Receiver Installation (BF units only)

1.Open steel curtain (remove glass doors if applicable).

2.Remove two (2) screws on log grate and remove log grate (Figure 1).

Figure 1

Screws

Manual Controls

3.Pull front edge of plastic ember bed grate up and forward until rear tab releases from the ledge located at the bottom of the partially reflective glass (Figure 2).

!NOTE: Log set fits tightly into firebox, some force may be necessary to remove.

Figure 2

 

Log

 

 

Back

 

ember

 

bed

ledge

 

 

 

Rear

 

 

tab

Side section

Front

 

edge

 

 

4.Locate and remove the two (2) screws on the manual control bracket (Figure 3). Remove the bracket.

5.Locate and depress the mounting tabs on the plug connector and remove the manual control bracket from fireplace (Figure 3).

Figure 3

Screw locations

 

Mounting tabs

Manual controls

Plug

connector

 

5

Image 5
Contents WRCPF-KIT Table of Contents Please carefully read and save these instructions Welcome & CongratulationsBF33STP BF33DXP BF39STP BF39DXP BF45DXP Product OverviewReceiver Installation BF units only Antenna Required Tools and Hardware Wall Control InstallationBattery Powered Installation Outer Hard Wired Power Supplied Installation Wall Control Installation Locking Screw Option Figure Wire leads Wall Control Installation BLF50 Models BF Models Using the Included Receiver ModuleInitialization Manual Controls OperationDF3033ST and DFG3033 Models LED Indicators Manual Selection SwitchOn Button Off ButtonRoom Temperature Wall Switch Remote Control Display OperationPurifire Icon Set TemperatureFlame Effect Icon Hour Sleep Timer RF Code Function and Change ProcedureWarranty