Digital Media 900TL Cabling, DEChub 900 MultiSwitch Configuration, DEChub ONE Configurations

Page 11

Cabling

Table 1 lists the Token Ring industry guideline for the maximum lobe length of shielded twisted-pair (STP) and unshielded twisted-pair (UTP) cable.

Table 1 Industry Lobe Length Guideline

Speed

UTP

 

STP

Level 3

 

Level 5

 

 

 

 

 

 

4 Mb/s

100 m (327 ft)

 

100 m (327 ft)

100 m (327 ft)

16 Mb/s

65 m (213 ft)

 

100 m (327 ft)

100 m (327 ft)

 

 

 

 

 

Lobe lengths for Digital's MAUs exceed the industry guideline. Specifically, lobe lengths can be longer than the industry guideline for STP cable and UTP level 5 cable at 4 Mb/s. See Table 2, Digital Lobe Length Guideline, for the maximum lobe lengths for Digital's MAUs. Also refer to either ªDEChub 900 MultiSwitch Configuration or DEChub ONE Configurationsº below for more configuration information.

Table 2 Digital Lobe Length Guideline1

Speed

UTP

 

STP

Level 3

 

Level 5

 

 

 

 

 

 

4 Mb/s

100 m (327 ft)

 

200 m (655 ft)

376 m (1235 ft)

16 Mb/s

65 m (213 ft)

 

100 m (327 ft)

173 m (569 ft)

 

 

 

 

 

1All distances include patch cables and hub connections.

Digital recommends that you keep lobe lengths within the maximums found in the industry guideline whenever possible. This allows for future network expansion and upgrade. When current needs dictate the longer lobe lengths, you can increase lobe lengths up to the maximums in Digital's guideline without any negative effect on the network.

DEChub 900 MultiSwitch Configuration

Multiple Hubs

A repeater is needed in each hub to connect hubs in a multiple hub network. Refer to the appropriate Token Ring repeater manual for specific information.

DEChub ONE Configurations

Unshielded Twisted-Pair Cable Configurations:

Multiple MAUs in One Wiring Closet at 16 Mb/s

At 16 Mb/s, a maximum of five MAUs can be in one wiring closet without affecting maximum lobe length. Subtract 10 meters from the lobe lengths in Table 2 for each additional MAU above five in a wiring closet.

Multiple Wiring Closets

Digital recommends that you use repeaters to segment the ring in a network with multiple wiring closets. In some situations, only one, or no repeaters, are required. Refer to the appropriate Token Ring repeater manual for specific information.

DECmau 900TL

11

Image 11
Contents DEChub ONE MAU 900TL InstallationEK±DTMAU±IN. A01 CopyrightFront Panel Rear Panel of DEChub ONE MAU 900TL Remove the single-slot hub if necessary Installing a MAU in a DEChub 900 MultiSwitchInstall the MAU in the hub Connect station cables Verify powerMount MAU optional Installing a DEChub ONE MAU 900TLSet Autowrap switches Connect power supplyCheck LEDs Install a MAU to adjacent MAUs or repeatersRemoving a MAU from a DEChub 900 MultiSwitch DEChub ONE only LED SummaryOff Flashing Hub MAU onlyCabling DEChub 900 MultiSwitch ConfigurationDEChub ONE Configurations Total Cable Budget for UTP Level 5 Cable at 4 Mb/s1 Cable Connector SpecificationsShielded Twisted-Pair Cable Configuration MAU Connector Signal NamesThen Do This DEChub 900 MultiSwitch and DEChub ONE Problem SolvingThen Do This DEChub 900 MultiSwitch only Associated Document Product SpecificationsProduct Specification A Hub DEChub ONE