Enterasys Networks manual Installing the 7H4385-49 into Matrix N1, N3, or N5 Chassis

Page 41

Preparing to Install into a Matrix E7, N1, N3, N5, or N7 Chassis

Installing the 7H4385-49 into Matrix N1, N3, or N5 Chassis

Caution: Failure to observe static safety precautions could cause damage to the module. Follow static safety handling rules and wear the antistatic wrist strap.

Do not cut the non-conductive bag to remove the module. Sharp objects contacting the board or components can cause damage.

Precaución: Si no toma las medidas de seguridad necesarias para evitar descargas de electricidad estática, es posible que el módulo se dañe. Siga los consejos de seguridad para la manipulación del producto y no olvide utilizar la pulsera antiestática.

No corte la bolsa antiestática para sacar el módulo. Tenga en cuenta que si algún objeto cortante entra en contacto con la placa o con los componentes, éstos podrían dañarse.

A DFE module can be installed in any available chassis slot (1 through 3) in the Matrix N3 chassis, or slots 1 through 5 in the Matrix N5 chassis, or into the single slot of the Matrix N1 chassis. All chassis have horizontal slots for DFE modules. To install the module into the Matrix N3, N5, or N1 chassis, refer to Figure 3‐3 and proceed as described in “Preparing to Install into a Matrix E7, N1, N3, N5, or N7 Chassis” on page 3‐7.

1.Prepare the DFE module using the procedure described in “Preparing to Install into a Matrix E7, N1, N3, N5, or N7 Chassis” on page 3‐7.

Caution: When setting the locking levers to the closed position, do not try to force the locking levers to the point that they touch the face of the front panel. Forcing the locking levers to this point could damage the module and chassis.

Precaución: Al mover las palancas a la posición de cerrado, tenga cuidado de no llevarlas a un punto en donde estén en contacto con el panel frontal. Si lo hace, podría dañar el módulo o el chasis.

Electrical Hazard: To prevent exposure to an energy hazard in a 7H4385-49 connected to an external N-POE Power System, disconnect the 48-Vdc power cable from the 48-Vdc input connector before servicing or removing the 7H4385-49.

Riesgo Eléctrico: Para prevenir la exposicion a un riesgo electrico en una tarjeta 7H4385-49 conectada a un sistema externo de energia N-POE Power System, desconectar el cable de poder de 48-Vdc del conector de entrada 48-Vdc antes de dar servicio o remover la tarjeta 7H4385-49.

Elektrischer Gefahrenhinweis: Um den Schutz vor el. Schäden des Moduls

(7H4385-49) zu gewähleisten, bei Verwendung der N-POE Systeme, sollte dies bevor man dieses entnimmt oder Servicearbeiten daran vornimmt, vom 48-Vdc Stecker getrennt werden.

2.Locate the chassis card guides that line up with the slot number in which the module will be installed. Make sure the module locking levers are in the open position (top and bottom).

