Enterasys Networks C2RPS-SYS manual C2RPS-PSM Specifications

Page 32

C2RPS-PSM Specifications

C2RPS-PSM Specifications

Refer to Table A‐2 for the input/output port specifications.

Table A-2 C2RPS-PSM Specifications

Item

Specification

 

 

 

Electrical

 

 

 

 

 

AC Input Frequency Range

47

- 63 Hz

AC Input Voltage Range

85

- 264 Vac

Output Voltage

12

Vdc

Output Current

1.0 A min., 8.5 A or 13.0 A max.

Maximum Output Power

102 W or 156 W continuous

 

 

 

Physical

 

 

 

 

Dimensions

19.6 H x 5.2 W x 25.7 D (cm)

 

7.7 H x 2.04 W x 10.1 D (in.)

Net Weight (Unit Only)

1.75 kg (3.85 lb)

Gross Weight (Packaged Unit)

3.20 kg (7.04 lb)

 

 

MTBF

300,000 Hours

 

 

 

C2RPS-PSM Redundant Power Supply Output Connector

For pin location and function, refer to Figure A‐1 and Table A‐3, respectively.

Note: The following information is for troubleshooting purposes only. For proper operation, do not use any other cable except the C2RPS-PSM Cable. This cable is specially designed for this application and meets all necessary Regulatory and Safety standards. The use of non-approved cables will void your warranty.

Figure A-1 C2RPS-PSM Redundant Power Supply Connector Pin Locations

148

71

A-2 Specifications

Image 32
Contents SecureStack C2 Redundant Power System Page Page Regulatory Compliance Information Electromagnetic Compatibility EMC Declaration of Conformity Enterasys Networks, Inc Firmware License Agreement Page Vii Viii Contents Figures Structure of This Guide Using This GuideAbout this Guide Using the SecureStack C2 Manual Set Conventions Used in This Guide Following conventions are used in this guideConventions Used in This Guide Xiv About this Guide Introduction RPS OverviewPower supply slot cover Captive screw 2 per cover C2RPS-CHAS8 ChassisC2RPS-PSM Power Supply Module C2RPS-PSM front viewRPS Supporting a Group of Switches up to eight RPS Deployment StrategiesGetting Help Support@enterasys.comGetting Help Introduction Required Tools InstallationUnpacking Chassis and Power Supply Modules Installing C2RPS-PSMs Replacing an Installed C2RPS-PSM C2RPS-PSM InstallationInstalling C2RPS-CHAS8 into the Rack Guidelines for Rackmount InstallationRack Mounting the Chassis Connecting the PSM Cables and AC Power Cords Fastening the C2RPS-CHAS8 to the RackC2RPS-PSM Cable C2RPS-PSM Cable and AC Power Cord Connections Specifications C2RPS-CHAS8 Chassis SpecificationsC2RPS-PSM Specifications C2RPS-PSM Redundant Power Supply Output ConnectorCompliance Standards Table A-4 Compliance StandardsCompliance Standards Specifications