Enterasys Networks C2RPS-SYS manual RPS Deployment Strategies

Page 20

RPS Deployment Strategies

RPS Deployment Strategies

The RPS can be deployed in a variety of situations with mission‐critical applications. For example:

For use in a voice and data network where switches are connected to IP phones and PCs. Connecting an RPS to the switches can prevent voice network failures caused by switch failures.

For use in traditional data 10/100/1000 Ethernet switches carrying mission‐critical data.

These applications would typically use one RPS to support up to eight SecureStack C2 switch devices as shown in Figure 1‐5. If a SecureStack C2 switch device experiences an internal power‐supply failure, the following occurs:

1.The SecureStack C2 switch device internal DC‐power source is immediately switched over from the internal DC‐power supply to the RPS DC‐power input.

2.The SecureStack C2 switch device saves this status information for future retrieval, if necessary.

Figure 1-5 RPS Supporting a Group of Switches (up to eight)

Â

Á

À

C2RPS-CHAS8

Power

Power

Power

Power

Power

Power

Power

Power

C2RPS-PSM

C2RPS-PSM

C2RPS-PSM

C2RPS-PSM

C2RPS-PSM

C2RPS-PSM

C2RPS-PSM

C2RPS-PSM

1 C2RPS-CHAS8 chassis (front view with eight PSMs) 3 SecureStack C2 Ethernet switches

2C2RPS-PSM Cables for 12 Vdc and status information from PSMs

1-4 Introduction

Image 20
Contents SecureStack C2 Redundant Power System Page Page Regulatory Compliance Information Electromagnetic Compatibility EMC Declaration of Conformity Enterasys Networks, Inc Firmware License Agreement Page Vii Viii Contents Figures Structure of This Guide Using This GuideAbout this Guide Using the SecureStack C2 Manual Set Conventions Used in This Guide Following conventions are used in this guideConventions Used in This Guide Xiv About this Guide Introduction RPS OverviewPower supply slot cover Captive screw 2 per cover C2RPS-CHAS8 ChassisC2RPS-PSM Power Supply Module C2RPS-PSM front viewRPS Supporting a Group of Switches up to eight RPS Deployment StrategiesGetting Help Support@enterasys.comGetting Help Introduction Required Tools InstallationUnpacking Chassis and Power Supply Modules Installing C2RPS-PSMs Replacing an Installed C2RPS-PSM C2RPS-PSM InstallationInstalling C2RPS-CHAS8 into the Rack Guidelines for Rackmount InstallationRack Mounting the Chassis Connecting the PSM Cables and AC Power Cords Fastening the C2RPS-CHAS8 to the RackC2RPS-PSM Cable C2RPS-PSM Cable and AC Power Cord Connections Specifications C2RPS-CHAS8 Chassis SpecificationsC2RPS-PSM Specifications C2RPS-PSM Redundant Power Supply Output ConnectorCompliance Standards Table A-4 Compliance StandardsCompliance Standards Specifications