Enterasys Networks manual 7H4385-49 DFE-Platinum Module

Page 24

DFE-Platinum 7H4385-49 PoE Module

Figure 1-1 7H4385-49 DFE-Platinum Module

FAST ENET

7H4385-49

1

11X

13X

G R O U P

2

23X

25X

G R O U P

3

35X

37X

G

R

DFE

OFFLINE/À

RESET

Á

 

 

 

 

 

COM

 

 

 

 

 

 

 

 

 

 

Â

 

 

 

 

 

 

 

MGMT

 

 

 

CPU

Ã

 

 

 

 

 

 

POE

 

 

 

 

 

 

 

 

 

 

GROUP

 

Ä

 

 

 

 

 

 

 

 

GROUP

 

 

SELECT

Å

 

 

 

 

 

 

 

 

 

 

1

 

1

 

 

 

 

2

 

2

 

 

 

 

3

 

3

 

 

 

 

4

 

4

 

 

 

 

 

 

5

 

Æ

 

 

7

 

 

 

6

 

 

 

 

 

 

8

 

 

 

 

 

 

9

 

 

 

 

 

 

10

 

 

 

 

 

11

 

 

 

 

 

12

 

 

Ç

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14X

 

 

 

 

 

 

24X

26X

È

36X

38X

48X

É

48V --- 20A MAX OPTIONAL POWER INPUT

1

OFFLINE/RESET switch

7

GROUP STATUS LEDs

2

RJ45 COM port

8

GROUP SELECT LEDs

3

MGMT LED

9

NEM option slot

4

CPU LED

10

48 Vdc ~ 20 A Max. Optional Power Input

5

PoE LED

 

connector

6

GROUP SELECT switch

11

Ports (1-48), 10/100 Mbps, through RJ45s

1-4 Introduction

Image 24
Contents Enterasys Matrix Page Page Product Safety Federal Communications Commission FCC NoticeIndustry Canada Notice Class a ITE Notice Clase A. Aviso de ITEElectromagnetic Compatibility EMC Compatibilidad Electromágnetica EMCElektro- magnetische Kompatibilität EMC Supplement to Product Instructions Safety Information Class 1 Laser Transceivers Vcci NoticeBsmi EMC Statement Taiwan Declaration of Conformity USAEnterasys NETWORKS, INC. Firmware License Agreement Viii Page Page Contents Troubleshooting Appendix a SpecificationsAppendix B Mode Switch Settings and Option Installations Appendix C About PoE Power over EthernetFigures TablesXiv About This Guide Who Should Use This GuideImportant Notice How to Use This Guide Related DocumentsFor Refer to Conventions Used in This Guide Following conventions are used in this guideGetting Help Support@enterasys.comIntroduction For information about Refer toOverview of DFE-Platinum Series Module Capabilities DFE-Platinum 7H4385-49 PoE Module 7H4385-49 DFE-Platinum Module Switch Configuration Using WebView Switch Configuration Using CLI CommandsConnectivity ManagementLanview Diagnostic LEDs Secure Networks Policy SupportNetwork Requirements Link AggregationModule Placement in a Matrix E7 Chassis FTM Bridge Function and Optional Interface Module10BASE-T Network 100BASE-TX Network 100BASE-TX Network Network Requirements Installation Installation Site Requirement Contents of 7H4385-49 Module Carton QuantityUnpacking the DFE Module Installing Optional Network Expansion Module NEM Backplane Connections and Installation RulesFTM1 and FTM2 Connectivity Module Placement and Installation Rules Matrix E7 Chassis Module PlacementExample 1 -1,A Example 2 -1,B Example 3 -1, CExample 4 -1,D Example 5 -1, E Example 6 -1, FDFE-Platinum Series Hardware Installation Guide To install the 7H4385‐49, refer to ‐2 and proceed as follows DFE-Platinum Series Hardware Installation Guide No bottom connectors in Matrix N7chassis Installing the 7H4385-49 into Matrix N1, N3, or N5 Chassis Installation Installing Module into Matrix N3, N5, or N1 Chassis N3 shown Connecting 48 Vdc Power for PoE Operation Connecting to the Network Connecting UTP Cables to 7H4385-49Connecting a Twisted Pair Segment with RJ45 Connector Making the UTP ConnectionsRX+ TX+ TX1+ RX1 TX2+ TX3+ RX3 RX2 TX4+ RX4 Verifying PoE Port Status Connecting to COM Port for Local Management What Is NeededConnecting to an IBM PC or Compatible Device Connecting to a VT Series Terminal Parameter SettingConnecting to a Modem 10 Connecting a VT Series Terminal11 Connecting to a Modem Adapter Wiring and Signal Assignments COM Port Adapter Wiring and Signal Diagram RJ45Modem Port Adapter Wiring and Signal Diagram RJ45 DB25Completing the Installation Completing the Installation of a New SystemFirst-Time Log-In Using a Console Port Connection 12 Matrix DFE Startup Screen Example N7 Chassis Logging in with an Administratively-Configured User Account EnterTroubleshooting Using LanviewAbout the Management Mgmt LED Viewing the Receive and Transmit Activity Viewing the PoE Port StatusLED Color State Recommended ActionRX/TX Indications in Standard Mode Amber and Alternating 67% on, 33%RX/TX Troubleshooting Checklist DFE-Platinum Series Configuration GuideTroubleshooting Checklist Problem Possible Cause Recommended ActionOverview of DFE Module Shutdown Procedure Recommended Shutdown Procedure Using OFFLINE/RESET Switch OFFLINE/RESET SwitchLast Resort Shutdown Procedure Using OFFLINE/RESET Switch Specifications DFE Module SpecificationsTable A-1 7H4385-49 Specifications Processors/MemoryTable A-1 7H4385-49 Specifications Physical Table A-2 COM Port Pin Assignments Signal Name Input/OutputCOM Port Pinout Assignments EnvironmentalRegulatory Compliance Table A-3 Compliance Standards Regulatory ComplianceRegulatory Compliance Specifications Mode Switch Settings and Option Installations Required ToolsSetting the Mode Switches Memory Locations and Replacement Procedures Memory Locations and Replacement ProceduresGaining Access to Memory Modules Gaining Access to Memory ModulesRemoving the Safety Cover Figure B-3 Removing the Safety Cover Dram Simm Replacement Procedure Removing the Optional Network Expansion Module NEMRemoving the Dram Simm Figure B-5 Removing the Existing Dram SimmInstalling the Dram Simm Figure B-6 Installing the Dram SimmDimm Replacement Procedure Removing the DimmInstalling the Network Expansion Module NEM Installing the DimmFigure B-9 Installing the Network Expansion Module Reinstalling the Safety Cover Figure B-10 Installing the Safety Cover About PoE Power over Ethernet OverviewProprietary PD Detection PoE Port Status LEDs Table C-2 PoE Status LED Indications PoE Port StatusOverview About PoE Power over Ethernet Index NumericsPinout assignments console port A-2