Enterasys Networks 7H4385-49 manual Verifying PoE Port Status

Page 49

Connecting to the Network

Figure 3-8 Eight-Wire Straight-Through Cable RJ45 Pinouts, Connections Between Switches and End User Devices

ÀÁ

TX1+ 1

RX1- 2

TX2+ 3

TX3+ 4

RX3- 5

RX2- 6

TX4+ 7

RX4- 8

1RJ45 device port

2Other device port

1

TX2+

2

RX2-

3

TX1+

4

TX4+

5

RX4-

6

RX1-

7

TX3+

8

RX3-

Â

3RJ45-to-RJ45 straight-through cable

f.Ensure that the twisted pair connection meets the dB loss and cable specifications outlined in the Cabling Guide. Refer to “Related Documents” in About This Guide for information on obtaining this document.

If a link is not established and it is connected to a PD (Powered Device), check the PoE Port Status to ensure that there is 48 Vdc power at the 7H4385‐49 RJ45 port. Refer to “Verifying PoE Port Status” on page 3‐19. If there is still a problem, contact Enterasys Networks. Refer to “Getting Help” on page xviii for details.

4.Repeat steps 1 through 3 above, until all connections have been made.

Verifying PoE Port Status

If a PD is connected to the 7H4385‐49 RJ45 port, ensure that there is power at the RJ45 port as follows:

1.Press on the GROUP SELECT switch for more than one second. The 7H4385‐49 will enter the PoE status mode, which will indicate a set of power status conditions relating to the PoE Port Status.

2.Now, every time you press the GROUP SELECT switch for less than a second, the GROUP LED lights up in sequence, indicating which group is selected. The PoE POWER STATUS for that group of segments is then indicated by the RX and TX LEDs for each segment. If there is power at the port, the RX LED is green and the TX LED is off. Otherwise, refer to Chapter 4 for troubleshooting information.

DFE-Platinum Series Hardware Installation Guide 3-19

Image 49
Contents Enterasys Matrix Page Page Federal Communications Commission FCC Notice Product SafetyIndustry Canada Notice Class a ITE Notice Clase A. Aviso de ITECompatibilidad Electromágnetica EMC Electromagnetic Compatibility EMCElektro- magnetische Kompatibilität EMC Supplement to Product Instructions Vcci Notice Safety Information Class 1 Laser TransceiversBsmi EMC Statement Taiwan USA Declaration of ConformityEnterasys NETWORKS, INC. Firmware License Agreement Viii Page Page Contents Appendix a Specifications TroubleshootingAppendix B Mode Switch Settings and Option Installations Appendix C About PoE Power over EthernetTables FiguresXiv Who Should Use This Guide About This GuideImportant Notice Related Documents How to Use This GuideFor Refer to Following conventions are used in this guide Conventions Used in This GuideSupport@enterasys.com Getting HelpFor information about Refer to IntroductionOverview of DFE-Platinum Series Module Capabilities DFE-Platinum 7H4385-49 PoE Module 7H4385-49 DFE-Platinum Module Switch Configuration Using CLI Commands Switch Configuration Using WebViewConnectivity ManagementSecure Networks Policy Support Lanview Diagnostic LEDsLink Aggregation Network RequirementsFTM Bridge Function and Optional Interface Module Module Placement in a Matrix E7 Chassis10BASE-T Network 100BASE-TX Network 100BASE-TX Network Network Requirements Installation Contents of 7H4385-49 Module Carton Quantity Installation Site RequirementUnpacking the DFE Module Backplane Connections and Installation Rules Installing Optional Network Expansion Module NEMFTM1 and FTM2 Connectivity Matrix E7 Chassis Module Placement Module Placement and Installation RulesExample 1 -1,A Example 3 -1, C Example 2 -1,BExample 4 -1,D Example 6 -1, F Example 5 -1, EDFE-Platinum Series Hardware Installation Guide To install the 7H4385‐49, refer to ‐2 and proceed as follows DFE-Platinum Series Hardware Installation Guide No bottom connectors in Matrix N7chassis Installing the 7H4385-49 into Matrix N1, N3, or N5 Chassis Installation Installing Module into Matrix N3, N5, or N1 Chassis N3 shown Connecting 48 Vdc Power for PoE Operation Connecting UTP Cables to 7H4385-49 Connecting to the NetworkMaking the UTP Connections Connecting a Twisted Pair Segment with RJ45 ConnectorRX+ TX+ TX1+ RX1 TX2+ TX3+ RX3 RX2 TX4+ RX4 Verifying PoE Port Status What Is Needed Connecting to COM Port for Local ManagementConnecting to an IBM PC or Compatible Device Parameter Setting Connecting to a VT Series Terminal10 Connecting a VT Series Terminal Connecting to a Modem11 Connecting to a Modem COM Port Adapter Wiring and Signal Diagram RJ45 Adapter Wiring and Signal AssignmentsRJ45 DB25 Modem Port Adapter Wiring and Signal DiagramCompleting the Installation of a New System Completing the InstallationFirst-Time Log-In Using a Console Port Connection 12 Matrix DFE Startup Screen Example N7 Chassis Enter Logging in with an Administratively-Configured User AccountUsing Lanview TroubleshootingAbout the Management Mgmt LED Viewing the PoE Port Status Viewing the Receive and Transmit ActivityColor State Recommended Action LEDAmber and Alternating 67% on, 33% RX/TX Indications in Standard ModeRX/TX DFE-Platinum Series Configuration Guide Troubleshooting ChecklistProblem Possible Cause Recommended Action Troubleshooting ChecklistOverview of DFE Module Shutdown Procedure OFFLINE/RESET Switch Recommended Shutdown Procedure Using OFFLINE/RESET SwitchLast Resort Shutdown Procedure Using OFFLINE/RESET Switch DFE Module Specifications SpecificationsTable A-1 7H4385-49 Specifications Processors/MemoryTable A-2 COM Port Pin Assignments Signal Name Input/Output Table A-1 7H4385-49 Specifications PhysicalCOM Port Pinout Assignments EnvironmentalTable A-3 Compliance Standards Regulatory Compliance Regulatory ComplianceRegulatory Compliance Specifications Required Tools Mode Switch Settings and Option InstallationsSetting the Mode Switches Memory Locations and Replacement Procedures Memory Locations and Replacement ProceduresGaining Access to Memory Modules Gaining Access to Memory ModulesRemoving the Safety Cover Figure B-3 Removing the Safety Cover Removing the Optional Network Expansion Module NEM Dram Simm Replacement ProcedureFigure B-5 Removing the Existing Dram Simm Removing the Dram SimmFigure B-6 Installing the Dram Simm Installing the Dram SimmRemoving the Dimm Dimm Replacement ProcedureInstalling the Dimm Installing the Network Expansion Module NEMFigure B-9 Installing the Network Expansion Module Reinstalling the Safety Cover Figure B-10 Installing the Safety Cover Overview About PoE Power over EthernetProprietary PD Detection Table C-2 PoE Status LED Indications PoE Port Status PoE Port Status LEDsOverview About PoE Power over Ethernet Numerics IndexPinout assignments console port A-2