Digicom ED-20 PPP ED-Tool for ED-20 commands, General commands, Cable is connected to

Page 17

8.1.1 ED-Tool for ED-20 commands

This section describes the ED-Tool for ED-20 commands. The commands are described by there use.

Details about allowed values and default values is described is section 6.2.

1

2

3

4

57600

RTS/CTS

5

6

8.1.1.1 General commands

1

 

Selects type of connection, Serial or over the Network.

 

 

If ‘Serial’ is selected, use the “Tools menu – Serial COM port” to

 

 

select which of COM1:, COM2:, COM3:, or COM4: your serial

 

 

cable is connected to.

2

Read Config

Reads configuration from the ED-20.

3

Write Config

Writes configuration to the ED-20.

 

 

Note! ED-20 must be rebooted before any new configuration

 

 

is activated.

4

Reboot

Reboots the ED-20.

8.1.1.2 Serial Interface – Channel 1 specific commands

5

Data Rate

Selects Data Rate for serial communication, ED-20 – Modem.

6

Flow Control

Selects if flow control is used or not.

 

 

Note! All interconnecting wires are required between the ED-20

 

 

and the attached modem.

6609-2221

17

Image 17
Contents 6609-2221 PPPContents Before installation, maintenance or modification work SafetyInstallation ApprovalsDeclaration of Conformity Declaration of conformityIntroduction Specification Indicators LED ConfigurationTransient Protection ApplicationMounting /Removal MaintenanceInstallation Received Data ConnectionsOut Transmitted Data CH2 RS-232 Connections, DCE CH1 RS-232 Connections, DCEPower LED Indicators From left to rightED-20 working mode Transmitted Data incoming serial dataDIP Swiches is not used in this product, leave as it is Factory settingsDIP Switch Settings MAC address Installation of ED-Tool for ED-20System Requirements MinimumFunctional description Application modeAbout PPP Network interfacesPPP connection Configuration modeBrouter function Firewall functionConfiguration by ED-Tool for ED-20 ConfigurationTypical configuration procedures Program StartGeneral commands ED-Tool for ED-20 commandsSerial Interface Channel 1 specific commands Selects type of connection, Serial or over the NetworkModem Settings 16 17 18 Modem Init Modem AT-CommandsModem Hangup Modem Connect Dial OutLogin Network SettingsPassword Set the login password PPP Network InterfaceBrouter Settings Brouter SettingsBrouter Mode Firewall Mode Firewall SettingsFirewall Settings IP AddressAllowed values None, RTS/CTS Default RTS/CTS Default 57 600 bit/sAllowed values LL, Pstn Default Pstn Allowed valuesDial IN/OUT Allowed values NO,YES Default noConnect at PWR on DCD ControlDefault 2 seconds Default +++Allowed values, 0, 1 to Default 0 function disabled Default AT&F&D0S0=0&K3+MS=V34&WDefault Ring Default ATHDefault Connect Allowed values Default Default ATAAllowed values NONE, PAP, Chap Default None UsernameLocal IP 0.0126.0.0.0 128.1.0.0 192.0.1.0 DefaultRemote address Subnet MaskDefault Off Refer to .2.2 General Modem settings and Dial IN/OUTBrouter Settings IP Address Firewall Settings IP AddressApplication examples Example of application with IP address settingsRemote connection LAN Dial LAN LAN Leased LineLAN LAN PSTN, Brouter, Firewall T03-03766609-222103.06 Mälartryck AB, Eskilstuna, Sweden

ED-20 PPP specifications

The Digicom ED-20 PPP is a sophisticated and versatile device designed to provide seamless communication solutions for both personal and professional use. As a cutting-edge platform for Point-to-Point Protocol (PPP), the ED-20 facilitates efficient data transmission over various communication networks, enhancing connectivity while ensuring security and reliability.

One of the main features of the Digicom ED-20 PPP is its robust support for multiple network technologies, including ISDN, dial-up, and broadband connections. This flexibility allows users to connect seamlessly to the internet or private networks, adapting to various scenarios and ensuring that they remain connected regardless of the circumstances. The ED-20's capability to support diverse communication methods makes it an ideal choice for businesses and individuals who require reliable data access.

The ED-20 excels in providing efficient data compression and error correction mechanisms. By employing advanced algorithms, it minimizes data payloads and enhances the speed of transmission. This feature is particularly beneficial for environments with limited bandwidth, as it allows users to optimize their data usage without sacrificing performance. The device’s ability to maintain high-speed communication even in challenging conditions highlights its technological prowess and adaptability.

Another hallmark of the Digicom ED-20 PPP is its easy-to-use interface and setup process. Designed with user experience in mind, the device requires minimal technical knowledge to configure and operate. This user-friendly approach ensures that even those unfamiliar with network technologies can benefit from its advanced features without a steep learning curve.

Security is paramount in today’s digital landscape, and the ED-20 PPP incorporates multiple security protocols to safeguard data transmission. By utilizing encryption and authentication techniques, the device ensures that sensitive information remains protected during transfer, making it an indispensable tool for organizations handling confidential data.

In terms of physical characteristics, the Digicom ED-20 PPP is compact and designed for portability, making it suitable for a variety of environments, including remote work settings and traveling professionals. Its durable construction guarantees longevity, while its lightweight design enhances mobility.

Overall, the Digicom ED-20 PPP stands out as a reliable and feature-rich solution for diverse communication needs, combining flexibility, efficiency, and security in a single device. Whether for business or personal use, the ED-20 effectively meets the demands of modern connectivity.