DFE-Platinum Series Hardware Installation Guide 3-11

Image 41
Contents Enterasys Matrix Page Page Federal Communications Commission FCC Notice Product SafetyIndustry Canada Notice Class a ITE Notice Clase A. Aviso de ITEElektro- magnetische Kompatibilität EMC Electromagnetic Compatibility EMCCompatibilidad Electromágnetica EMC Supplement to Product Instructions Bsmi EMC Statement Taiwan Safety Information Class 1 Laser TransceiversVcci Notice USA Declaration of ConformityEnterasys NETWORKS, INC. Firmware License Agreement Viii Page Page Contents Appendix a Specifications TroubleshootingAppendix B Mode Switch Settings and Option Installations Appendix C About PoE Power over EthernetTables FiguresXiv Important Notice About This GuideWho Should Use This Guide For Refer to How to Use This GuideRelated Documents Following conventions are used in this guide Conventions Used in This GuideSupport@enterasys.com Getting HelpFor information about Refer to IntroductionOverview of DFE-Platinum Series Module Capabilities DFE-Platinum 7H4385-49 PoE Module 7H4385-49 DFE-Platinum Module Switch Configuration Using CLI Commands Switch Configuration Using WebViewConnectivity ManagementSecure Networks Policy Support Lanview Diagnostic LEDsLink Aggregation Network Requirements10BASE-T Network Module Placement in a Matrix E7 ChassisFTM Bridge Function and Optional Interface Module 100BASE-TX Network 100BASE-TX Network Network Requirements Installation Unpacking the DFE Module Installation Site RequirementContents of 7H4385-49 Module Carton Quantity FTM1 and FTM2 Connectivity Installing Optional Network Expansion Module NEMBackplane Connections and Installation Rules Example 1 -1,A Module Placement and Installation RulesMatrix E7 Chassis Module Placement Example 4 -1,D Example 2 -1,BExample 3 -1, C Example 6 -1, F Example 5 -1, EDFE-Platinum Series Hardware Installation Guide To install the 7H4385‐49, refer to ‐2 and proceed as follows DFE-Platinum Series Hardware Installation Guide No bottom connectors in Matrix N7chassis Installing the 7H4385-49 into Matrix N1, N3, or N5 Chassis Installation Installing Module into Matrix N3, N5, or N1 Chassis N3 shown Connecting 48 Vdc Power for PoE Operation Connecting UTP Cables to 7H4385-49 Connecting to the NetworkMaking the UTP Connections Connecting a Twisted Pair Segment with RJ45 ConnectorRX+ TX+ TX1+ RX1 TX2+ TX3+ RX3 RX2 TX4+ RX4 Verifying PoE Port Status Connecting to an IBM PC or Compatible Device Connecting to COM Port for Local ManagementWhat Is Needed Parameter Setting Connecting to a VT Series Terminal10 Connecting a VT Series Terminal Connecting to a Modem11 Connecting to a Modem COM Port Adapter Wiring and Signal Diagram RJ45 Adapter Wiring and Signal AssignmentsRJ45 DB25 Modem Port Adapter Wiring and Signal DiagramFirst-Time Log-In Using a Console Port Connection Completing the InstallationCompleting the Installation of a New System 12 Matrix DFE Startup Screen Example N7 Chassis Enter Logging in with an Administratively-Configured User AccountAbout the Management Mgmt LED TroubleshootingUsing Lanview Viewing the PoE Port Status Viewing the Receive and Transmit ActivityColor State Recommended Action LEDAmber and Alternating 67% on, 33% RX/TX Indications in Standard ModeRX/TX DFE-Platinum Series Configuration Guide Troubleshooting ChecklistProblem Possible Cause Recommended Action Troubleshooting ChecklistOverview of DFE Module Shutdown Procedure OFFLINE/RESET Switch Recommended Shutdown Procedure Using OFFLINE/RESET SwitchLast Resort Shutdown Procedure Using OFFLINE/RESET Switch DFE Module Specifications SpecificationsTable A-1 7H4385-49 Specifications Processors/MemoryTable A-2 COM Port Pin Assignments Signal Name Input/Output Table A-1 7H4385-49 Specifications PhysicalCOM Port Pinout Assignments EnvironmentalTable A-3 Compliance Standards Regulatory Compliance Regulatory ComplianceRegulatory Compliance Specifications Required Tools Mode Switch Settings and Option InstallationsSetting the Mode Switches Memory Locations and Replacement Procedures Memory Locations and Replacement ProceduresGaining Access to Memory Modules Gaining Access to Memory ModulesRemoving the Safety Cover Figure B-3 Removing the Safety Cover Removing the Optional Network Expansion Module NEM Dram Simm Replacement ProcedureFigure B-5 Removing the Existing Dram Simm Removing the Dram SimmFigure B-6 Installing the Dram Simm Installing the Dram SimmRemoving the Dimm Dimm Replacement ProcedureInstalling the Dimm Installing the Network Expansion Module NEMFigure B-9 Installing the Network Expansion Module Reinstalling the Safety Cover Figure B-10 Installing the Safety Cover Overview About PoE Power over EthernetProprietary PD Detection Table C-2 PoE Status LED Indications PoE Port Status PoE Port Status LEDsOverview About PoE Power over Ethernet Numerics IndexPinout assignments console port A-2