Preparing to Install into a Chassis
5.Examine the module for damage. If any damage exists, DO NOT install the module. Immediately contact Enterasys Networks. Refer to “Getting Help” on page xviii.
6.To install a 7G4285‐49 or 7G4205‐72 into a Matrix E7, Matrix N7, or Matrix N7, proceed to “Installing the DFE Modules into a Matrix E7 or N7 Chassis” on page 3‐7. For Matrix N3, refer to “Installing the DFE Modules into a Matrix N3 or N5 Chassis” on page 3‐10.
Installing the DFE Modules into a Matrix E7 or N7 Chassis
To install the 7G4285‐49 or 7G4205‐72, refer to Figure 3‐2 and proceed as follows:
Caution: To prevent damaging the backplane connectors in the following step, take care that the module slides in straight and properly engages the backplane connectors.
Ensure that the top lever lines up with the desired slot number located on the front panel of the chassis. Refer to Figure
Precaución: Para evitar que se dañen los conectores del panel posterior en el siguiente paso, intente deslizar el módulo en forma recta y verifique que se enganche correctamente en los conectores de panel posterior.
Asegúrese de que la palanca superior esté alineada con respecto al número de ranura correspondiente ubicado en el panel frontal del chasis. Consulte en Figure
Electrical Hazard: To prevent exposure to an energy hazard in a
Riesgo Eléctrico: Para prevenir la exposicion a un riesgo electrico en una tarjeta
Elektrischer Gefahrenhinweis: Um den Schutz vor el. Schäden des Moduls
1.Prepare the chassis as described in “Preparing to Install into a Chassis” on page 3‐6.
2.Locate the chassis card guides that line up with the slot number in which the module will be installed. Make sure the module locking levers are in the open position (top and bottom).