Digicom ED-20 PPP installation manual Default ATH, Default Connect, Default Ring

Page 26

Modem Hangup

Command

Hangup string that will be sent to the modem.

Default: ATH

Answer

Expected answer from the modem on the sent command.

Default: OK

Timeout

Define the time in seconds between the sent command and the expected answer before the command have failed.

Allowed values: 0 to 9999

Default: 3

Retries

Define the number of retries in case if a failed command.

Allowed values: 0 to 9999

Default: 1

Modem Connect (Dial Out)

Command

Dial out string that will be sent to the modem.

Default: ATDS=0 (dials the stored number in location 0, stored with AT&Z command)

Answer

Expected answer from the modem on the sent command.

Default: CONNECT

Timeout

Define the time in seconds between the sent command and the expected answer before the command have failed.

Allowed values: 0 to 9999

Default: 60

Retries

Define the number of retries in case if a failed command.

Allowed values: 0 to 9999

Default: 1

Modem Connect (Dial In)

Command

Dial in string that will be sent from the modem on an incoming call.

Default: RING

26

6609-2221

Image 26 Contents
PPP 6609-2221Contents Installation SafetyBefore installation, maintenance or modification work ApprovalsDeclaration of conformity Declaration of ConformityIntroduction Specification Transient Protection ConfigurationIndicators LED ApplicationMounting /Removal MaintenanceInstallation Received Data ConnectionsOut Transmitted Data CH1 RS-232 Connections, DCE CH2 RS-232 Connections, DCEED-20 working mode LED Indicators From left to rightPower Transmitted Data incoming serial dataDIP Swiches is not used in this product, leave as it is Factory settingsDIP Switch Settings System Requirements Installation of ED-Tool for ED-20MAC address MinimumAbout PPP Application modeFunctional description Network interfacesBrouter function Configuration modePPP connection Firewall functionTypical configuration procedures ConfigurationConfiguration by ED-Tool for ED-20 Program StartSerial Interface Channel 1 specific commands ED-Tool for ED-20 commandsGeneral commands Selects type of connection, Serial or over the NetworkModem Settings Modem Hangup Modem AT-Commands16 17 18 Modem Init Modem Connect Dial OutPassword Set the login password Network SettingsLogin PPP Network InterfaceBrouter Settings Brouter SettingsBrouter Mode Firewall Settings Firewall Settings Firewall Mode IP AddressAllowed values LL, Pstn Default Pstn Default 57 600 bit/sAllowed values None, RTS/CTS Default RTS/CTS Allowed valuesConnect at PWR on Allowed values NO,YES Default noDial IN/OUT DCD ControlAllowed values, 0, 1 to Default 0 function disabled Default +++Default 2 seconds Default AT&F&D0S0=0&K3+MS=V34&WDefault Ring Default ATHDefault Connect Allowed values NONE, PAP, Chap Default None Default ATAAllowed values Default UsernameRemote address 0.0126.0.0.0 128.1.0.0 192.0.1.0 DefaultLocal IP Subnet MaskBrouter Settings IP Address Refer to .2.2 General Modem settings and Dial IN/OUTDefault Off Firewall Settings IP AddressRemote connection LAN Dial Example of application with IP address settingsApplication examples LAN LAN Leased LineLAN LAN PSTN, Brouter, Firewall T03-03766609-222103.06 Mälartryck AB, Eskilstuna, Sweden