Enterasys Networks 7G4285-49, 7G4205-72 manual Rx+ Tx+

Page 47

Connecting to the Network

e.Verify that the RJ45 connectors on the twisted pair segment have the proper pinouts and check the cable for continuity. Typically, a crossover cable is used between hub devices. A straight‐through cable is used to connect between switches or hub devices and an end user (computer). Refer to Figure 3‐5 and Figure 3‐6 for four‐wire RJ45 connections. Refer to Figure 3‐7 and Figure 3‐8 for eight‐wire RJ45 connections.

Figure 3-5 Four-Wire Crossover Cable RJ45 Pinouts, Connections Between Hub Devices

 

À

RX+

1

RX–

2

Ã

 

TX+

3

TX–

6

 

 

Â

Á

1RX+

2 RX–

3TX+

6 TX–

1 RJ45 device port 3 RJ45-to-RJ45 crossover cable

2 Other device port 4 RX+/RX- and TX+/TX- connections.

These connections must share a common color pair.

Figure 3-6 Four-Wire Straight-Through Cable RJ45 Pinouts, Connections Between Switches and End User Devices

ÀÁ

RX+ 1

RX– 2

Ã

TX+ 3

TX– 6

Â

1RX+

2 RX–

3TX+

6 TX–

1

RJ45 device port

3

RJ45-to-RJ45 straight-through cable

2

Other device port

4

RX+/RX- and TX+/TX- connections.

 

 

 

These connections must share a common color pair.

DFE-Platinum Series Hardware Installation Guide 3-15

Image 47
Contents Enterasys Matrix Page Page Class a ITE Notice Clase A. Aviso de ITE Product SafetyFederal Communications Commission FCC Notice Industry Canada NoticeHazardous Substances Electromagnetic Compatibility EMCCompatibilidad Electromágnetica EMC Elektro- magnetische Kompatibilität EMCSupplement to Product Instructions Bsmi EMC Statement Taiwan Vcci NoticeDeclaration of Conformity Safety Information Class 1 Laser TransceiversEnterasys NETWORKS, INC. Firmware License Agreement Viii Page Page Contents Appendix a Specifications Figures Xiv Who Should Use This Guide About This GuideFor Refer to How to Use This GuideRelated Documents Following conventions are used in this guide Conventions Used in This GuideSupport@enterasys.com Getting HelpOverview of DFE-Platinum Series Module Capabilities Introduction7G4285-49 DFE Module and Interface Options7G4285-49 DFE-Platinum Module 7G4205-72 7G4205-72 DFE-Platinum Module Management Switch Configuration Using WebViewNetwork Expansion Module NEM ConnectivityStandards Compatibility Switch Configuration Using CLI CommandsSecure Networks Policy Support Lanview Diagnostic LEDs Network Requirements 10BASE-T Network Link Aggregation1000BASE-T Network 100BASE-TX Network1000BASE-T Network Network Requirements Installation Unpacking the DFE Module Installation Site RequirementContents of DFE Module Carton Quantity Required ToolsMatrix E7 Chassis Module Placement Installing an Optional Network Expansion Module NEMDFE Module Placement and Installation Rules Example 3 -1, C Example 1 -1,AExample 2 -1,B Example 6 -1, F Example 4 -1,DExample 5 -1, E Preparing to Install into a Chassis Installing the DFE Modules into a Matrix E7 or N7 Chassis Preparing to Install into a Chassis Preparing to Install into a Chassis Installing the DFE Modules into a Matrix N3 or N5 Chassis Card guides Connecting to the Network Connecting 48 Vdc Power for PoE OperationMaking the UTP Connections Connecting UTP Cables to DFE ModulesConnecting a Twisted Pair Segment with RJ45 Connector RX+ TX+ TX1+ 1 RX1- 2 TX2+ 3 TX3+ 4 RX3- 5 RX2- 6 TX4+ 7 RX4 Verifying PoE Port Status Connecting to an IBM PC or Compatible Device Connecting to COM Port for Local ManagementWhat Is Needed Parameter Setting Connecting to a VT Series Terminal10 Connecting a VT Series Terminal Connecting to a Modem11 Connecting to a Modem RJ45 DB25 Adapter Wiring and Signal AssignmentsCOM Port Adapter Wiring and Signal Diagram RJ45 Modem Port Adapter Wiring and Signal Diagram First-Time Log-In Using a Console Port Connection Completing the InstallationCompleting the Installation of a New System 12 Matrix DFE Startup Screen Example N7 Chassis Enter Logging in with an Administratively-Configured User AccountAbout the Management Mgmt LED TroubleshootingUsing Lanview Lanview LEDs on 7G4285-49 Viewing Receive/Transmit Activity on 7G4285-49Lanview LEDs on 7G4205-72 Viewing Receive/Transmit Activity on 7G4205-72Viewing the PoE Port Status Color State Recommended Action Lanview LEDsLED RX/TX Platinum Series Configuration Guide for Troubleshooting ChecklistProblem Possible Cause Recommended Action Troubleshooting ChecklistOverview of DFE Module Shutdown Procedure OFFLINE/RESET Switch Recommended Shutdown Procedure Using OFFLINE/RESET SwitchLast Resort Shutdown Procedure Using OFFLINE/RESET Switch Specifications Physical DFE Module SpecificationsTable A-1 7G4285-49 Specifications Processors/MemoryTable A-2 7G4205-72 Specifications Table A-4 Compliance Standards Regulatory Compliance Table A-3 COM Port Pin Assignments Signal Name Input/OutputCOM Port Pinout Assignments Regulatory ComplianceMode Switch Settings and Option Installations Setting the Mode Switches Memory Locations and Replacement Procedures Dram Simm Dimm Removing the Safety Cover Gaining Access to Memory ModulesFigure B-3 Removing the Safety Cover Figure B-4 Removing the Optional Network Expansion Module Dram Simm Replacement ProcedureGaining Access to Memory Modules Removing the Dimm Figure B-6 Installing the Dimm Dimm Replacement ProcedureFigure B-7 Removing the Existing Dimm Figure B-8 Installing the Dimm Installing the Network Expansion Module NEMFigure B-9 Installing the Network Expansion Module NEM Reinstalling the Safety Cover Figure B-10 Installing the Safety Cover Page Overview About PoE Power over EthernetProprietary PD Detection Table C-2 PoE Status LED Indications PoE Port Status PoE Port Status LEDsOverview About PoE Power over Ethernet Numerics IndexNEM B-12 installing