Enterasys Networks 7H4385-49 manual Overview of DFE Module Shutdown Procedure

Page 66

Overview of DFE Module Shutdown Procedure

Table 4-2 Troubleshooting Checklist (continued)

Problem

Possible Cause

Recommended Action

 

 

 

User parameters (IP

Position of Mode switch (7),

address, device and

Persistent Data Reset, was

module name, etc.)

changed sometime before

were lost when the

either cycling power or

module power was

pressing the OFFLINE/RESET

cycled, the front

switch, causing the user-

panel OFFLINE/

entered parameters to reset to

RESET switch was

factory default settings.

pressed.

Clear Persistent Data that was

 

 

set through Local

 

Management.

 

The DFE module was moved

 

either from slot-to-slot or from

 

chassis-to-chassis.

Reenter the lost parameters as necessary. Refer to the Enterasys Matrix DFE-Platinum Series Configuration Guide for the instructions to configure the DFE module.

If the problem continues, contact Enterasys Networks for technical support.

Overview of DFE Module Shutdown Procedure

Caution: Do not remove a DFE module from an operating chassis system before reading the following information and instructions.

Precaución: Antes de retirar los módulos DFE del chasis en funcionamiento, lea las siguientes instrucciones y la información suministrada.

The DFE modules installed in a Matrix E7, Matrix N3, Matrix N5, or Matrix N7 chassis are interdependent and operate under a single IP address as a single, distributed switch system (hardware, databases, and persistent storage). In this operating environment, the DFE module must shut down in an orderly fashion to ensure that the other modules in the system and other devices on the network are notified of the impending change. The device(s) can then make intelligent decisions and stabilize the network before the change is made, thereby increasing network availability.

You can shut down a DFE module in an operating system using the OFFLINE/RESET switch shown in Figure 4‐2. There are two procedures to shut down a DFE module.

Recommended shutdown procedure (“Recommended Shutdown Procedure Using OFFLINE/RESET Switch” on page 4‐9)

Last resort shutdown procedure (not recommended) (“Last Resort Shutdown Procedure Using OFFLINE/RESET Switch” on page 4‐10)

4-8 Troubleshooting

Image 66
Contents Enterasys Matrix Page Page Industry Canada Notice Product SafetyFederal Communications Commission FCC Notice Class a ITE Notice Clase A. Aviso de ITEElectromagnetic Compatibility EMC Compatibilidad Electromágnetica EMCElektro- magnetische Kompatibilität EMC Supplement to Product Instructions Safety Information Class 1 Laser Transceivers Vcci NoticeBsmi EMC Statement Taiwan Declaration of Conformity USAEnterasys NETWORKS, INC. Firmware License Agreement Viii Page Page Contents Appendix B Mode Switch Settings and Option Installations TroubleshootingAppendix a Specifications Appendix C About PoE Power over EthernetFigures TablesXiv About This Guide Who Should Use This GuideImportant Notice How to Use This Guide Related DocumentsFor Refer to Conventions Used in This Guide Following conventions are used in this guideGetting Help Support@enterasys.comIntroduction For information about Refer toOverview of DFE-Platinum Series Module Capabilities DFE-Platinum 7H4385-49 PoE Module 7H4385-49 DFE-Platinum Module Connectivity Switch Configuration Using WebViewSwitch Configuration Using CLI Commands ManagementLanview Diagnostic LEDs Secure Networks Policy SupportNetwork Requirements Link AggregationModule Placement in a Matrix E7 Chassis FTM Bridge Function and Optional Interface Module10BASE-T Network 100BASE-TX Network 100BASE-TX Network Network Requirements Installation Installation Site Requirement Contents of 7H4385-49 Module Carton QuantityUnpacking the DFE Module Installing Optional Network Expansion Module NEM Backplane Connections and Installation RulesFTM1 and FTM2 Connectivity Module Placement and Installation Rules Matrix E7 Chassis Module PlacementExample 1 -1,A Example 2 -1,B Example 3 -1, CExample 4 -1,D Example 5 -1, E Example 6 -1, FDFE-Platinum Series Hardware Installation Guide To install the 7H4385‐49, refer to ‐2 and proceed as follows DFE-Platinum Series Hardware Installation Guide No bottom connectors in Matrix N7chassis Installing the 7H4385-49 into Matrix N1, N3, or N5 Chassis Installation Installing Module into Matrix N3, N5, or N1 Chassis N3 shown Connecting 48 Vdc Power for PoE Operation Connecting to the Network Connecting UTP Cables to 7H4385-49Connecting a Twisted Pair Segment with RJ45 Connector Making the UTP ConnectionsRX+ TX+ TX1+ RX1 TX2+ TX3+ RX3 RX2 TX4+ RX4 Verifying PoE Port Status Connecting to COM Port for Local Management What Is NeededConnecting to an IBM PC or Compatible Device Connecting to a VT Series Terminal Parameter SettingConnecting to a Modem 10 Connecting a VT Series Terminal11 Connecting to a Modem Adapter Wiring and Signal Assignments COM Port Adapter Wiring and Signal Diagram RJ45Modem Port Adapter Wiring and Signal Diagram RJ45 DB25Completing the Installation Completing the Installation of a New SystemFirst-Time Log-In Using a Console Port Connection 12 Matrix DFE Startup Screen Example N7 Chassis Logging in with an Administratively-Configured User Account EnterTroubleshooting Using LanviewAbout the Management Mgmt LED Viewing the Receive and Transmit Activity Viewing the PoE Port StatusLED Color State Recommended ActionRX/TX Indications in Standard Mode Amber and Alternating 67% on, 33%RX/TX Troubleshooting Checklist DFE-Platinum Series Configuration GuideTroubleshooting Checklist Problem Possible Cause Recommended ActionOverview of DFE Module Shutdown Procedure Recommended Shutdown Procedure Using OFFLINE/RESET Switch OFFLINE/RESET SwitchLast Resort Shutdown Procedure Using OFFLINE/RESET Switch Table A-1 7H4385-49 Specifications SpecificationsDFE Module Specifications Processors/MemoryCOM Port Pinout Assignments Table A-1 7H4385-49 Specifications PhysicalTable A-2 COM Port Pin Assignments Signal Name Input/Output EnvironmentalRegulatory Compliance Table A-3 Compliance Standards Regulatory ComplianceRegulatory Compliance Specifications Mode Switch Settings and Option Installations Required ToolsSetting the Mode Switches Memory Locations and Replacement Procedures Memory Locations and Replacement ProceduresGaining Access to Memory Modules Gaining Access to Memory ModulesRemoving the Safety Cover Figure B-3 Removing the Safety Cover Dram Simm Replacement Procedure Removing the Optional Network Expansion Module NEMRemoving the Dram Simm Figure B-5 Removing the Existing Dram SimmInstalling the Dram Simm Figure B-6 Installing the Dram SimmDimm Replacement Procedure Removing the DimmInstalling the Network Expansion Module NEM Installing the DimmFigure B-9 Installing the Network Expansion Module Reinstalling the Safety Cover Figure B-10 Installing the Safety Cover About PoE Power over Ethernet OverviewProprietary PD Detection PoE Port Status LEDs Table C-2 PoE Status LED Indications PoE Port StatusOverview About PoE Power over Ethernet Index NumericsPinout assignments console port A-2