--02-1-A as a leading choice for organizations aiming to enhance their surveillance setups.