Troubleshooting Checklist
Troubleshooting Checklist
If the module is not working properly, refer to Table 4‐2 on page 4‐8 for a checklist of problems, possible causes, and recommended actions to resolve the problem.
Table
Problem | Possible Cause | Recommended Action |
|
|
|
All LEDs are OFF. | Loss of power. | Ensure that the DFE module was installed |
|
| properly according to the installation |
|
| instructions in Chapter 3, and that the |
|
| host chassis is providing power. |
|
|
|
No Local | Incorrect terminal setup. | Refer to the Enterasys Matrix DFE- |
Management |
| Platinum Series Configuration Guide for |
Password screen. |
| proper setup procedures. |
|
|
|
| Improper console cable | Refer to Appendix A for proper COM port |
| pinouts. | pinouts. |
|
|
|
| Corrupt firmware image, or | If possible, attempt to download the |
| hardware fault. | image to the DFE module again. Refer to |
|
| “Setting the Mode Switches” on page |
|
| for instructions to clear NVRAM. |
|
|
|
Cannot navigate | Improper username/ password | If the username/password combination |
beyond Password | combination entered. | has been forgotten, refer to “Setting the |
screen. |
| Mode Switches” on page |
|
| instructions on how to set the mode |
|
| switch to reset the username/password |
|
| combination to the default values. |